Your browser doesn't support javascript.
loading
Transcatheter aortic valve implantation in patients with significant septal hypertrophy.
Beyer, Martin; Demal, Till Joscha; Bhadra, Oliver D; Linder, Matthias; Ludwig, Sebastian; Grundmann, David; Voigtlaender-Buschmann, Lisa; Waldschmidt, Lara; Schirmer, Johannes; Schofer, Niklas; Pecha, Simon; Blankenberg, Stefan; Reichenspurner, Hermann; Conradi, Lenard; Seiffert, Moritz; Schaefer, Andreas.
Afiliación
  • Beyer M; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. ma.beyer@uke.de.
  • Demal TJ; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Bhadra OD; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Linder M; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Ludwig S; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Grundmann D; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Voigtlaender-Buschmann L; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Waldschmidt L; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Schirmer J; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Schofer N; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Pecha S; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Blankenberg S; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Reichenspurner H; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Conradi L; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
  • Seiffert M; Department of Cardiology, University Heart & Vascular Center Hamburg, 20246, Hamburg, Germany.
  • Schaefer A; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Clin Res Cardiol ; 2024 Mar 11.
Article en En | MEDLINE | ID: mdl-38466346
ABSTRACT

BACKGROUND:

Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients.

AIMS:

This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI.

METHODS:

Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses.

RESULTS:

Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758).

CONCLUSION:

Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Clin Res Cardiol Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania