Short-term repeatability of myocardial blood flow using 82Rb PET/CT: The effect of arterial input function position and motion correction.
Otaki, Yuka; Lassen, Martin Lyngby; Manabe, Osamu; Eisenberg, Evann; Gransar, Heidi; Wang, Frances; Lee, Yoon Jae; Tzolos, Evangelos; Berman, Daniel S; Slomka, Piotr J.
Afiliación
  • Otaki Y; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Lassen ML; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Manabe O; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Eisenberg E; Department of Nuclear Medicine, Hokkaido University of Graduate School of Medicine, Sapporo, Japan.
  • Gransar H; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Wang F; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Lee YJ; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Tzolos E; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Berman DS; Department of Imaging and Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Ste. A047N, Los Angeles, CA, 90048, USA.
  • Slomka PJ; Centre for Cardiovascular Sciences, University of Edinburgh, Chancellors Building, 49 Little France Crescent, Edinburgh, EH16 4SB, UK.
J Nucl Cardiol ; 28(4): 1718-1725, 2021 Aug.
Article en En | MEDLINE | ID: mdl-31559536
BACKGROUND: We tested the repeatability of myocardial blood flow (MBF) quantified using 82Rb with and without motion correction (MC) and with arterial input functions estimated from left ventricle (LV) and atrium (LA). METHODS: Twenty-one patients referred for clinical 82Rb PET/CT underwent repeated rest scans in a single imaging session. Global MBF was quantified using three different assessments by two operators: (1) automatic processing without MC and LV arterial input function (AIF), (2) with MC and LV-AIF, and (3) with MC and LA-AIF. Inter-scan and inter-operator repeatability were tested using coefficient of variation (CV). RESULTS: MC with LV-AIF did not change MBF (no MC: 1.01 ± 0.30 mL/min/g vs MC with LV-AIF: 1.01 ± 0.29, P = 0.70), whereas MC with LA-AIF showed significantly lower MBF assessments (0.95 ± 0.28 mL/min/g, P = 0.0006). We report significant improvement for test-retest reproducibility for global MBF following MC (CV; No MC: 16.0, MC (LV-AIF): 9.2, MC (LA-AIF): 8.8). Good inter-operator repeatability was observed for LV-AIF (CV = 4.7) and LA-AIF (CV = 5.6) for global MBF assessments. CONCLUSIONS: MC significantly improved the test-retest repeatability between operators and between scans. MBF obtained after MC with LV-AIF were comparable, whereas MBFs after MC and LA-AIF were significantly reduced.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Procesamiento de Imagen Asistido por Computador / Circulación Coronaria / Imagen de Perfusión Miocárdica / Tomografía Computarizada por Tomografía de Emisión de Positrones Límite: Aged / Female / Humans / Male Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Procesamiento de Imagen Asistido por Computador / Circulación Coronaria / Imagen de Perfusión Miocárdica / Tomografía Computarizada por Tomografía de Emisión de Positrones Límite: Aged / Female / Humans / Male Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos