OBJECTIVE:
To investigate the safety and effectiveness of implanting temporary pacemakers using ultrasound-guidance at the bedside for rescuing patients in case of cardiac emergencies.METHODS:
We enrolled 194 patients with cardiac emergencies requiring temporary pacemakers in this study, and randomly assigned them to either a bedside ultrasound-guided installation group or an electrocardiogram-guided installation group. There were 105 cases in the bedside ultrasound-guided installation group, aged approximately 66.3 ± 10.2 years, and 89 cases in the electrocardiogram-guided installation group, aged approximately 65.8 ± 9.5 years old, and disease composition was similar between the two groups. We then compared the duration of the procedure, success rates, and occurrence of adverse events between the two groups.RESULTS:
The two groups showed similar clinical characteristics. The success rates of venipuncture and temporary pacemaker electrode placement were both 100% in the bedside ultrasound-guided installation group, compared to 87.8% and 96.7% respectively, in the electrocardiogram-guided installation group, with a statistically significant difference between the two groups. The duration of puncture was significantly shorter in the bedside ultrasound-guided installation group than in the electrocardiogram-guided installation group, with statistically significant differences. Moreover, no adverse events such as hematoma, pneumothorax and electrode dislodgement occurred in the bedside ultrasound-guided installation group, while 13 cases in the electrocardiogram-guided installation group experienced adverse events, and the difference was statistically significant.CONCLUSIONS:
The bedside installation of temporary pacemakers using ultrasound guidance is a simple, safe, effective, and cost-efficient procedure that boasts a high success rate, does not involve radiation, and enables accurate placement of the electrode catheter.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Marcapaso Artificial
/
Urgencias Médicas
Tipo de estudio:
Clinical_trials
/
Guideline
Límite:
Aged
/
Humans
/
Middle aged
Idioma:
En
Revista:
Ann Noninvasive Electrocardiol
Asunto de la revista:
CARDIOLOGIA
Año:
2023
Tipo del documento:
Article
País de afiliación:
China