Your browser doesn't support javascript.
loading
First divertor Thomson scattering measurements on MAST-U.
Clark, J G; Bowden, M D; Kim, Y; Parry, B; Rose, E; Sarwar, R; Scannell, R.
Afiliación
  • Clark JG; Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3BX, United Kingdom.
  • Bowden MD; Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3BX, United Kingdom.
  • Kim Y; UKAEA/CCFE, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United Kingdom.
  • Parry B; UKAEA/CCFE, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United Kingdom.
  • Rose E; UKAEA/CCFE, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United Kingdom.
  • Sarwar R; UKAEA/CCFE, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United Kingdom.
  • Scannell R; UKAEA/CCFE, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United Kingdom.
Rev Sci Instrum ; 93(10): 103534, 2022 Oct 01.
Article en En | MEDLINE | ID: mdl-36319361
ABSTRACT
MAST-U is equipped with a Super-X divertor, which aims to reduce heat flux to the target and promote detachment. Measurements of plasma electron density and temperature in the Super-X chamber offer insight into the processes at work in this type of divertor. First data have been obtained from the MAST-U divertor Thomson scattering diagnostic designed to measure these quantities. Following a Raman scattering calibration in nitrogen, the diagnostic operated over a number of plasma pulses in the first physics campaign. Electron density and temperature measurements have been taken in attached and detached conditions as the strike leg moved through the field of view of the diagnostic. The system operated with a dedicated 30 Hz laser with timing synchronized to seven similar lasers installed in the core Thomson system. Electron densities in the range of 1 × 1018-5 × 1019 m-3 have been measured by the system throughout these regimes. Although the system was specified to measure from 1 to 40 eV, electron temperatures in the Super-X divertor in the first campaign were low, and measurement down to 0.5 eV has been critical, particularly close to the detachment front. This generation of polychromator has been designed with increased stray light rejection compared to those used in the core system. This has proved successful with very low levels of stray light observed.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido