Your browser doesn't support javascript.
loading
MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.
Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian.
Afiliación
  • Chen KT; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Salcedo S; Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Chonde DB; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Izquierdo-Garcia D; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Levine MA; Program in Biophysics, Harvard University, Boston, Massachusetts, USA.
  • Price JC; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Dickerson BC; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Catana C; Program in Biophysics, Harvard University, Boston, Massachusetts, USA.
J Magn Reson Imaging ; 48(5): 1288-1296, 2018 11.
Article en En | MEDLINE | ID: mdl-29517819
ABSTRACT

BACKGROUND:

Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners.

PURPOSE:

To assess the effect of realistic head motion and MR-based MC on static [18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. STUDY TYPE Observational study. POPULATION Thirty dementia subjects were recruited. FIELD STRENGTH/SEQUENCE 3T hybrid PET/MR scanner where EPI-based and T1 -weighted sequences were acquired simultaneously with the PET data. ASSESSMENT Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. STATISTICAL TESTS The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level.

RESULTS:

MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs was also decreased using MR-based MC. All comparisons were significant at the P = 0.05 level. DATA

CONCLUSION:

Incorporating temporally correlated MR data to account for intraframe motion has a positive impact on the FDG PET image quality and data quantification in dementia patients. LEVEL OF EVIDENCE 3 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2018;471288-1296.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Encéfalo / Imagen por Resonancia Magnética / Demencia / Tomografía de Emisión de Positrones / Imagen Multimodal Tipo de estudio: Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Encéfalo / Imagen por Resonancia Magnética / Demencia / Tomografía de Emisión de Positrones / Imagen Multimodal Tipo de estudio: Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos