Your browser doesn't support javascript.
loading
EVALUATION OF OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT USING A FINGER CUFF IN ANESTHETIZED CHIMPANZEES (PAN TROGLODYTES).
Cassady, Katherine R; Balko, Julie A; Bailey, Kate M; Posner, Lysa P; Robertson, James B; Minter, Larry J.
Afiliación
  • Cassady KR; Department of Molecular Biomedical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA.
  • Balko JA; Department of Molecular Biomedical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA, jabalko@ncsu.edu.
  • Bailey KM; Department of Molecular Biomedical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA.
  • Posner LP; Department of Molecular Biomedical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA.
  • Robertson JB; Office of Research, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA.
  • Minter LJ; Department of Clinical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, NC 27606, USA.
J Zoo Wildl Med ; 54(1): 16-22, 2023 Mar.
Article en En | MEDLINE | ID: mdl-36971624
ABSTRACT
Cardiovascular disease is common among chimpanzees (Pan troglodytes), and serial blood pressure monitoring in conscious animals may improve disease surveillance and guide hypertension treatment strategies. The objective of this study was to compare the accuracy of a noninvasive, oscillometric blood pressure monitor using a finger blood pressure cuff with invasively measured blood pressure in anesthetized chimpanzees. Twelve chimpanzees were anesthetized with tiletamine-zolazepam intramuscularly, intubated, and maintained on inhaled isoflurane to effect. Blood pressure measurements, which included systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP), were collected simultaneously from an oscillometric blood pressure cuff placed on a forelimb digit (FBP) and a direct arterial catheter (IBP) every 5-10 min while anesthetized. One hundred paired samples were collected, and results were compared using Bland-Altman plots and analysis. FBP showed good agreement with IBP for SAP, MAP, and DAP but consistently overestimated values compared with IBP. FBP may be useful for serial blood pressure monitoring in conscious chimpanzees.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pan troglodytes / Isoflurano Límite: Animals Idioma: En Revista: J Zoo Wildl Med Asunto de la revista: MEDICINA VETERINARIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pan troglodytes / Isoflurano Límite: Animals Idioma: En Revista: J Zoo Wildl Med Asunto de la revista: MEDICINA VETERINARIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos