1.
Artículo en Inglés | MEDLINE | ID: mdl-39248471

RESUMEN

BACKGROUND AND OBJECTIVES: Distal nerve transfers for muscle reinnervation and restoration of function after upper and lower motor neuron lesions are a well-established surgical approach. The brachialis to anterior interosseous nerve (BrAIN) transfer is performed for prehension reanimation in lower brachial plexus and traumatic cervical spinal cord injuries. The aim of the study is to shed light on the inconsistent results observed in patients who undergo the BrAIN transfer. METHODS: An anatomic dissection was conducted on 30 fresh upper limb specimens to examine the intraneural topography of the median nerve (MN) in the upper arm at the level of the BrAIN transfer and the presence of intraneural fascicular interconnections distally. RESULTS: Fascicular interconnections between the AIN and other MN branches were consistently found in the distal third of the upper arm. The first interconnection was at 3.85 ± 1.82 cm proximal to the interepicondylar line, and the second one, after further proximal neurolysis, was at 9.45 ± 1.16 cm from the interepicondylar line. Intraneural topography of the AIN at the transfer level varied, with dorsomedial, dorsolateral, and purely dorsal locations observed. CONCLUSION: Consistent fascicular interconnections between the AIN and MN branches and intraneural topography variability of the MN may lead to aberrant reinnervation.

2.
Wien Klin Wochenschr ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39172198

RESUMEN

INTRODUCTION: An increasing number of high voltage electric burn injuries in a typically younger patient collective of train surfers and climbers at our level I center for burns was recognized. The purpose of this study was a retrospective data evaluation and as a consequence the implementation of an awareness program against train surfing. MATERIAL AND METHODS: In a retrospective analysis of prospectively collected data, 17 patients with high voltage injuries, who had been treated at our unit between January 2022 and January 2023, were identified. Of these patients seven were treated for injuries due to train surfing or climbing and therefore included in this study. The patients were assessed clinically for total burn surface area (TBSA), degree of burn, associated Injuries, hospital length of stay, number and type of surgeries (fasciotomy, minor/major amputations, defect coverage split skin graft or flaps). RESULTS: A total of seven males formed the basis of this report with an average age of 17.7 years (range 14-21 years). The highest ABSI (Abbreviated Burn Severity Index) score was 12, leading to the death of the 21-year-old patient who had 80% TBSA as well as multiple comorbidities including severe brain damage. The mean duration of stay at the intensive care unit (ICU) was 24.8 days and the mortality rate was 14.29%. CONCLUSION: This study highlighted the severity of injuries, with a mean TBSA of 41.42% and a mortality rate of 14.29% among the study population. Train climbing and surfing patients presented with severe injuries and fatal long-term consequences. A pilot project involving several stakeholders was initiated in order to raise awareness of the dangers of electric arcs and the risk involved.

3.
Nat Commun ; 15(1): 5337, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914540

RESUMEN

Neuromuscular control of bionic arms has constantly improved over the past years, however, restoration of sensation remains elusive. Previous approaches to reestablish sensory feedback include tactile, electrical, and peripheral nerve stimulation, however, they cannot recreate natural, intuitive sensations. Here, we establish an experimental biological sensorimotor interface and demonstrate its potential use in neuroprosthetics. We transfer a mixed nerve to a skeletal muscle combined with glabrous dermal skin transplantation, thus forming a bi-directional communication unit in a rat model. Morphological analyses indicate reinnervation of the skin, mechanoreceptors, NMJs, and muscle spindles. Furthermore, sequential retrograde labeling reveals specific sensory reinnervation at the level of the dorsal root ganglia. Electrophysiological recordings show reproducible afferent signals upon tactile stimulation and tendon manipulation. The results demonstrate the possibility of surgically creating an interface for both decoding efferent motor control, as well as encoding afferent tactile and proprioceptive feedback, and may indicate the way forward regarding clinical translation of biological communication pathways for neuroprosthetic applications.


Asunto(s)
Biónica , Músculo Esquelético , Animales , Ratas , Músculo Esquelético/inervación , Músculo Esquelético/fisiología , Retroalimentación Sensorial/fisiología , Propiocepción/fisiología , Ganglios Espinales/fisiología , Mecanorreceptores/fisiología , Husos Musculares/fisiología , Masculino , Femenino , Tacto/fisiología , Piel/inervación
4.
Plast Reconstr Surg Glob Open ; 12(5): e5850, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38808147

RESUMEN

Background: Upper extremity limb loss profoundly impacts a patient's quality of life and well-being and carries a significant societal cost. Although osseointegration allows the attachment of the prosthesis directly to the bone, it is a relatively recent development as an alternative to conventional socket prostheses. The objective of this review was to identify reports on osseointegrated prosthetic embodiment for transhumeral amputations and assess the implant systems used, postoperative outcomes, and complications. Methods: A systematic review following PRISMA and AMSTAR guidelines assessed functional outcomes, implant longevity and retention, activities of daily living, and complications associated with osseointegrated prostheses in transhumeral amputees. Results: The literature search yielded 794 articles, with eight of these articles (retrospective analyses and case series) meeting the inclusion criteria. Myoelectric systems equipped with Osseointegrated Prostheses for the Rehabilitation of Amputees implants have been commonly used as transhumeral osseointegration systems. The transhumeral osseointegrated prostheses offered considerable improvements in functional outcomes, with participants demonstrating enhanced range of motion and improved performance of activities compared with traditional socket-based prostheses. One study demonstrated the advantage of an osseointegrated implant as a bidirectional gateway for signal transmission, enabling intuitive control of a bionic hand. Conclusions: Osseointegrated prostheses hold the potential to significantly improve the quality of life for individuals with transhumeral amputations. Continued research and clinical expansion are expected to lead to the realization of enhanced efficacy and safety in this technique, accompanied by cost reductions over time as a result of improved efficiencies and advancements in device design.

5.
J Rehabil Med ; 56: jrm34141, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38770700

RESUMEN

OBJECTIVE: To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees. DESIGN: Case series. PATIENTS: Three male patients with a unilateral traumatic transhumeral amputation. METHODS: Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthesis training, and controlling the actual device. The impairment in daily life, health-related quality of life, and pain before and after the intervention was evaluated in these patients. Their shoulder range of motion, prosthesis embodiment, and function were documented at a 2- to 5-year follow-up. RESULTS: All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of abduction and 45° of anteversion. They became more independent in their daily life activities after the intervention and incorporated their prosthesis into their body scheme to a high extent. CONCLUSION: These results indicate that patients can benefit from the combined procedure. However, the patients' perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure need to be incorporated in the decision-making.


Asunto(s)
Amputados , Miembros Artificiales , Transferencia de Nervios , Oseointegración , Rango del Movimiento Articular , Humanos , Masculino , Oseointegración/fisiología , Adulto , Amputados/rehabilitación , Transferencia de Nervios/métodos , Rango del Movimiento Articular/fisiología , Biónica , Resultado del Tratamiento , Músculo Esquelético , Persona de Mediana Edad , Húmero/cirugía , Calidad de Vida , Amputación Traumática/rehabilitación , Amputación Traumática/cirugía , Actividades Cotidianas
6.
Sci Robot ; 9(90): eadl0085, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809994

RESUMEN

Sensory feedback for prosthesis control is typically based on encoding sensory information in specific types of sensory stimuli that the users interpret to adjust the control of the prosthesis. However, in physiological conditions, the afferent feedback received from peripheral nerves is not only processed consciously but also modulates spinal reflex loops that contribute to the neural information driving muscles. Spinal pathways are relevant for sensory-motor integration, but they are commonly not leveraged for prosthesis control. We propose an approach to improve sensory-motor integration for prosthesis control based on modulating the excitability of spinal circuits through the vibration of tendons in a closed loop with muscle activity. We measured muscle signals in healthy participants and amputees during different motor tasks, and we closed the loop by applying vibration on tendons connected to the muscles, which modulated the excitability of motor neurons. The control signals to the prosthesis were thus the combination of voluntary control and additional spinal reflex inputs induced by tendon vibration. Results showed that closed-loop tendon vibration was able to modulate the neural drive to the muscles. When closed-loop tendon vibration was used, participants could achieve similar or better control performance in interfaces using muscle activation than without stimulation. Stimulation could even improve prosthetic grasping in amputees. Overall, our results indicate that closed-loop tendon vibration can integrate spinal reflex pathways in the myocontrol system and open the possibility of incorporating natural feedback loops in prosthesis control.


Asunto(s)
Amputados , Miembros Artificiales , Retroalimentación Sensorial , Mano , Músculo Esquelético , Diseño de Prótesis , Reflejo , Vibración , Humanos , Adulto , Mano/fisiología , Masculino , Femenino , Retroalimentación Sensorial/fisiología , Reflejo/fisiología , Músculo Esquelético/fisiología , Músculo Esquelético/inervación , Electromiografía , Tendones/fisiología , Neuronas Motoras/fisiología , Persona de Mediana Edad , Fuerza de la Mano/fisiología , Adulto Joven
7.
Brain Stimul ; 17(3): 510-524, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38677543

RESUMEN

BACKGROUND: Electrical stimulation of the vagus nerve (VN) is a therapy for epilepsy, obesity, depression, and heart diseases. However, whole nerve stimulation leads to side effects. We examined the neuroanatomy of the mid-cervical segment of the human VN and its superior cardiac branch to gain insight into the side effects of VN stimulation and aid in developing targeted stimulation strategies. METHODS: Nerve specimens were harvested from eight human body donors, then subjected to immunofluorescence and semiautomated quantification to determine the signature, quantity, and spatial distribution of different axonal categories. RESULTS: The right and left cervical VN (cVN) contained a total of 25,489 ± 2781 and 23,286 ± 3164 fibers, respectively. Two-thirds of the fibers were unmyelinated and one-third were myelinated. About three-quarters of the fibers in the right and left cVN were sensory (73.9 ± 7.5 % versus 72.4 ± 5.6 %), while 13.2 ± 1.8 % versus 13.3 ± 3.0 % were special visceromotor and parasympathetic, and 13 ± 5.9 % versus 14.3 ± 4.0 % were sympathetic. Special visceromotor and parasympathetic fibers formed clusters. The superior cardiac branches comprised parasympathetic, vagal sensory, and sympathetic fibers with the left cardiac branch containing more sympathetic fibers than the right (62.7 ± 5.4 % versus 19.8 ± 13.3 %), and 50 % of the left branch contained sensory and sympathetic fibers only. CONCLUSION: The study indicates that selective stimulation of vagal sensory and motor fibers is possible. However, it also highlights the potential risk of activating sympathetic fibers in the superior cardiac branch, especially on the left side.


Asunto(s)
Nervio Vago , Humanos , Nervio Vago/fisiología , Nervio Vago/anatomía & histología , Masculino , Femenino , Persona de Mediana Edad , Adulto , Fibras Nerviosas/fisiología , Corazón/inervación , Corazón/fisiología , Corazón/anatomía & histología , Estimulación del Nervio Vago/métodos , Anciano
8.
J Vis Exp ; (205)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38526122

RESUMEN

Over the past decade, the field of prosthetics has witnessed significant progress, particularly in the development of surgical techniques to enhance the functionality of prosthetic limbs. Notably, novel surgical interventions have had an additional positive outcome, as individuals with amputations have reported neuropathic pain relief after undergoing such procedures. Subsequently, surgical techniques have gained increased prominence in the treatment of postamputation pain, including one such surgical advancement - targeted muscle reinnervation (TMR). TMR involves a surgical approach that reroutes severed nerves as a type of nerve transfer to "target" motor nerves and their accompanying motor end plates within nearby muscles. This technique originally aimed to create new myoelectric sites for amplified electromyography (EMG) signals to enhance prosthetic intuitive control. Subsequent work showed that TMR also could prevent the formation of painful neuromas as well as reduce postamputation neuropathic pain (e.g., Residual and Phantom Limb Pain). Indeed, multiple studies have demonstrated TMR's effectiveness in mitigating postamputation pain as well as improving prosthetic functional outcomes. However, technical variations in the procedure have been identified as it is adopted by clinics worldwide. The purpose of this article is to provide a detailed step-by-step description of the TMR procedure, serving as the foundation for an international, randomized controlled trial (ClinicalTrials.gov, NCT05009394), including nine clinics in seven countries. In this trial, TMR and two other surgical techniques for managing postamputation pain will be evaluated.


Asunto(s)
Neuralgia , Miembro Fantasma , Humanos , Amputación Quirúrgica , Músculo Esquelético/inervación , Procedimientos Neuroquirúrgicos , Miembro Fantasma/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
J Hand Surg Eur Vol ; 49(6): 783-791, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38366374

RESUMEN

Selective nerve transfers are used in the setting of upper limb amputation to improve myoelectric prosthesis control. This surgical concept is referred to as targeted muscle reinnervation (TMR) and describes the rerouting of the major nerves of the arm onto the motor branches of the residual limb musculature. Aside from providing additional myosignals for prosthetic control, TMR can treat and prevent neuroma pain and possibly also phantom limb pain. This article reviews the history and current applications of TMR in upper limb amputation, with a focus on practical considerations. It further explores and identifies technological innovations to improve the man-machine interface in amputation care, particularly regarding implantable interfaces, such as muscle electrodes and osseointegration. Finally, future clinical directions and possible scientific avenues in this field are presented and critically discussed.


Asunto(s)
Miembros Artificiales , Biónica , Músculo Esquelético , Transferencia de Nervios , Extremidad Superior , Humanos , Transferencia de Nervios/métodos , Extremidad Superior/inervación , Extremidad Superior/cirugía , Músculo Esquelético/inervación , Músculo Esquelético/cirugía , Músculo Esquelético/trasplante , Amputación Quirúrgica
10.
Handchir Mikrochir Plast Chir ; 56(1): 84-92, 2024 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-38417811

RESUMEN

BACKGROUND: The upper extremity and particularly the hands are crucial for patients in interacting with their environment, therefore amputations or severe damage with loss of hand function significantly impact their quality of life. In cases where biological reconstruction is not feasible or does not lead to sufficient success, bionic reconstruction plays a key role in patient care. Classical myoelectric prostheses are controlled using two signals derived from surface electrodes in the area of the stump muscles. Prosthesis control, especially in high amputations, is then limited and cumbersome. The surgical technique of Targeted Muscle Reinnervation (TMR) offers an innovative solution: The major arm nerves that have lost their target organs due to amputation are rerouted to muscles in the stump area. This enables the establishment of cognitive control signals that allow significantly improved prosthesis control. PATIENTS/MATERIALS AND METHODS: A selective literature review on TMR and bionic reconstruction was conducted, incorporating relevant articles and discussing them considering the clinical experience of our research group. Additionally, a clinical case is presented. RESULTS: Bionic reconstruction combined with Targeted Muscle Reinnervation enables intuitive prosthetic control with simultaneous movement of various prosthetic degrees of freedom and the treatment of neuroma and phantom limb pain. Long-term success requires a high level of patient compliance and intensive signal training during the prosthetic rehabilitation phase. Despite technological advances, challenges persist, especially in enhancing signal transmission and integrating natural sensory feedback into bionic prostheses. CONCLUSION: TMR surgery represents a significant advancement in the bionic care of amputees. Employing selective nerve transfers for signal multiplication and amplification, opens up possibilities for improving myoelectric prosthesis function and thus enhancing patient care. Advances in the area of external prosthetic components, improvements in the skeletal connection due to osseointegration and more fluid signal transmission using wireless, fully implanted electrode systems will lead to significant progress in bionic reconstruction, both in terms of precision of movement and embodiment.


Asunto(s)
Miembros Artificiales , Calidad de Vida , Humanos , Amputación Quirúrgica , Extremidad Superior/cirugía , Muñones de Amputación/cirugía , Muñones de Amputación/inervación , Implantación de Prótesis , Músculo Esquelético/cirugía
11.
Sci Adv ; 10(9): eadj3872, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38416828

RESUMEN

Advances in robotics have outpaced the capabilities of man-machine interfaces to decipher and transfer neural information to and from prosthetic devices. We emulated clinical scenarios where high- (facial) or low-neural capacity (ulnar) donor nerves were surgically rewired to the sternomastoid muscle, which is controlled by a very small number of motor axons. Using retrograde tracing and electrophysiological assessments, we observed a nearly 15-fold functional hyper-reinnervation of the muscle after high-capacity nerve transfer, demonstrating its capability of generating a multifold of neuromuscular junctions. Moreover, the surgically redirected axons influenced the muscle's physiological characteristics, by altering the expression of myosin heavy-chain types in alignment with the donor nerve. These findings highlight the remarkable capacity of skeletal muscles to act as biological amplifiers of neural information from the spinal cord for governing bionic prostheses, with the potential of expressing high-dimensional neural function for high-information transfer interfaces.


Asunto(s)
Neuronas Motoras , Regeneración Nerviosa , Humanos , Neuronas Motoras/fisiología , Regeneración Nerviosa/fisiología , Músculo Esquelético , Nervios Periféricos , Axones/fisiología
14.
Arch Clin Cases ; 10(4): 200-204, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38155995

RESUMEN

Paget-Schroetter syndrome (PSS) is relatively rare condition of thoracic outlet syndrome characterized by thrombosis or blood clot formation in the subclavian vein. Due to the non-specific symptoms and low incidence rate, PSS is frequently missed by medical professionals, and as such it often leads to wrong diagnosis and untreated patients. We present the case of a 30-year-old CrossFit trainer who developed a thrombosis of the subclavian vein. Initially, the patient consulted an internist after experiencing swelling in the right shoulder region and discoloration of the right upper extremity. Angiography revealed occlusion of the subclavian vein and anticoagulant therapy was prescribed. For more than a year, the patient's symptoms remained unchanged, and the subclavian vein occlusion persisted. Venography suspected effort thrombosis of the subclavian vein. The patient underwent surgery for decompression of the subclavian vein. After six months, results from post-operative computed tomography angiography showed that venous flow was fully restored and no pathology of the venous vessel wall could be demonstrated. This report aims to increase awareness of PSS among medical professionals, leading to earlier diagnosis and adequate clinical-surgical management.

15.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37941253

RESUMEN

Small obstacles on the ground often lead to a fall when caught with commercial prosthetic feet. Despite some recently developed feet can actively control the ankle angle, for instance over slopes, their flat and rigid sole remains a cause of instability on uneven grounds. Soft robotic feet were recently proposed to tackle that issue; however, they lack consistent experimental validation. Therefore, this paper describes the experimental setup realized to test soft and rigid prosthetic feet with lower-limb prosthetic users. It includes a wooden walkway and differently shaped obstacles. It was preliminary validated with an able-bodied subject, the same subject walking on commercial prostheses through modified walking boots, and with a prosthetic user. They performed walking firstly on even ground, and secondly on even ground stepping on one of the obstacles. Results in terms of vertical ground reaction force and knee moments in both the sagittal and frontal planes show how the poor performance of commonly used prostheses is exacerbated in case of obstacles. The prosthetic user, indeed, noticeably relies on the sound leg to compensate for the stiff and unstable interaction of the prosthetic limb with the obstacle. Therefore, since the limitations of non-adaptive prosthetic feet in obstacle-dealing emerge from the experiments, as expected, this study justifies the use of the setup for investigating the performance of soft feet on uneven grounds and obstacle negotiation.


Asunto(s)
Amputados , Miembros Artificiales , Humanos , Marcha , Fenómenos Biomecánicos , Pie , Caminata , Diseño de Prótesis
16.
Microsurgery ; 43(7): 717-721, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37349939

RESUMEN

Distal nerve transfers to restore elbow flexion have become standard of care in brachial plexus reconstruction. The purpose of this report is to draw attention to intractable co-contraction as a rare but significant adverse event of distal nerve transfers. Here we report of treatment of a disabling co-contraction of the brachialis muscle and wrist/finger flexors after median to brachialis fascicular transfer in a 61-year-old male patient. The primary injury was an postganglionic lesion of roots C5/C6 and a preganglionic injury of C7/C8 with intact root Th1 after a motor bicycle accident. After upper brachial plexus reconstruction (C5/C6 to suprascapular nerve and superior trunk) active mobility in the shoulder joint (supraspinatus, deltoid) could be restored. However, due to lacking motor recovery of elbow flexion the patient underwent additional median to brachialis nerve transfer. Shortly after, active elbow flexion commenced with rapid recovery to M4 at 9 months postoperatively. However, despite intensive EMG triggered physiotherapy the patient could not dissociate hand from elbow function and was debilitated by this iatrogenic co-contraction. After preoperative ultrasound-guided block resulted in preserved biceps function, the previously transferred median nerve fascicle was reversed. This was done by dissecting the previous nerve transfer of the median nerve fascicle to the brachialis muscle branch and adapting the fascicles to their original nerve. Postoperatively, the patient was followed up for 10 months without a complication and maintained M4 elbow flexion with independent strong finger flexion. Distal nerve transfers are an excellent option to restore function, however, in some patients cognitive limitations may prevent cortical reorganization and lead to disturbing co-contractions.

17.
Front Neuroanat ; 17: 1198042, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37332322

RESUMEN

Basic behaviors, such as swallowing, speech, and emotional expressions are the result of a highly coordinated interplay between multiple muscles of the head. Control mechanisms of such highly tuned movements remain poorly understood. Here, we investigated the neural components responsible for motor control of the facial, masticatory, and tongue muscles in humans using specific molecular markers (ChAT, MBP, NF, TH). Our findings showed that a higher number of motor axonal population is responsible for facial expressions and tongue movements, compared to muscles in the upper extremity. Sensory axons appear to be responsible for neural feedback from cutaneous mechanoreceptors to control the movement of facial muscles and the tongue. The newly discovered sympathetic axonal population in the facial nerve is hypothesized to be responsible for involuntary control of the muscle tone. These findings shed light on the pivotal role of high efferent input and rich somatosensory feedback in neuromuscular control of finely adjusted cranial systems.

18.
J Pers Med ; 13(4)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37109045

RESUMEN

Negative expectations regarding nerve reconstruction in the elderly prevail in the literature, but little is known about the effectiveness of nerve transfers in patients with brachial plexus injuries aged over 60 years. We present a series of five patients (1 female, 4 male) aged between 60 and 81 years (median 62.0 years) who underwent nerve reconstruction using multiple nerve transfers in brachial plexopathies. The etiology of brachial plexus injury was trauma (n = 2), or iatrogenic, secondary to spinal surgical laminectomy, tumor excision and radiation for breast cancer (n = 3). All but one patient underwent a one-stage reconstruction including neurolysis and extra-anatomical nerve transfer alone (n = 2) or combined with anatomical reconstruction by sural nerve grafts (n = 2). One patient underwent a two-stage reconstruction, which involved a first stage anatomical brachial plexus reconstruction followed by a second stage nerve transfer. Neurotizations were performed as double (n = 3), triple (n = 1) or quadruple (n = 1) nerve or fascicular transfers. Overall, at least one year postoperatively, successful results, characterized by a muscle strength of M3 or more, were restored in all cases, two patients even achieving M4 grading in the elbow flexion. This patient series challenges the widely held dogma that brachial plexus reconstruction in older patients will produce poor outcomes. Distal nerve transfers are advantageous as they shorten the reinnervation distance. Healthy, more elderly patients should be judiciously offered the whole spectrum of reconstructive methods and postoperative rehabilitation concepts to regain useful arm and hand function and thus preserve independence after a traumatic or nontraumatic brachial plexus injury.

19.
Handchir Mikrochir Plast Chir ; 55(2): 140-147, 2023 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-37023761

RESUMEN

The treatment of peripheral nerve pathologies requires a rapid and precise diagnosis. However, the correct identification of nerve pathologies is often difficult and valuable time is lost in the process. In this position paper of the German-Speaking Group for Microsurgery of Peripheral Nerves and Vessels (DAM), we describe the current evidence for various perioperative diagnostics for the detection of traumatic peripheral nerve lesions or compression syndromes. In detail, we evaluated the importance of clinical examinations, electrophysiology, nerve ultrasound and magnetic resonance neurography. Additionally, we surveyed our members for their diagnostic approach in this regard. The statements are based on a consensus workshop on the 42nd meeting of the DAM in Graz, Austria.


Asunto(s)
Microcirugia , Nervios Periféricos , Humanos , Síndrome , Nervios Periféricos/cirugía , Austria , Imagen por Resonancia Magnética
20.
J Neurosurg ; 139(5): 1396-1404, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37029679

RESUMEN

OBJECTIVE: Intrinsic function is indispensable for dexterous hand movements. Distal ulnar nerve defects can result in intrinsic muscle dysfunction and sensory deficits. Although the ulnar nerve's fascicular anatomy has been extensively studied, quantitative and topographic data on motor axons traveling within this nerve remain elusive. METHODS: The ulnar nerves of 14 heart-beating organ donors were evaluated. The motor branches to the flexor carpi ulnaris (FCU) and flexor digitorum profundus (FDP) muscles and the dorsal branch (DoBUN) as well as 3 segments of the ulnar nerve were harvested in 2-cm increments. Samples were subjected to double immunofluorescence staining using antibodies against choline acetyltransferase and neurofilament. RESULTS: Samples revealed more than 25,000 axons in the ulnar nerve at the forearm level, with a motor axon proportion of only 5%. The superficial and DoBUN showed high axon numbers of more than 21,000 and 9300, respectively. The axonal mapping of more than 1300 motor axons revealed an increasing motor/sensory ratio from the proximal ulnar nerve (1:20) to the deep branch of the ulnar nerve (1:7). The motor branches (FDP and FCU) showed that sensory axons outnumber motor axons by a ratio of 10:1. CONCLUSIONS: Knowledge of the detailed axonal architecture of the motor and sensory components of the human ulnar nerve is of the utmost importance for surgeons considering fascicular grafting or nerve transfer surgery. The low number of efferent axons in motor branches of the ulnar nerve and their distinct topographical distribution along the distal course of the nerve is indispensable information for modern nerve surgery.


Asunto(s)
Transferencia de Nervios , Nervio Cubital , Humanos , Antebrazo/inervación , Músculo Esquelético/inervación , Codo , Axones/fisiología