Your browser doesn't support javascript.
loading
Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.
Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M.
Afiliación
  • Satriano A; Stephenson Cardiac Imaging Centre, University of Calgary, Calgary, Alberta, Canada.
  • Guenther Z; Division of Cardiology, Department of Cardiac Sciences, Libin Cardiovascular Institute of Alberta, University of Calgary, South Health Campus, 4448 Front Street SE, Calgary, Alberta, T3M 1M4, Canada.
  • White JA; Stephenson Cardiac Imaging Centre, University of Calgary, Calgary, Alberta, Canada.
  • Merchant N; Department of Diagnostic Imaging, Cummings School of Medicine, University of Calgary, Calgary, Alberta, Canada.
  • Di Martino ES; Stephenson Cardiac Imaging Centre, University of Calgary, Calgary, Alberta, Canada.
  • Al-Qoofi F; Division of Cardiology, Department of Cardiac Sciences, Libin Cardiovascular Institute of Alberta, University of Calgary, South Health Campus, 4448 Front Street SE, Calgary, Alberta, T3M 1M4, Canada.
  • Lydell CP; Stephenson Cardiac Imaging Centre, University of Calgary, Calgary, Alberta, Canada.
  • Fine NM; Department of Diagnostic Imaging, Cummings School of Medicine, University of Calgary, Calgary, Alberta, Canada.
BMC Cardiovasc Disord ; 18(1): 76, 2018 05 02.
Article en En | MEDLINE | ID: mdl-29720088
ABSTRACT

BACKGROUND:

Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR).

METHODS:

Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed.

RESULTS:

The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively.

CONCLUSIONS:

Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta Torácica / Válvula Aórtica / Estenosis de la Válvula Aórtica / Aortografía / Imagenología Tridimensional / Electrocardiografía / Técnicas de Imagen Sincronizada Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter / Angiografía por Tomografía Computarizada / Hemodinámica Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta Torácica / Válvula Aórtica / Estenosis de la Válvula Aórtica / Aortografía / Imagenología Tridimensional / Electrocardiografía / Técnicas de Imagen Sincronizada Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter / Angiografía por Tomografía Computarizada / Hemodinámica Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Canadá