Your browser doesn't support javascript.
loading
Applying Automation and High-Throughput MALDI Mass Spectrometry for Peptide Metabolic Stability Screening.
Yao, Huifang; Chen, Bingming; Harradine, Paul; Habulihaz, Bahanu; McLaren, David G; Cancilla, Mark T.
Afiliación
  • Yao H; Department of Quantitative Biosciences, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
  • Chen B; Department of Preclinical Development, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
  • Harradine P; Department of Preclinical Development, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
  • Habulihaz B; Department of Preclinical Development, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
  • McLaren DG; Department of Quantitative Biosciences, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
  • Cancilla MT; Department of Preclinical Development, Merck & Co., Inc., 126 East Lincoln Avenue, P.O. Box 2000, Rahway, New Jersey 07065, United States.
J Am Soc Mass Spectrom ; 34(6): 1196-1200, 2023 Jun 07.
Article en En | MEDLINE | ID: mdl-37195067
The discovery of peptide therapeutics represents a fast-growing segment of pharmaceutical research. During the early discovery process, a large number of peptide candidates needs to be rapidly screened for metabolic stability in relevant biological matrices. In most cases, peptide stability assays are quantified using LC-MS/MS, which may take hours to analyze 384 samples and generates liters of solvent waste. Herein, we introduce a high-throughput screening (HTS) platform for peptide stability assessment founded on Matrix Assisted Laser Desorption/Ionization (MALDI) mass spectrometry (MS). Full automation has been implemented for sample preparation with minimal manual intervention. The limit of detection, linearity, and reproducibility of the platform were evaluated, and metabolic stabilities have been determined for a number of peptide candidates. The MALDI-MS-based HTS workflow is able to analyze 384 samples in less than 1 h while only using 115 µL of total solvent. Although this process allows for very rapid assessment of peptide stability, given the nature of the MALDI process, it is noteworthy that spot-to-spot variations and ionization bias are observed. Therefore, LC-MS/MS may still be needed for confident, quantitative measurements and/or when the ionization efficiency of certain peptides is inadequate using MALDI.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Péptidos / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies / Guideline / Screening_studies Idioma: En Revista: J Am Soc Mass Spectrom Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Péptidos / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies / Guideline / Screening_studies Idioma: En Revista: J Am Soc Mass Spectrom Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos