Au Nanoshell-Based Lateral Flow Immunoassay for Colorimetric and Photothermal Dual-Mode Detection of Interleukin-6.
Wen, Congying; Dou, Yue; Liu, Yao; Jiang, Xuan; Tu, Xiaomei; Zhang, Ruiqiao.
Afiliación
  • Wen C; College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
  • Dou Y; College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
  • Liu Y; College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
  • Jiang X; College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
  • Tu X; College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
  • Zhang R; Qingdao Academy of Agricultural Sciences, Qingdao 266100, China.
Molecules ; 29(15)2024 Aug 03.
Article en En | MEDLINE | ID: mdl-39125086
ABSTRACT
Interleukin-6 (IL-6) detection and monitoring are of great significance for evaluating the progression of many diseases and their therapeutic efficacy. Lateral flow immunoassay (LFIA) is one of the most promising point-of-care testing (POCT) methods, yet suffers from low sensitivity and poor quantitative ability, which greatly limits its application in IL-6 detection. Hence, in this work, we integrated Aushell nanoparticles (NPs) as new LFIA reporters and achieved the colorimetric and photothermal dual-mode detection of IL-6. Aushell NPs were conveniently prepared using a galvanic exchange process. By controlling the shell thickness, their localized surface plasmon resonance (LSPR) peak was easily tuned to near-infrared (NIR) range, which matched well with the NIR irradiation light. Thus, the Aushell NPs were endowed with good photothermal effect. Aushell NPs were then modified with IL-6 detection antibody to construct Aushell probes. In the LFIA detection, the Aushell probes were combined with IL-6, which were further captured by the capture IL-6 antibody on the test line of the strip, forming a colored band. By observation with naked eyes, the colorimetric qualitative detection of IL-6 was achieved with limit of 5 ng/mL. By measuring the temperature rise of the test line with a portable infrared thermal camera, the photothermal quantitative detection of IL-6 was performed from 1~1000 ng/mL. The photothermal detection limit reached 0.3 ng/mL, which was reduced by nearly 20 times compared with naked-eye detection. Therefore, this Aushell-based LFIA efficiently improved the sensitivity and quantitative ability of commercial colloidal gold LFIA. Furthermore, this method showed good specificity, and kept the advantages of convenience, speed, cost-effectiveness, and portability. Therefore, this Aushell-based LFIA exhibits practical application potential in IL-6 POCT detection.