Your browser doesn't support javascript.
loading
Knee disarticulation following oncologic total knee arthroplasty: A 5-year follow-up case report.
Einfeldt, Ann-Kathrin; Yao, Dawei; Daniilidis, Kiriakos; Calliess, Tilman; Welke, Bastian; Jakubowitz, Eike.
Afiliación
  • Einfeldt AK; Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.
  • Yao D; Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.
  • Daniilidis K; Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany; Orthopedic Traumatology Center Regensburg, Joseph-Dahlem-Straße 7, 93049 Regensburg, Germany.
  • Calliess T; Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany; Salem-Spital, Schänzlistrasse 39, Bern, Switzerland.
  • Welke B; Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.
  • Jakubowitz E; Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany. Electronic address: Jakubowitz.Eike@mh-hannover.de.
Clin Biomech (Bristol, Avon) ; 94: 105608, 2022 04.
Article en En | MEDLINE | ID: mdl-35248833
BACKGROUND: The present case report describes the 5-year follow-up results of an atypical knee disarticulation of a man previously treated with an oncologic total knee arthroplasty due to an Ewing sarcoma. METHODS: The patient presented an aseptic loosened tibial component of a tumor prosthesis system and requested final amputation, as he had previously suffered from five revision surgeries. To encourage the most functional outcome regarding an exoskeletal prosthesis, we decided to disarticulate the knee joint while retaining the currently fixed femoral component to create a full end-bearing stump. FINDINGS: The patient could be mobilized as a functional knee disarticulated amputee. Seven months after amputation, he showed a slightly less symmetrical gait compared to the preoperative status (preoperative mean Symmetry Index: 0.984 for kinematics and 0.940 for kinetics, 7-month postoperative Symmetry Index: 0.858 and 0.915). At the 5-year follow-up, the femoral component is still stably fixated and shows no loosening signs. In addition, the Symmetry Index increased to 0.908 and 0.949. INTERPRETATION: Even after 5 years, the presented amputation appears to be consistent with "conventional" knee disarticulation. The femoral component still withstands the altered loads and the patient shows a further improved gait pattern.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla Tipo de estudio: Observational_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla Tipo de estudio: Observational_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania