Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38409476

RESUMEN

In-hospital mortality associated with cardiogenic shock (CS) remains high despite the use of percutaneous assist devices. We sought to determine whether support with VA-ECMO or Impella in patients with CS alters specific components of the plasma proteome. Plasma samples were collected before device implantation and 72 h after initiation of support in 11 CS patients receiving ECMO or Impella. SOMAscan was used to detect 1305 circulating proteins. Sixty-seven proteins were changed after ECMO (18 upregulated and 49 downregulated, p < 0.05), 38 after Impella (10 upregulated and 28 downregulated, p < 0.05), and only eight proteins were commonly affected. Despite minimal protein overlap, both devices were associated with markers of reduced inflammation and increased apoptosis of inflammatory cells. In summary, ECMO and Impella are associated with reduced expression of inflammatory markers and increased markers of inflammatory cell death. These circulating proteins may serve as novel targets of therapy or biomarkers to tailor AMCS use.

2.
Clin Cardiol ; 46(1): 76-83, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36273422

RESUMEN

BACKGROUND: Adverse cardiac events are common following transcatheter aortic valve replacement (TAVR). Our aim was to investigate the low left ventricular stroke volume index (LVSVI) 30 days after TAVR as an early echocardiographic marker of survival. HYPOTHESIS: Steady-state (30-day) LVSVI after TAVR is associated with 1-year mortality. METHODS: A single-center retrospective analysis of all patients undergoing TAVR from 2017 to 2019. Baseline and 30-day post-TAVR echocardiographic LVSVI were calculated. Patients were stratified by pre-TAVR transaortic gradient, surgical risk, and change in transvalvular flow following TAVR. RESULTS: This analysis focuses on 238 patients treated with TAVR. The 1-year mortality rate was 9% and 124 (52%) patients had normal flow post-TAVR. Of those with pre-TAVR low flow, 67% of patients did not normalize LVSVI at 30 days. The 30-day normal flow was associated with lower 1-year mortality when compared to low flow (4% vs. 14%, p = .007). This association remained significant after adjusting for known predictors of risk (adjusted odds ratio [OR] of 3.45, 95% confidence interval: 1.02-11.63 [per 1 ml/m2 decrease], p = .046). Normalized transvalvular flow following TAVR was associated with reduced mortality (8%) when compared to those with persistent (15%) or new-onset low flow (12%) (p = .01). CONCLUSIONS: LVSVI at 30 days following TAVR is an early echocardiographic predictor of 1-year mortality and identifies patients with worse intermediate outcomes. More work is needed to understand if this short-term imaging marker might represent a novel therapeutic target.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda , Factores de Riesgo
3.
J Cardiovasc Transl Res ; 15(2): 207-216, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33782857

RESUMEN

New mechanistic insight into how the kidney responds to cardiac injury during acute myocardial infarction (AMI) is required. We hypothesized that AMI promotes inflammation and matrix metalloproteinase-9 (MMP9) activity in the kidney and studied the effect of initiating an Impella CP or veno-arterial extracorporeal membrane oxygenation (VA-ECMO) before coronary reperfusion during AMI. Adult male swine were subjected to coronary occlusion and either reperfusion (ischemia-reperfusion; IR) or support with either Impella or VA-ECMO before reperfusion. IR and ECMO increased while Impella reduced levels of MMP-9 in the myocardial infarct zone, circulation, and renal cortex. Compared to IR, Impella reduced myocardial infarct size and urinary KIM-1 levels, but VA-ECMO did not. IR and VA-ECMO increased pro-fibrogenic signaling via transforming growth factor-beta and endoglin in the renal cortex, but Impella did not. These findings identify that AMI increases inflammatory activity in the kidney, which may be attenuated by Impella support.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Infarto del Miocardio , Animales , Masculino , Metaloproteinasa 9 de la Matriz , Choque Cardiogénico , Porcinos
4.
J Cardiovasc Transl Res ; 13(2): 151-157, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31773461

RESUMEN

Congestion is a major determinant of clinical outcomes in heart failure (HF). We compared the acute hemodynamic effects of occlusion of the superior (SVC) versus the inferior vena cava (IVC) and tested a novel SVC occlusion system in swine models of HF. IVC occlusion acutely reduced left ventricular (LV) systolic and diastolic pressures, LV volumes, cardiac output (CO), and mean arterial pressure (MAP). SVC occlusion reduced LV diastolic pressure and volumes without affecting CO or MAP. The preCARDIA system is a balloon occlusion catheter and pump console which enables controlled delivery and removal of fluid into the occlusion balloon. At 6, 12, and 18 h, SVC therapy with the system provided a sustained reduction in cardiac filling pressures with stable CO and MAP. Intermittent SVC occlusion is a novel approach to reduce biventricular filling pressures in HF. The VENUS-HF trial will test the safety and feasibility of SVC therapy in HF.


Asunto(s)
Oclusión con Balón , Insuficiencia Cardíaca/terapia , Vena Cava Superior/fisiopatología , Función Ventricular Izquierda , Presión Ventricular , Animales , Presión Arterial , Gasto Cardíaco , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Masculino , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Prueba de Estudio Conceptual , Sus scrofa , Factores de Tiempo , Presión Venosa
5.
J Am Heart Assoc ; 8(22): e013586, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31698989

RESUMEN

Background Unloading the left ventricle and delaying reperfusion reduces infarct size in preclinical models of acute myocardial infarction. We hypothesized that a potential explanation for this effect is that left ventricular (LV) unloading before reperfusion increases collateral blood flow to ischemic myocardium. Methods and Results Acute myocardial infarction was induced by balloon occlusion of the left anterior descending artery for 120 minutes in adult swine, followed by reperfusion for 180 minutes. After 90 minutes of occlusion, animals were assigned to 30 minutes of continued occlusion (n=6) or to 30 minutes of support with either an Impella CP (n=4) or venoarterial extracorporeal membrane oxygenation (n=5) with persistent occlusion. The primary end point was measures of microcirculatory blood flow including the collateral flow index (CFI) during left anterior descending artery occlusion as (Pw-RA)/(Pa-RA), where Pa, Pw, and RA are aortic, coronary wedge, and right atrial pressure, respectively. Infarct size was quantified using triphenyltetrazolium chloride. Compared with continued occlusion, Impella, not venoarterial extracorporeal membrane oxygenation, reduced infarct size relative to the area at risk. Before reperfusion, Impella reduced LV stroke work by 25% and increased the CFI by 75%, but venoarterial extracorporeal membrane oxygenation did not. Among all groups, the change in CFI between 90 and 120 minutes correlated inversely with the change in LV stroke work (r2=0.44, P=0.01) and infarct size (r2=0.41, P=0.02). Conclusions We report for the first time that 30 minutes of LV unloading during coronary occlusion increases the CFI, which correlates inversely with LV stroke work and infarct size. Venoarterial extracorporeal membrane oxygenation failed to increase the CFI and did not reduce infarct size.


Asunto(s)
Circulación Asistida/métodos , Circulación Colateral , Circulación Coronaria , Oxigenación por Membrana Extracorpórea/métodos , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/patología , Reperfusión Miocárdica , Miocardio/patología , Animales , Cateterismo Cardíaco , Cateterismo de Swan-Ganz , Vasos Coronarios , Corazón Auxiliar , Masculino , Microcirculación , Daño por Reperfusión Miocárdica/terapia , Presión , Índice de Severidad de la Enfermedad , Sus scrofa , Función Ventricular Izquierda
6.
Catheter Cardiovasc Interv ; 93(7): 1205-1210, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-31112633

RESUMEN

BACKGROUND: Acutely decompensated heart failure remains a major clinical problem. Volume overload promotes cardiac and renal dysfunction and is associated with increased morbidity and mortality in heart failure. We hypothesized that transient occlusion of the superior vena cava (SVC) will reduce cardiac filling pressures without reducing cardiac output or systemic blood pressure. The objective of this proof of concept study was to provide initial evidence of safety and feasibility of transient SVC occlusion in patients with acutely decompensated heart failure and reduced ejection fraction. METHODS AND RESULTS: In eight patients with systolic heart failure, SVC occlusion was performed using a commercially available occlusion balloon. Five minutes of SVC occlusion reduced biventricular filling pressures without decreasing systemic blood pressure or total cardiac output. In three of the eight patients, a second 10-minutes occlusion had similar hemodynamic effects. SVC occlusion was well-tolerated without development of new symptoms, new neurologic deficits, or any adverse events including stroke, heart attack, or reported SVC injury or thrombosis at 7 days of follow up. CONCLUSION: We report the first clinical experience with transient SVC occlusion as a potentially new therapeutic approach to rapidly reduce cardiac filling pressures in heart failure. No prohibitive safety signal was identified and further testing to establish the clinical utility of transient SVC occlusion for acute decompensated heart failure is justified.


Asunto(s)
Oclusión con Balón , Insuficiencia Cardíaca/terapia , Vena Cava Superior/fisiopatología , Función Ventricular Izquierda , Función Ventricular Derecha , Presión Ventricular , Anciano , Oclusión con Balón/efectos adversos , Oclusión con Balón/instrumentación , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Prueba de Estudio Conceptual , Recuperación de la Función , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Dispositivos de Acceso Vascular , Vena Cava Superior/diagnóstico por imagen
7.
J Cardiovasc Transl Res ; 12(2): 87-94, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-31016553

RESUMEN

Acute myocardial infarction (AMI) remains a leading cause of morbidity and mortality. Pioneering preclinical work reported by Peter Maroko and Eugene Braunwald in 1971 identified oxygen supply and demand are primary determinants of myocardial infarct size in the setting of a heart attack. Since the 1950s, advances in mechanical engineering led to the development of short-term circulatory support devices that range from pulsatile to continuous flow pumps. The primary objective of these pumps is to reduce native heart work, enhance coronary blood flow, and sustain systemic perfusion. Whether these pumps could reduce myocardial infarct size in the setting of AMI became an intense focus for preclinical investigation with variable animal models, experimental algorithms, and pump platforms being tested. In this review, we discuss the design of these preclinical studies and the evolution of mechanical support platforms and attempt to translate these experimental methods into clinical trials.


Asunto(s)
Insuficiencia Cardíaca/prevención & control , Corazón Auxiliar , Infarto del Miocardio/terapia , Daño por Reperfusión Miocárdica/prevención & control , Reperfusión Miocárdica , Miocardio/metabolismo , Consumo de Oxígeno , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Animales , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Humanos , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Reperfusión Miocárdica/efectos adversos , Daño por Reperfusión Miocárdica/metabolismo , Daño por Reperfusión Miocárdica/patología , Daño por Reperfusión Miocárdica/fisiopatología , Miocardio/patología , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Recuperación de la Función , Factores de Riesgo , Resultado del Tratamiento
9.
Artif Organs ; 43(2): 125-131, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30216467

RESUMEN

Hemolysis is a potential limitation of percutaneously delivered left-sided mechanical circulatory support pumps, including trans valvular micro-axial flow pumps (TVP). Hemolytic biomarkers among durable left ventricular assist devices include lactate dehydrogenase (LDH) >2.5 times the upper limit of normal (ULN) and plasma-free hemoglobin (pf-Hb) >20 mg/dL. We examined the predictive value of these markers among patients with cardiogenic shock (CS) receiving a TVP. We retrospectively studied records of 116 consecutive patients receiving an Impella TVP at our institution between 2012 and 2017 for CS. Twenty-three met inclusion/exclusion criteria, and had sufficient pf-Hb data for analysis. Area under receiver-operator characteristic (ROC) curve for diagnosing hemolysis were calculated. Mean age was 62 ± 14 years and ejection fraction was 15 ± 5%. Mean duration of support was 5.4 ± 3.5 days. Pre-device LDH levels were >2.5x ULN in 71% (n = 5/7) of 5.0 and 29% of CP patients, while pre-device pf-Hb levels were >20 mg/dL in 14% (n = 1/7) of 5.0 and 25% (n = 4/16) of CP patients. Given elevated baseline LDH and pf-Hb levels, we defined hemolysis as a pf-Hb level >40 mg/dL within 72 h post-implant plus clinical evidence of device-related hemolysis. We identified that 30% (n = 7/23) had device-related hemolysis. Using ROC curve-derived cut-points, an increase in delta pf-Hb by >27mg/dL, not delta LDH, within 24 h after TVP implant (delta pf-Hb: C-statistic = 0.79, sensitivity: 57%, specificity: 93%, p <0.05) was highly predictive of hemolysis. In conclusion, we identified a change in pf-Hb, not LDH, levels is highly sensitive and specific for hemolysis in patients treated with a TVP for CS.


Asunto(s)
Corazón Auxiliar/efectos adversos , Hemoglobinas/análisis , Hemólisis/fisiología , Choque Cardiogénico/terapia , Anciano , Femenino , Pruebas Hematológicas , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Choque Cardiogénico/sangre
10.
F1000Res ; 72018.
Artículo en Inglés | MEDLINE | ID: mdl-30542612

RESUMEN

Heart failure is a major cause of global morbidity and mortality. Acute myocardial infarction (AMI) is a primary cause of heart failure due in large part to residual myocardial damage despite timely reperfusion therapy. Since the 1970's, multiple preclinical laboratories have tested whether reducing myocardial oxygen demand with a mechanical support pump can reduce infarct size in AMI. In the past decade, this hypothesis has been studied using contemporary circulatory support pumps. We will review the most recent series of preclinical studies in the field which led to the recently completed Door to Unload ST-segment Elevation Myocardial Infarction (DTU-STEMI) safety and feasibility pilot trial.


Asunto(s)
Corazón Auxiliar/tendencias , Infarto del Miocardio con Elevación del ST/terapia , Investigación Biomédica Traslacional/métodos , Animales , Humanos , Recuperación de la Función , Investigación Biomédica Traslacional/tendencias , Función Ventricular Izquierda
11.
Circ Heart Fail ; 11(8): e005115, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30354560

RESUMEN

BACKGROUND: Acute heart failure refractory to medical therapy is a major cause of morbidity and mortality. The Aortix device (Procyrion Inc) is a percutaneously delivered entrainment pump positioned in the descending aorta. METHODS AND RESULTS: Using the newest generation Aortix device in 8 adult male Yorkshire swine, we tested the hypothesis that positioning in the abdominal aorta may provide superior hemodynamic effects than thoracic positioning in a swine model of postinfarct left ventricular injury.Abdominal activation generated significantly larger transaortic gradients (proximal minus distal mean aortic pressures) than thoracic positioning at all pump speeds. Compared with baseline values, activation in the abdominal, not thoracic, position significantly increased cardiac output, reduced arterial elastance, and systemic vascular resistance at low speeds. Compared with baseline values, abdominal activation also increased transpulmonary pressure gradients at medium and high speed, which was driven by trends toward higher mean pulmonary artery pressure and lower pulmonary capillary wedge pressure. CONCLUSIONS: This is the first report to determine that in contrast to thoracic positioning, abdominal positioning of the newest generation Aortix device reduces left ventricular afterload and increases cardiac output at low speeds. These findings have potentially important implications for the design of early clinical studies by suggesting that device position and speed are major determinants of improved hemodynamic efficacy.


Asunto(s)
Aorta Abdominal/fisiopatología , Gasto Cardíaco , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/métodos , Función Ventricular Izquierda , Animales , Aorta Torácica/fisiopatología , Presión Arterial , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Masculino , Diseño de Prótesis , Recuperación de la Función , Sus scrofa , Factores de Tiempo
12.
J Card Fail ; 24(10): 706-710, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30244180

RESUMEN

BACKGROUND: Myocarditis complicated by cardiogenic shock remains a complex problem. The use of acute mechanical circulatory support devices for cardiogenic shock is growing. We explored the utility of Impella transvalvular microaxial flow catheters in the setting of myocarditis with cardiogenic shock. METHODS AND RESULTS: We retrospectively analyzed data from 21 sites within the cVAD registry, an ongoing multicenter voluntary registry at sites in North America and Europe that have used Impella in patients with myocarditis. Myocarditis was defined by endomyocardial biopsy (n = 11) or by clinical history without angiographic evidence of coronary disease (n = 23). A total of 34 patients received an Impella 2.5, CP, 5.0, or RP device for cardiogenic shock complicating myocarditis. Baseline characteristics included age 42 ± 17 years, left ventricular ejection fraction (LVEF) 18% ± 10%, cardiac index 1.82 ± 0.46 L·min-1·m-2, pulmonary capillary wedge pressure 25 ± 7 mm Hg, and lactate 27 ± 31 mg/dL. Before Impella placement, 32% (n = 11) of patients required intra-aortic balloon pump. Mean duration of Impella support was 91 ± 74 hours; 21 of 34 patients (62%) survived the index hospitalization and were discharged with an improved mean LVEF of 37.32% ± 20.31% (P = .001); 15 patients recovered with successful support, 5 patients were transferred to another hospital on initial Impella support, 1 patient underwent orthotopic heart transplantation. Ten patients required transition to another mechanical circulatory support device. CONCLUSIONS: This is the largest analysis of Impella-supported myocarditis cases to date. The use of Impella appears to be safe and effective in the settings of myocarditis complicated by cardiogenic shock.


