Your browser doesn't support javascript.
loading
Shape-Configurable Mesh for Hernia Repair by Synchronizing Anisotropic Body Motion.
Ha, Hyunsu; Lee, Chan Hee; Lee, Kang Suk; Lee, Kyubae; Park, Jeongeun; Kim, Si Yeong; Baek, Sewoom; Kang, Mi-Lan; Lee, Dong Won; Sung, Hak-Joon.
Afiliación
  • Ha H; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Lee CH; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Lee KS; TMD LAB Co. Ltd., 6th floor, 31, Gwangnaru-ro 8-gil, Seongdong-gu, Seoul, 04799, Republic of Korea.
  • Lee K; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Park J; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Kim SY; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Baek S; Department of Brain Korea 21 FOUR Project for Medical Science and Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Kang ML; TMD LAB Co. Ltd., 6th floor, 31, Gwangnaru-ro 8-gil, Seongdong-gu, Seoul, 04799, Republic of Korea.
  • Lee DW; Department of Plastic and Reconstructive Surgery, Institute for Human Tissue Restoration, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea.
  • Sung HJ; Department of Medical Engineering, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Small ; 19(47): e2303325, 2023 Nov.
Article en En | MEDLINE | ID: mdl-37490554
ABSTRACT
Continuous progress has been made in elucidating the relationship between material property, device design, and body function to develop surgical meshes. However, an unmet need still exists wherein the surgical mesh can handle the body motion and thereby promote the repair process. Here, the hernia mesh design and the advanced polymer properties are tailored to synchronize with the anisotropic abdominal motion through shape configuration. The thermomechanical property of shape configurable polymer enables molding of mesh shape to fit onto the abdominal structure upon temperature shift, followed by shape fixing with the release of the heat energy. The microstructural design of mesh is produced through finite element modeling to handle the abdominal motion efficiently through the anisotropic longitudinal and transverse directions. The design effects are validated through in vitro, ex vivo, and in vivo mechanical analyses using a self-configurable, body motion responsive (BMR) mesh. The regenerative function of BMR mesh leads to effective repair in a rat hernioplasty model by effectively handling the anisotropic abdomen motion. Subsequently, the device-tissue integration is promoted by promoting healthy collagen synthesis with fibroblast-to-myofibroblast differentiation. This study suggests a potential solution to promote hernia repair by fine-tuning the relationship between material property and mesh design.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hernia Abdominal Límite: Animals Idioma: En Revista: Small Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hernia Abdominal Límite: Animals Idioma: En Revista: Small Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article