Your browser doesn't support javascript.
loading
Finite element modelling of the surgical procedure for placement of a straight electrode array: Mechanical and clinical consequences.
Areias, B; Parente, M P L; Gentil, F; Natal Jorge, R M.
Afiliación
  • Areias B; INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal. Electronic address: bareias@fe.up.pt.
  • Parente MPL; INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal; FEUP, Faculty of Engineering, University of Porto, Porto, Portugal. Electronic address: mparente@fe.up.pt.
  • Gentil F; Escola Superior de Saúde - Politécnico do Porto, Porto, Portugal; Clínica ORL - Dr. Eurico de Almeida, Porto, Portugal; WIDEX, Porto, Portugal. Electronic address: fernanda.fgnanda@gmail.com.
  • Natal Jorge RM; INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal; FEUP, Faculty of Engineering, University of Porto, Porto, Portugal. Electronic address: rnatal@fe.up.pt.
J Biomech ; 129: 110812, 2021 12 02.
Article en En | MEDLINE | ID: mdl-34688063
ABSTRACT
A cochlear implant is an electronic device implanted into the cochlea to directly stimulate the auditory nerve. Such device is used in patients with severe-to-profound hearing loss. The cochlear implant surgery is safe, but involves some risks, such as infections, device malfunction or damage of the facial nerve and it can result on a poor hearing outcome, due to the destruction of any present residual hearing. Future improvements in cochlear implant surgery will necessarily involve the decrease of the intra-cochlear damage. Several implant related variables, such as materials, geometrical design, processor and surgical techniques can be optimized in order for the patients to partially recover their hearing capacities The straight electrode is a type of cochlear implant that many authors indicate as being the less traumatic. From the finite element analysis conducted in this work, the influence of the insertion speed, the friction coefficient between the cochlear wall and the electrode array, and several configurations of the cochlear implant tip were studied. The numerical simulations of the implantation showed the same pattern of the insertion force against insertion depth, thus indicating the different phases of the insertion. Results demonstrated that lower insertion speeds, friction coefficients and tip stiffness, led to a reduction on the contact pressures and insertion force. It is expected that these improved configurations will allow to preserve the residual hearing while reducing surgical complications.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Implantes Cocleares / Implantación Coclear Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Biomech Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Implantes Cocleares / Implantación Coclear Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Biomech Año: 2021 Tipo del documento: Article