Novel radiologic indices for stem type decision in total hip arthroplasty in patients with metaphyseo-diaphyseal mismatched Dorr A proximal femur.
Lee, Han Jin; Kim, Hong Seok; Yoo, Jeong Joon.
Afiliación
  • Lee HJ; Department of Orthopaedic Surgery, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
  • Kim HS; Department of Orthopaedic Surgery, Hanil General Hospital, Seoul, Korea.
  • Yoo JJ; Department of Orthopaedic Surgery, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
BMC Musculoskelet Disord ; 25(1): 124, 2024 Feb 09.
Article en En | MEDLINE | ID: mdl-38336653
ABSTRACT

BACKGROUND:

In metaphyseo-diaphyseal (M-D) mismatched Dorr A femurs, it is difficult to achieve proper fixation with a type 1 stem. Proper interpretation of the geometry of the femur is integral at the preoperative stage in an M-D mismatched femur, but there has been a scarcity of studies on the radiologic indices. Therefore, we analyze the previous radiologic indices and suggest the novel ones for M-D mismatched femurs.

METHODS:

Our study was a retrospective review of preoperative radiographs of patients who underwent total hip arthroplasty with the smallest type 1 stem or with type 3 C stem at a single institution from July 2014 to March 2022. A Type 3 C stem was used when the smallest type 1 stem failed to achieve metaphyseal fixation. One hundred twenty-six patients were categorized into two main groups. Canal-flare index, canal-calcar ratio, modified morphological cortical index, and two novel indices (lesser trochanter-to-distal ratio-α and -ß [LDR-α and -ß]) were assessed on preoperative pelvic radiographs.

RESULTS:

Multivariate and ROC analysis demonstrated that high LDR-ß (Exp[B] 485.51, CI 36.67-6427.97, p < 0.001) was associated with a more mismatched tendency group and had clinically acceptable discriminatory power (AUC 0.765, CI 0.675-0.855, p < 0.001) between the two cohorts.

CONCLUSION:

Correct assessment of preoperative femoral morphology would be fundamental in the selection of a suitable stem. The ratio based on 3 cm below the lesser trochanter of the femur seemed crucial. We recommend evaluating the newly described radiological index preoperatively in M-D mismatched Dorr A femur for planning precisely and selecting a proper stem.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article