Your browser doesn't support javascript.
loading
MR multitasking-based dynamic imaging for cerebrovascular evaluation (MT-DICE): Simultaneous quantification of permeability and leakage-insensitive perfusion by dynamic T 1 / T 2 * mapping.
Hu, Zhehao; Christodoulou, Anthony G; Wang, Nan; Xie, Yibin; Shiroishi, Mark S; Yang, Wensha; Zada, Gabriel; Chow, Frances E; Margol, Ashley S; Tamrazi, Benita; Chang, Eric L; Li, Debiao; Fan, Zhaoyang.
Afiliación
  • Hu Z; Department of Radiology, University of Southern California, Los Angeles, California, USA.
  • Christodoulou AG; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Wang N; Department of Bioengineering, University of California, Los Angeles, California, USA.
  • Xie Y; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Shiroishi MS; Department of Bioengineering, University of California, Los Angeles, California, USA.
  • Yang W; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Zada G; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Chow FE; Department of Radiology, University of Southern California, Los Angeles, California, USA.
  • Margol AS; Department of Radiation Oncology, University of Southern California, Los Angeles, California, USA.
  • Tamrazi B; Department of Neurosurgery, University of Southern California, Los Angeles, California, USA.
  • Chang EL; Department of Neurosurgery, University of Southern California, Los Angeles, California, USA.
  • Li D; Department of Neuro-oncology, Children's Hospital Los Angeles, Los Angeles, California, USA.
  • Fan Z; Department of Radiology, Children's Hospital Los Angeles, Los Angeles, California, USA.
Magn Reson Med ; 89(1): 161-176, 2023 Jan.
Article en En | MEDLINE | ID: mdl-36128892

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Medios de Contraste Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Medios de Contraste Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos