Your browser doesn't support javascript.
loading
Cross-sectional area and fat content in dachshund epaxial muscles: an MRI and CT reliability study.
Boström, Anna Fredrika; Lappalainen, Anu K; Danneels, Lieven; Jokinen, Tarja S; Laitinen-Vapaavuori, Outi; Hielm-Björkman, Anna K.
Afiliación
  • Boström AF; Small Animal Surgery, Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Lappalainen AK; Small Animal Surgery, Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Danneels L; Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium.
  • Jokinen TS; Small Animal Surgery, Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Laitinen-Vapaavuori O; Small Animal Surgery, Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Hielm-Björkman AK; Small Animal Surgery, Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
Vet Rec Open ; 5(1): e000256, 2018.
Article en En | MEDLINE | ID: mdl-29632671
ABSTRACT
MRI and CT are frequently used to diagnose spinal diseases in dogs. These modalities have detected epaxial muscle degeneration in dachshunds with intervertebral disc herniation. However, research on the reliability of epaxial muscular measurements is limited in veterinary medicine. The aims of the study were to assess the intrarater and inter-rater reliability of epaxial muscle cross-sectional area (CSA) and fat content measurements on MRI and CT images in dachshunds, and to compare the CSA measurement between the two modalities. MRI and CT images of 10 healthy dachshunds were evaluated. Two blinded observers assessed MRI CSA, MRI fat content, CT CSA and CT muscle attenuation of three thoracolumbar epaxial muscles using OsiriX. The results showed 'substantial' to 'almost perfect' intrarater reliability (intraclass correlation coefficient (ICC) 0.828-0.998) and inter-rater reliability (ICC 0.685-0.854) for all variables. When individual spinal segments were analysed, the intrarater and inter-rater reliability decreased and the confidence intervals increased. There was positive correlation (r= 0.719-0.841, P=0.001) and high agreement (0.824-0.894) for the measured CSA between MRI and CT. Epaxial muscle CSA and fat content can be reliably measured on MRI and CT, bearing in mind that measurement of certain segments requires adequate training.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prevalence_studies Idioma: En Revista: Vet Rec Open Año: 2018 Tipo del documento: Article País de afiliación: Finlandia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prevalence_studies Idioma: En Revista: Vet Rec Open Año: 2018 Tipo del documento: Article País de afiliación: Finlandia