Your browser doesn't support javascript.
loading
The Impact of Radiofrequency Wide Circumferential Pulmonary Vein Isolation on Left Atrial Geometry in Patients with Recurrent Atrial Fibrillation.
Iliodromitis, Konstantinos E; Silva, Etel; Van Camp, Guy; Geelen, Peter; De Potter, Tom.
Afiliación
  • Iliodromitis KE; Department of Cardiology, Cardiovascular Center OLV, Aalst, Belgium, konstantinos.iliodromitis@gmail.com.
  • Silva E; Department of Cardiology, Cardiovascular Center OLV, Aalst, Belgium.
  • Van Camp G; Department of Cardiology, Cardiovascular Center OLV, Aalst, Belgium.
  • Geelen P; Department of Cardiology, Cardiovascular Center OLV, Aalst, Belgium.
  • De Potter T; Department of Cardiology, Cardiovascular Center OLV, Aalst, Belgium.
Cardiology ; 147(4): 436-442, 2022.
Article en En | MEDLINE | ID: mdl-35661073
ABSTRACT

PURPOSE:

The aim of the study was to investigate the effect of wide area circumferential radiofrequency catheter ablation (WACA) pulmonary vein isolation on left atrium (LA) geometry.

METHODS:

Seventy-one patients underwent WACA, for recurrent paroxysmal (n = 31) and persistent (n = 40) atrial fibrillation (AF). A three-dimension rotational angiography of the LA was obtained immediately prior to index and repeat procedure.

RESULTS:

Significant reduction of LA volume (65.6 ± 14 mL/m2 vs. 62.2 ± 15 mL/m2, p < 0.001) and surface (74.4 ± 11.2 vs. 70.4 ± 11.2 cm2/m2, p < 0.001) was noted. LA sphericity increased significantly (82 ± 2% vs. 83 ± 2%, p = 0.004) in all 71 patients. Patients with paroxysmal AF showed significant reduction of LA volume (121.8 ± 25.7 vs. 116 ± 32 mL, p = 0.008) and increase of LA sphericity (82.3 ± 2.1 vs. 83.1 ± 2%, p = 0.009). Patients with persistent AF showed significant decrease of LA volume (133.5 ± 32 vs. 126 ± 32 mL, p = 0.005) and LA surface area (76.3 ± 12.3 vs. 71.8 ± 12.4 cm2/m2, p = 0.005). LA sphericity (82.4 ± 2.8 vs. 83 ± 2.4%, p = ns) remained unchanged.

CONCLUSIONS:

WACA results into significant reduction of LA volume and surface area. Increased LA sphericity is observed in paroxysmal AF only.