Asunto(s)
Catéteres Cardíacos , Corazón Auxiliar , Miocarditis/complicaciones , Sistema de Registros , Choque Cardiogénico/terapia , Adulto , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Miocarditis/fisiopatología , Miocarditis/terapia , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/fisiopatología , Volumen Sistólico/fisiología , Resultado del Tratamiento
13.
J Am Coll Cardiol ; 72(5): 501-514, 2018 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-30049311

RESUMEN

BACKGROUND: Heart failure after an acute myocardial infarction (AMI) is a major cause of morbidity and mortality worldwide. We recently reported that activation of a transvalvular axial-flow pump in the left ventricle and delaying myocardial reperfusion, known as primary unloading, limits infarct size after AMI. The mechanisms underlying the cardioprotective benefit of primary unloading and whether the acute decrease in infarct size results in a durable reduction in LV scar and improves cardiac function remain unknown. OBJECTIVES: This study tested the importance of LV unloading before reperfusion, explored cardioprotective mechanisms, and determined the late-term impact of primary unloading on myocardial function. METHODS: Adult male swine were subjected to primary reperfusion or primary unloading after 90 min of percutaneous left anterior descending artery occlusion. RESULTS: Compared with primary reperfusion, 30 min of LV unloading was necessary and sufficient before reperfusion to limit infarct size 28 days after AMI. Compared with primary reperfusion, primary unloading increased expression of genes associated with cellular respiration and mitochondrial integrity within the infarct zone. Primary unloading for 30 min further reduced activity levels of proteases known to degrade the cardioprotective cytokine, stromal-derived factor (SDF)-1α, thereby increasing SDF-1α signaling via reperfusion injury salvage kinases, which limits apoptosis within the infarct zone. Inhibiting SDF-1α activity attenuated the cardioprotective effect of primary unloading. Twenty-eight days after AMI, primary unloading reduced LV scar size, improved cardiac function, and limited expression of biomarkers associated with heart failure and maladaptive remodeling. CONCLUSIONS: The authors report for the first time that first mechanically reducing LV work before coronary reperfusion with a transvalvular pump is necessary and sufficient to reduce infarct size and to activate a cardioprotective program that includes enhanced SDF-1α activity. Primary unloading further improved LV scar size and cardiac function 28 days after AMI.


Asunto(s)
Infarto del Miocardio/fisiopatología , Infarto del Miocardio/terapia , Reperfusión Miocárdica/métodos , Recuperación de la Función/fisiología , Función Ventricular Izquierda/fisiología , Animales , Masculino , Reperfusión Miocárdica/tendencias , Porcinos
14.
J Am Coll Cardiol ; 72(5): 569-580, 2018 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-30056830

RESUMEN

Myocardial injury induces significant changes in ventricular structure and function at both the cellular and anatomic level, leading to ventricular remodeling and subsequent heart failure. Unloading left ventricular pressure has been studied in both the short-term and long-term settings, as a means of preventing or reversing cardiac remodeling. In acute myocardial infarction, cardiac unloading is used to reduce oxygen demand and limit infarct size. Research has demonstrated the benefits of short-term unloading with mechanical circulatory support devices before reperfusion in the context of acute myocardial infarction with cardiogenic shock, and a confirmatory trial is ongoing. In chronic heart failure, ventricular unloading using mechanical circulatory support can reverse many of the cellular and anatomic changes that accompany ventricular remodeling. Ongoing research is evaluating the ability of left ventricular assist devices to promote myocardial recovery and remission from clinical heart failure.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Infarto del Miocardio/fisiopatología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular/fisiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia
15.
Catheter Cardiovasc Interv ; 91(7): 1192-1193, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29894593

RESUMEN

Rising urine NGAL and serum creatinine after 48 hr are potentially useful in predicting persistent creatinine increase in patients with contrast-induced AKI. Urinary NGAL may allow for early identification of a high-risk cohort following PCI. Future studies are needed to determine whether renal biomarkers are affected by clinical variables, such as heart failure acute mechanical circulatory support (AMCS) and whether they can be used to identify patients who would benefit from either AMCS reno-protection during PCI remains unknown.


Asunto(s)
Lesión Renal Aguda , Intervención Coronaria Percutánea , Proteínas de Fase Aguda , Biomarcadores , Creatinina , Humanos , Lipocalina 2 , Lipocalinas , Proteínas Proto-Oncogénicas
16.
J Heart Lung Transplant ; 37(1): 100-106, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29056460

RESUMEN

BACKGROUND: Prognosis is poor for patients with decompensated advanced heart failure (HF) refractory to medical therapy. Evaluating candidacy for durable mechanical circulatory support (MCS), cardiac transplantation, or palliative care is complex, and time is often needed to stabilize the patient hemodynamically. The Impella 5.0 (Abiomed, Danvers, MA) is a minimally invasive axial-flow catheter capable of providing full temporary hemodynamic support. We report a multicenter series on the use of this device for bridge to decision (BTD) in decompensated advanced HF patients. METHODS: In a retrospective evaluation at 3 centers of patients with advanced HF who acutely decompensated and received the Impella 5.0 for BTD, we analyzed demographics, procedural characteristics, in-hospital and intermediate-term outcomes, and in-hospital complications. RESULTS: There were 58 patients who met inclusion criteria from 2010 to 2015. All were inotrope dependent. The mean ejection fraction was 13%, and median age was 59 years (interquartile range, 48-64 years). Mean duration of support was 7 days (range, 0-22 days). Thirty-nine patients survived to next therapy (67%), with most receiving durable MCS (n = 20) or heart transplantation (n = 15). In-hospital complications included bleeding (n = 9) and hemolysis (n = 4). Of patients who survived to the next therapy, 1-year survival was 65% for those who received durable MCS, 87% for those who received a transplant, and 75% for those who were stabilized and weaned. CONCLUSIONS: The Impella 5.0 may provide a BTD strategy for patients with advanced HF and acute hemodynamic instability. Prospective studies are needed to evaluate the safety and effectiveness of this device in this patient population.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Enfermedad Aguda , Toma de Decisiones Clínicas , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo
17.
J Card Fail ; 23(8): 606-614, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28554716

RESUMEN

BACKGROUND: The utility of intra-aortic balloon counterpulsation pumps (IABPs) in low cardiac output states is unknown and no studies have explored the impact of IABP therapy on ventricular workload in patients with advanced heart failure (HF). For these reasons, we explored the acute hemodynamic effects of IABP therapy in patients with advanced HF. METHODS: We prospectively studied 10 consecutive patients with stage D HF referred for IABP placement before left ventricular assist device (LVAD) surgery and compared with 5 control patients with preserved left ventricular (LV) ejection fraction (EF) who did not receive IABP therapy. Hemodynamics were recorded using LV conductance and pulmonary artery catheters. Cardiac index (CI)-responder and CI-nonresponder status was assigned a priori as being "equal to or above" or below the median of the IABP effect on CI, respectively, within 24 hours after IABP activation. RESULTS: Compared with controls, patients with advanced HF had lower LVEF, lower LV end-systolic pressure, lower LV stroke work, and higher LV end-diastolic pressures and volumes before IABP activation. IABP activation reduced LV stroke work primarily by reducing end-systolic pressure. IABP therapy increased CI by a median of 20% as well as increased diastolic pressure time index and the myocardial oxygen supply:demand ratio. Compared with CI-nonresponders, CI-responders had higher systemic vascular resistance, lower right heart filling pressures, and a trend toward lower left heart filling pressures with improved indices of right heart function. Compared with CI-nonresponders, the diastolic pressure time index was increased among CI-responders. CONCLUSIONS: IABP therapy may be effective at reducing LV stroke work, increasing CI, and favorably altering the myocardial oxygen supply:demand ratio in patients with advanced HF, especially among patients with low right heart filling pressures and high systemic vascular resistance.


Asunto(s)
Contrapulsación/tendencias , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Contrapulsador Intraaórtico/tendencias , Adulto , Anciano , Contrapulsación/métodos , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Contrapulsador Intraaórtico/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA