Your browser doesn't support javascript.
loading
Sanger sequencing is no longer always necessary based on a single-center validation of 1109 NGS variants in 825 clinical exomes.
Arteche-López, A; Ávila-Fernández, A; Romero, R; Riveiro-Álvarez, R; López-Martínez, M A; Giménez-Pardo, A; Vélez-Monsalve, C; Gallego-Merlo, J; García-Vara, I; Almoguera, Berta; Bustamante-Aragonés, A; Blanco-Kelly, F; Tahsin-Swafiri, S; Rodríguez-Pinilla, E; Minguez, P; Lorda, I; Trujillo-Tiebas, M J; Ayuso, C.
Afiliación
  • Arteche-López A; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Ávila-Fernández A; Department of Genetics, University Hospital, 12 de Octubre, Madrid, Spain.
  • Romero R; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Riveiro-Álvarez R; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • López-Martínez MA; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Giménez-Pardo A; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Vélez-Monsalve C; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Gallego-Merlo J; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • García-Vara I; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Almoguera B; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Bustamante-Aragonés A; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Blanco-Kelly F; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Tahsin-Swafiri S; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Rodríguez-Pinilla E; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Minguez P; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Lorda I; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Trujillo-Tiebas MJ; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
  • Ayuso C; Department of Genetics, Health Research Institute-Jimenez Diaz Foundation University Hospital (IIS-FJD), Avda. Reyes Católicos 2, 28040, Madrid, Spain.
Sci Rep ; 11(1): 5697, 2021 03 11.
Article en En | MEDLINE | ID: mdl-33707547
Despite the improved accuracy of next-generation sequencing (NGS), it is widely accepted that variants need to be validated using Sanger sequencing before reporting. Validation of all NGS variants considerably increases the turnaround time and costs of clinical diagnosis. We comprehensively assessed this need in 1109 variants from 825 clinical exomes, the largest sample set to date assessed using Illumina chemistry reported. With a concordance of 100%, we conclude that Sanger sequencing can be very useful as an internal quality control, but not so much as a verification method for high-quality single-nucleotide and small insertion/deletions variants. Laboratories might validate and establish their own thresholds before discontinuing Sanger confirmation studies. We also expand and validate 23 copy number variations detected by exome sequencing in 20 samples, observing a concordance of 95.65% (22/23).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Secuenciación de Nucleótidos de Alto Rendimiento / Exoma / Mutación Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Secuenciación de Nucleótidos de Alto Rendimiento / Exoma / Mutación Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: España