RESUMEN
BACKGROUND: The effects of elexacaftor/tezacaftor/ivacaftor (ETI) on respiratory outcomes for people with cystic fibrosis (CF) were demonstrated by several clinical trials, mainly based on simple spirometry. However, gains in lung function may vary greatly between patients, and predictors of FEV1 change after treatment have yet to be defined. RESEARCH QUESTION: Which ventilatory parameters are involved in the heterogeneity of FEV1 change after 12-month ETI treatment in people with CF and advanced lung disease? STUDY DESIGN AND METHODS: This was a multicenter, observational, prospective cohort study at two major CF centers in Italy. We enrolled 47 adults with CF and advanced lung disease (FEV1 < 40% or actively listed for lung transplant) who started ETI treatment between December 2019 and December 2021. At treatment initiation and after 12 months, patients underwent body plethysmography. Values were compared at the two time points. To assess the relationship between baseline plethysmography measurements and treatment-induced changes in FEV1, we used the Spearman rank correlation coefficient (rs) and median quantile regressions. RESULTS: After 12 months of ETI treatment, there was a significant increase in FEV1 % predicted from a median value of 36.0 (25th-75th percentile, 33-39) to 52 (25th-75th percentile, 43-61) (P < .001). Inspiratory capacity/total lung capacity (TLC) ratio also increased from 32.0 (25th-75th percentile, 28.6-36.9) to 36.3 (25th-75th percentile, 33.4-41.3) (P < .001). Specific airway resistance decreased from 263 (25th-75th percentile, 182-405) to 207 (25th-75th percentile, 120-258) (P < .001). Functional residual capacity/TLC ratio decreased from 68.2 (25th-75th percentile, 63.3-71.9) to 63.9 (25th-75th percentile, 58.8-67.1) (P < .001), and residual volume/TLC ratio decreased from 53.1 (25th-75th percentile, 48.3-59.4) to 45.6 (25th-75th percentile, 39.4-49.8) (P < .001). Changes in FEV1 % predicted negatively correlated with baseline functional residual capacity/TLC ratio (rs = -0.38, P = .009) and residual volume/TLC ratio (rs = -0.42, P = .004). After adjustment for age at treatment initiation and cystic fibrosis transmembrane conductance regulator genotype, we estimated that for each 10-unit increase in baseline residual volume/TLC ratio, the expected median change in FEV1 decreased by 2.3 (95% CI, -5.8 to -0.8). INTERPRETATION: ETI was associated with improvements in both static and dynamic volumes in people with CF and advanced lung disease. Heterogeneity in FEV1 % predicted change after 12 months of treatment may be predicted by the severity of hyperinflation at baseline.
Asunto(s)
Aminofenoles , Benzodioxoles , Fibrosis Quística , Combinación de Medicamentos , Indoles , Piridinas , Pirrolidinas , Quinolonas , Humanos , Fibrosis Quística/tratamiento farmacológico , Fibrosis Quística/fisiopatología , Masculino , Femenino , Adulto , Estudios Prospectivos , Aminofenoles/uso terapéutico , Benzodioxoles/uso terapéutico , Quinolonas/uso terapéutico , Piridinas/uso terapéutico , Indoles/uso terapéutico , Pirrolidinas/uso terapéutico , Pirazoles/uso terapéutico , Volumen Espiratorio Forzado , Pletismografía , Italia , Pulmón/fisiopatología , QuinolinasRESUMEN
BACKGROUND: Percutaneous Microwave Ablation (MWA) of lung malignancies is a procedure with many technical challenges, among them the risk of residual disease. Recently, dedicated software able to predict the volume of the ablated area was introduced. Cone-beam computed tomography (CBCT) is the imaging guidance of choice for pulmonary ablation in our institution. The volumetric prediction software (VPS) has been installed and used in combination with CBCT to check the correct position of the device. Our study aimed to compare the results of MWA of pulmonary tumours performed using CBCT with and without VPS. METHODS: We retrospectively reviewed 1-month follow-up enhanced contrast-enhanced computed tomography (CECT) scans of 10 patients who underwent ablation with the assistance of VPS (group 1) and of 10 patients who were treated without the assistance of VPS (group 2). All patients were treated for curative purposes, the maximum axial diameter of lesions ranged between 5 and 22 mm in group 1 and between 5 and 25 mm in group 2. We compared the presence of residual disease between the two groups. RESULTS: In group 1 residual disease was seen in only 1 patient (10%) in which VPS had ensured complete coverage of the tumour. In group 2 residual disease was found in 3 patients (30%). CONCLUSIONS: Using this software during MWA of lung malignancies could improve the efficacy of the treatment compared to the conventional only CBCT guidance.
Asunto(s)
Ablación por Catéter , Neoplasias Pulmonares , Humanos , Estudios Retrospectivos , Microondas/uso terapéutico , Ablación por Catéter/métodos , Pulmón/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugíaRESUMEN
Imaging-guided percutaneous ablative treatments, such as radiofrequency ablation (RFA), cryoablation and microwave ablation (MWA), have been developed for the treatment of unresectable primary and secondary lung tumors in patients with advanced-stage disease or comorbidities contraindicating surgery. Among these therapies, MWA has recently shown promising results in the treatment of pulmonary neoplasms. The potential advantages of MWA over RFA include faster ablation times, higher intra-tumoral temperatures, larger ablation zones and lower susceptibility to the heat sink effect, resulting in greater efficacy in proximity to vascular structures. Despite encouraging results supporting its efficacy, there is a relative paucity of data in the literature regarding the role of computer tomography (CT) to monitor MWA-treated lesions, and the CT appearance of their morphologic evolution and complications. For both interventional and non-interventional radiologists, it is crucial to be familiar with the CT features of such treated lesions in order to detect incomplete therapy or recurrent disease at early stage, as well as to recognize initial signs of complications. The aim of this pictorial essay is to describe the typical CT features during follow-up of lung lesions treated with percutaneous MWA and how to interpret and differentiate them from other radiological findings, such as recurrence and complications, that are commonly encountered in this setting.
Asunto(s)
Neoplasias Pulmonares , Ablación por Radiofrecuencia , Computadores , Humanos , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Ablación por Radiofrecuencia/métodos , Tomografía Computarizada por Rayos XRESUMEN
PURPOSE: Radiologic criteria for the diagnosis of primary graft dysfunction (PGD) after lung transplantation are nonspecific and can lead to misinterpretation. The primary aim of our study was to assess the interobserver agreement in the evaluation of chest X-rays (CXRs) for PGD diagnosis and to establish whether a specific training could have an impact on concordance rates. Secondary aim was to analyze causes of interobserver discordances. MATERIAL AND METHODS: We retrospectively enrolled 164 patients who received bilateral lung transplantation at our institution, between February 2013 and December 2019. Three radiologists independently reviewed postoperative CXRs and classified them as suggestive or not for PGD. Two of the Raters performed a specific training before the beginning of the study. A senior thoracic radiologist subsequently analyzed all discordant cases among the Raters with the best agreement. Statistical analysis to calculate interobserver variability was percent agreement, Cohen's kappa and intraclass correlation coefficient. RESULTS: A total of 473 CXRs were evaluated. A very high concordance among the two trained Raters, 1 and 2, was found (K = 0.90, ICC = 0.90), while a poorer agreement was found in the other two pairings (Raters 1 and 3: K = 0.34, ICC = 0.40; Raters 2 and 3: K = 0.35, ICC = 0.40). The main cause of disagreement (52.4% of discordant cases) between Raters 1 and 2 was the overestimation of peribronchial thickening in the absence of unequivocal bilateral lung opacities or the incorrect assessment of unilateral alterations. CONCLUSION: To properly identify PGD, it is recommended for radiologists to receive an adequate specific training.
Asunto(s)
Competencia Clínica/estadística & datos numéricos , Trasplante de Pulmón , Disfunción Primaria del Injerto/diagnóstico por imagen , Radiografía/métodos , Radiólogos/educación , Adolescente , Adulto , Anciano , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto JovenRESUMEN
Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA), occurring in less than 1% of all AAAs. Paradoxical embolism can rarely be associated with ACF, pulmonary embolism may originate from dislodgment of thrombotic material from the AAA in the inferior vena cava (IVC) through the ACF. We report a case of a patient admitted to the emergency department with abdominal pain and shortness of breath who immediately underwent thoraco-abdominal CT. Imaging allowed a prompt pre-operative diagnosis of an ACF between an AAA and the IVC, also identifying CT signs of right heart overload and the presence of a paradoxical pulmonary embolism.
RESUMEN
PURPOSE: Aim of the study is to evaluate the incidence of DVT in COVID-19 patients and its correlation with the severity of the disease and with clinical and laboratory findings. METHODS: 234 symptomatic patients with COVID-19, diagnosed according to the World Health Organization guidelines, were included in the study. The severity of the disease was classified as moderate, severe and critical. Doppler ultrasound (DUS) was performed in all patients. DUS findings, clinical, laboratory's and therapeutic variables were investigated by contingency tables, Pearson chi square test and by Student t test and Fisher's exact test. ROC curve analysis was applied to study significant continuous variables. RESULTS: Overall incidence of DVT was 10.7% (25/234): 1.6% (1/60) among moderate cases, 13.8% (24/174) in severely and critically ill patients. Prolonged bedrest and intensive care unit admission were significantly associated with the presence of DVT (19.7%). Fraction of inspired oxygen, P/F ratio, respiratory rate, heparin administration, D-dimer, IL-6, ferritin and CRP showed correlation with DVT. CONCLUSION: DUS may be considered a useful and valid tool for early identification of DVT. In less severely affected patients, DUS as screening of DVT might be unnecessary. High rate of DVT found in severe patients and its correlation with respiratory parameters and some significant laboratory findings suggests that these can be used as a screening tool for patients who should be getting DUS.
Asunto(s)
COVID-19/complicaciones , Ultrasonografía Doppler Dúplex/métodos , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen , Adulto , Anciano , Proteína C-Reactiva/metabolismo , Enfermedad Crítica , Diagnóstico Precoz , Ferritinas/sangre , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Heparina/administración & dosificación , Heparina/sangre , Humanos , Incidencia , Unidades de Cuidados Intensivos , Interleucina-6/sangre , Masculino , Persona de Mediana Edad , Oxígeno/metabolismo , Frecuencia Respiratoria , Medición de Riesgo , SARS-CoV-2 , Índice de Severidad de la Enfermedad , Trombosis de la Vena/sangreRESUMEN
To describe radiographic key patterns on Chest X-ray (CXR) in patients with SARS-CoV-2 infection, assessing the prevalence of radiographic signs of interstitial pneumonia. To evaluate pattern variation between a baseline and a follow-up CXR. 1117 patients tested positive for SARS-CoV-2 infection were retrospectively enrolled from four centers in Lombardy region. All patients underwent a CXR at presentation. Follow-up CXR was performed when clinically indicated. Two radiologists in each center reviewed images and classified them as suggestive or not for interstitial pneumonia, recording the presence of ground-glass opacity (GGO), reticular pattern or consolidation and their distribution. Pearson's χ2 test for categorical variables and McNemar test (χ2 for paired data) were performed. Patients mean age 63.3 years, 767 were males (65.5%). The main result is the large proportion of positive CXR in COVID-19 patients. Baseline CXR was positive in 940 patients (80.3%), with significant differences in age and sex distribution between patients with positive and negative CXR. 382 patients underwent a follow-up CXR. The most frequent pattern on baseline CXR was the GGO (66.1%), on follow-up was consolidation (53.4%). The most common distributions were peripheral and middle-lower lung zone. We described key-patterns and their distribution on CXR in a large cohort of COVID-19 patients: GGO was the most frequent finding on baseline CXR, while we found an increase in the proportion of lung consolidation on follow-up CXR. CXR proved to be a reliable tool in our cohort obtaining positive results in 80.3% of the baseline cases.
Asunto(s)
COVID-19/diagnóstico por imagen , Radiografía Torácica/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/epidemiología , Estudios de Cohortes , Femenino , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Radiografía Torácica/estadística & datos numéricos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodosRESUMEN
Preparedness for the ongoing coronavirus disease 2019 (COVID-19) and its spread in Italy called for setting up of adequately equipped and dedicated health facilities to manage sick patients while protecting healthcare workers, uninfected patients, and the community. In our country, in a short time span, the demand for critical care beds exceeded supply. A new sequestered hospital completely dedicated to intensive care (IC) for isolated COVID-19 patients needed to be designed, constructed, and deployed. Along with this new initiative, the new concept of "Pandemic Radiology Unit" was implemented as a practical solution to the emerging crisis, born out of a critical and urgent acute need. The present article describes logistics, planning, and practical design issues for such a pandemic radiology and critical care unit (e.g., space, infection control, safety of healthcare workers, etc.) adopted in the IC Hospital Unit for the care and management of COVID-19 patients.
Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/prevención & control , Infección Hospitalaria/prevención & control , Arquitectura y Construcción de Hospitales , Hospitales de Aislamiento/organización & administración , Pandemias/prevención & control , Neumonía Viral/prevención & control , Servicio de Radiología en Hospital/organización & administración , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/terapia , Humanos , Unidades de Cuidados Intensivos/organización & administración , Italia/epidemiología , Equipo de Protección Personal , Admisión y Programación de Personal/organización & administración , Neumonía Viral/epidemiología , Neumonía Viral/terapia , Radiografía , SARS-CoV-2 , Tomografía Computarizada por Rayos X/instrumentación , UltrasonografíaAsunto(s)
Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Vena Porta/diagnóstico por imagen , Trombosis de la Vena/etiología , Enfermedad Aguda , Anciano , Anticoagulantes/uso terapéutico , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/terapia , Enoxaparina/uso terapéutico , Humanos , Masculino , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/terapia , SARS-CoV-2 , Tomografía Computarizada por Rayos X , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/tratamiento farmacológico , Trombosis de la Vena/virologíaAsunto(s)
Dolor Abdominal/etiología , Lesión Renal Aguda/complicaciones , Ascitis/etiología , Rotura/complicaciones , Dolor Abdominal/fisiopatología , Lesión Renal Aguda/fisiopatología , Anciano , Ascitis/fisiopatología , Creatinina/análisis , Ecocardiografía/métodos , Femenino , Humanos , Paracentesis/métodos , Rotura/diagnóstico por imagen , España , Ultrasonografía/métodos , Urea/análisis , Vejiga Urinaria/anomalías , Vejiga Urinaria/lesiones , Vejiga Urinaria/fisiopatologíaRESUMEN
The case of a patient admitted to the hospital for symptoms characterized by chest pain, productive cough, fever, dyspnea resistant to antibiotic therapy is discussed. Previous plain chest X-ray performed elsewhere was suggestive of inflammotory lung consolidation. An admission chest X-ray revealed a left lower lobe density. On chest CT-angiography a lobulated mass in the posterior basal segment of the left lower lobe was visualized: the diagnosis of intralobar pulmonary sequestration (ILPS) was hypothesized.
Asunto(s)
Secuestro Broncopulmonar/diagnóstico , Anciano , Humanos , Masculino , Tomografía Computarizada por Rayos XRESUMEN
The case of a premature infant with hyaline membrane disease (respiratory distress syndrome) is discussed. On chest X-ray reduced volume and transparency of both lungs with ground-glass appearance and presence of bilateral air bronchogram was visualized. These findings are analyzed with respect to possible diagnostic alternatives.
Asunto(s)
Enfermedad de la Membrana Hialina/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Recién Nacido , Recien Nacido Prematuro , RadiografíaRESUMEN
The case of a patient with intermittent dysphagia and suspected GERD is discussed. Pharyngoesophageal scintigraphy was performed. Reflux test was negative. To better define the lesion and establish the diagnosis the study was completed with an X-ray of the upper digestive tract. The finding of a barium collection and a tear in the posterior wall of the pharyngoesophageal tract was suggestive of the diagnosis of Zenker's pseudodiverticulum.