Your browser doesn't support javascript.
loading
The sub-millisievert era in CTCA: the technical basis of the new radiation dose approach.
Schicchi, Nicolò; Fogante, Marco; Palumbo, Pierpaolo; Agliata, Giacomo; Esposto Pirani, Paolo; Di Cesare, Ernesto; Giovagnoni, Andrea.
Afiliación
  • Schicchi N; Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
  • Fogante M; Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy. marco.fogante89@gmail.com.
  • Palumbo P; Radiology Department, Azienda Ospedaliero Universitaria "San Salvatore", 60126, L'Aquila, Italy.
  • Agliata G; Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
  • Esposto Pirani P; Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
  • Di Cesare E; Radiology Department, Azienda Ospedaliero Universitaria "San Salvatore", 60126, L'Aquila, Italy.
  • Giovagnoni A; Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
Radiol Med ; 125(11): 1024-1039, 2020 Nov.
Article en En | MEDLINE | ID: mdl-32930945
ABSTRACT
Computed tomography coronary angiography (CTCA) has become a cornerstone in the diagnostic process of the heart disease. Although the cardiac imaging with interventional procedures is responsible for approximately 40% of the cumulative effective dose in medical imaging, a relevant radiation dose reduction over the last decade was obtained, with the beginning of the sub-mSv era in CTCA. The main technical basis to obtain a radiation dose reduction in CTCA is the use of a low tube voltage, the adoption of a prospective electrocardiogram-triggering spiral protocol and the application of the tube current modulation with the iterative reconstruction technique. Nevertheless, CTCA examinations are characterized by a wide range of radiation doses between different radiology departments. Moreover, the dose exposure in CTCA is extremely important because the benefit-risk calculus in comparison with other modalities also depends on it. Finally, because anatomical evaluation not adequately predicts the hemodynamic relevance of coronary stenosis, a low radiation dose in routine CTCA would allow the greatest use of the myocardial CT perfusion, fractional flow reserve-CT, dual-energy CT and artificial intelligence, to shift focus from morphological assessment to a comprehensive morphological and functional evaluation of the stenosis. Therefore, the aim of this work is to summarize the correct use of the technical basis in order that CTCA becomes an established examination for assessment of the coronary artery disease with low radiation dose.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Enfermedad de la Arteria Coronaria / Angiografía Coronaria / Exposición a la Radiación / Angiografía por Tomografía Computarizada Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Radiol Med Año: 2020 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Enfermedad de la Arteria Coronaria / Angiografía Coronaria / Exposición a la Radiación / Angiografía por Tomografía Computarizada Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Radiol Med Año: 2020 Tipo del documento: Article País de afiliación: Italia