Predicting the impact of femtosecond-assisted arcuate keratotomy combined with tri-planar clear corneal incisions on astigmatism in implantable collamer lens surgery: one-year follow-up.
Zhou, Jihong; Li, Shaowei; He, Guoli; Wang, Wenjuan.
Afiliación
  • Zhou J; Beijing Aier Intech Eye Hospital, Panjiayuan Plaza, #12 Panjiayuan Nanli, Chaoyang District, Beijing, China. aiqihong0916@163.com.
  • Li S; Beijing Ophthalmology and Science Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. aiqihong0916@163.com.
  • He G; Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, No. 1 Dongjiaomin Xiang, Dongcheng District, Beijing, 100730, China. aiqihong0916@163.com.
  • Wang W; Beijing Aier Intech Eye Hospital, Panjiayuan Plaza, #12 Panjiayuan Nanli, Chaoyang District, Beijing, China.
Article en En | MEDLINE | ID: mdl-38896281
ABSTRACT

PURPOSE:

To investigate the factors associated with and impact on the femtosecond-assisted (FS-assisted) limbal relaxing incision (LRI) combined with the steep-meridian tri-planar clear corneal incision (TCCI) to reduce astigmatism in patients undergoing Implantable Collamer Lens (ICL) surgery.

METHODS:

Retrospective case series. The study reviewed patients with ICL surgery combined with FS-assisted LRIs paired with steep-meridian TCCIs. Correlation analysis examined the relationship between independent variables, including preoperative characteristics (intraocular pressure, corneal thickness, axial length, et al.), TCCI, and LRI surgical parameters. The predictors of surgically induced astigmatism (SIA) were determined using individual-level analysis and accounting for inter-eye correlation with the generalized estimating equation (GEE).

RESULTS:

The study enrolled 69 patients, with 114 eyes (55 right and 59 left). The mean spherical equivalent (SEQ) was - 10.29 ± 2.99D and - 9.99 ± 2.72D for the right and left eye, respectively, while the mean preoperative corneal astigmatism was - 1.54 ± 0.47D and - 1.54 ± 0.46D for the right and left eyes, respectively. After 12 months of follow-up, univariate analysis revealed significant correlations between SIA and intraocular pressure (IOP), astigmatism type, TCCI position (degree), peripheral corneal thickness (PCT), LRI arc incision diameter, post depth (%), and angle, respectively (P = 0.046, 0.016, 0.039, 0.040, 0.009, 0.000, 0.000). Multivariate analysis using GEE demonstrated that axial length (AL), astigmatism type, LRI arc diameter, and angle were independent predictors of SIA (P = 0.000, 0.005, 0.029, 0.000).

CONCLUSIONS:

The type of astigmatism and axial length were independent factors that affected SIA when modifying the LRI arc diameter and angle through FS-assisted steep-meridian TCCI paired with LRI in ICL surgery.