Your browser doesn't support javascript.
loading
Use of MALDI-MS Combined with Differential Hydrogen-Deuterium Exchange for Semiautomated Protein Global Conformational Screening.
Pirrone, Gregory F; Wang, Heather; Canfield, Nicole; Chin, Alexander S; Rhodes, Timothy A; Makarov, Alexey A.
Afiliación
  • Pirrone GF; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
  • Wang H; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
  • Canfield N; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
  • Chin AS; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
  • Rhodes TA; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
  • Makarov AA; Merck & Co., Inc., MRL , †Process Research & Development and ‡Pharmaceutical Sciences, 126 East Lincoln Avenue, Rahway, New Jersey 07065, United States.
Anal Chem ; 89(16): 8351-8357, 2017 08 15.
Article en En | MEDLINE | ID: mdl-28727449
ABSTRACT
Matrix-assisted laser desorption/ionization (MALDI) coupled with a time-of-flight (TOF) mass-spectrometry (MS) detector is acknowledged to be very useful for analysis of biological molecules. At the same time, hydrogen-deuterium exchange (HDX) is a well-known technique for studying protein higher-order structure. However, coupling MALDI with HDX has been challenging because of undesired back-exchange reactions during analysis. In this report, we survey an approach that utilizes MALDI coupled with an automated sample preparation to compare global conformational changes of proteins under different solution conditions using differential HDX. A nonaqueous matrix was proposed for MALDI sample preparation to minimize undesirable back-exchange. An automated experimental setup based on the use of a liquid-handling robot and automated data acquisition allowed for tracking protein conformational changes as a difference in the number of protons exchanged to deuterons at specified solution conditions. Experimental time points to study the deuteration-labeling kinetics were obtained in a fully automated manner. The use of a nonaqueous matrix solution allowed experimental error to be minimized to within 1% RSD. We applied this newly developed MALDI-HDX workflow to study the effect of several common excipients on insulin folding stability. The observed results were corroborated by literature data and were obtained in a high-throughput and automated manner. The proposed MALDI-HDX approach can also be applied in a high-throughput manner for batch-to-batch higher-order structure comparison, as well as for the optimization of protein chemical modification reactions.