Your browser doesn't support javascript.
loading
Analysis of laboratory data transmission between two healthcare institutions using a widely used point-to-point health information exchange platform: a case report.
Luu, Hung S; Campbell, Walter S; Cholan, Raja A; Edgerton, Mary E; Englund, Andrea; Keller, Alana; Korte, Elizabeth D; Mitchell, Sandra H; Watkins, Greg T; Westervelt, Lindsay; Wyman, Daniel; Powell, Stephen.
Afiliación
  • Luu HS; Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States.
  • Campbell WS; Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE 68198, United States.
  • Cholan RA; Deloitte Consulting LLP, Washington, DC 20004, United States.
  • Edgerton ME; Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE 68198, United States.
  • Englund A; Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE 68198, United States.
  • Keller A; Synensys, LLC, Peachtree, GA 30269, United States.
  • Korte ED; Deloitte Consulting LLP, Washington, DC 20004, United States.
  • Mitchell SH; JP Systems, Inc., Clifton, VA 20124, United States.
  • Watkins GT; Deloitte Consulting LLP, Washington, DC 20004, United States.
  • Westervelt L; JP Systems, Inc., Clifton, VA 20124, United States.
  • Wyman D; Synensys, LLC, Peachtree, GA 30269, United States.
  • Powell S; Synensys, LLC, Peachtree, GA 30269, United States.
JAMIA Open ; 7(2): ooae032, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38660616
ABSTRACT

Objective:

The objective was to identify information loss that could affect clinical care in laboratory data transmission between 2 health care institutions via a Health Information Exchange platform. Materials and

Methods:

Data transmission results of 9 laboratory tests, including LOINC codes, were compared in the following between sending and receiving electronic health record (EHR) systems, the individual Health Level Seven International (HL7) Version 2 messages across the instrument, laboratory information system, and sending EHR.

Results:

Loss of information for similar tests indicated the following potential patient safety issues (1) consistently missing specimen source; (2) lack of reporting of analytical technique or instrument platform; (3) inconsistent units and reference ranges; (4) discordant LOINC code use; and (5) increased complexity with multiple HL7 versions. Discussion and

Conclusions:

Using an HIE with standard messaging, SHIELD (Systemic Harmonization and Interoperability Enhancement for Laboratory Data) recommendations, and enhanced EHR functionality to support necessary data elements would yield consistent test identification and result value transmission.