Finite element investigation of the influence of a new transpedicular vertebral implant positioning on biomechanical responses of the spine segment.
Hambli, Ridha; De Leacy, Reade; Cornelis, François; Vienney, Cécile.
Afiliación
  • Hambli R; Univ. Orléans, Univ. Tours, INSA CVL, LaMé, 45000 Orléans, France. Electronic address: ridha.hambli@univ-orleans.fr.
  • De Leacy R; Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Cornelis F; Memorial Sloan Kettering Cancer Center & Weill Cornell Medical College, Radiology Department, 1275 York Avenue, New York, NY 10065, USA.
  • Vienney C; Hyprevention, Research and Development, Pessac, France.
Med Eng Phys ; 124: 104100, 2024 02.
Article en En | MEDLINE | ID: mdl-38418016
ABSTRACT
The optimal positioning of an implant into a living organ such as femurs and vertebra is still an open problem. In particular, vertebral implant position has a significant impact on the results on spine behaviour after treatment in terms of stiffness, range of motion (ROM), wear, loosening and failure. In the current work, a 3D finite element analysis was conducted to investigate the positioning parameters of a novel transpedicular implant (V-STRUT©, Hyprevention, France) in terms of placement of the implant in the treated vertebra. The implant was designed in order to strength osteoporotic vertebral body and the related spine segment under compressive load. The effects of the axial and sagittal positions of the implant in the treated vertebra was investigated in terms of stress and stiffness variations. A 3D finite element model of an osteoporotic spine segment was built based on a Computed Tomography (CT) scan of an osteoporotic female (69 yo). The model is composed of T12, L1 and L2 vertebrae and corresponding intervertebral discs and ligaments. The bone tissue was modeled as a heterogeneous material with properties assigned based on the grey scale levels. The intervertebral discs were modeled using two regions describing the annulus and the nucleus and linear beam elements with specific stiffness each were used representing each ligament. The simulations indicated that the sagittal position (distance d) plays a role on the stress distribution. The closer the implant to the interior wall the lower the stress applied to the spine segment. Nevertheless, the axial plane position (distance h) have limited effects on the stress applied to the bone with a higher stress applied to the device (subjected to a higher bending load). These results can have direct clinical implications when dealing with the optimal placement of the implant. It is also possible to select a particular position in order to assign a given (target) stiffness for a patient.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Columna Vertebral / Disco Intervertebral Límite: Female / Humans Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Columna Vertebral / Disco Intervertebral Límite: Female / Humans Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article