Improvement of the Upper Detection Limit of Ionophore-Based H+-Selective Electrodes: Explanation and Elimination of Apparently Super-Nernstian Responses.
Honig, Madeline L; Haba, Ariki; O'Leary, Katie M F; Robinson, Emily E A; Madungwe, Kuzivakwashe V; Lin, Ye; McGuire, Chad; Bühlmann, Philippe.
Afiliación
  • Honig ML; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
  • Haba A; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
  • O'Leary KMF; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
  • Robinson EEA; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
  • Madungwe KV; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
  • Lin Y; Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States.
  • McGuire C; Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States.
  • Bühlmann P; Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States.
Anal Chem ; 96(24): 9901-9908, 2024 Jun 18.
Article en En | MEDLINE | ID: mdl-38850234
ABSTRACT
The response range of an ion-selective electrode (ISE) has been described by counterion interference at the lower and Donnan failure at the upper detection limit. This approach fails when the potentiometric response at the upper detection limit exhibits an apparently super-Nernstian response, as has been reported repeatedly for H+-selective electrodes. While also observed when samples contain other anions, super-Nernstian responses at low pH are a problem in particular for samples that contain phthalate, a common component of commercial pH calibration solutions. This work shows that coextraction of H+ and a sample anion into the sensing membrane alone does not explain these super-Nernstian responses, even when membrane-internal diffusion potentials are taken into account. Instead, these super-Nernstian responses are explained by the formation of complexes between that anion and at least two protonated ionophore molecules. As demonstrated by experiments and explained with quantitative phase boundary models, the apparently super-Nernstian responses at low pH can be eliminated by restricting the molecular ratio of ionophore and ionic sites. Notably, this conclusion results in recommendations for the optimization of sensing membranes that, in some instances, will conflict with previously reported recommendations from the ionic site theory for the optimization of the lower detection limit. This mechanistic insight is key to maximizing the response range of these ionophore-based ISEs.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Anal Chem Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos