Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Appl Opt ; 45(12): 2711-22, 2006 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-16633421

RESUMEN

We demonstrate in both simulated and real cases the effect that undersampling of a three-dimensional (3D) wrapped phase distribution has on the geometry of phase singularity loops and their branch cut surfaces. The more intuitive two-dimensional (2D) problem of setting branch cuts between dipole pairs is taken as a starting point, and then branch cut surfaces in flat and ambiguous 3D loops are discussed. It is shown that the correct 2D branch cuts and 3D branch cut surfaces should be placed where the gradient of the original phase distribution exceeded pi rad voxel(-1). This information, however, is lost owing to undersampling and cannot be recovered from the sampled wrapped phase distribution alone. As a consequence, empirical rules such as finding the surface of minimal area or methods based on the wrapped phase gradient will fail to find the correct branch cut surfaces. We conclude that additional information about the problem under study is therefore needed to produce correct branch cut surfaces that lead to an unwrapped phase distribution with minimum local errors. An example with real data is provided in which downsampled phase contrast magnetic resonance imaging data are successfully unwrapped when the position of the vessel walls and the physical properties of the flowing blood are taken into account.


Asunto(s)
Arterias/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Señales Asistido por Computador , Algoritmos , Arterias/anatomía & histología , Artefactos , Humanos , Almacenamiento y Recuperación de la Información/métodos , Imagen por Resonancia Cinemagnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad
2.
NMR Biomed ; 15(2): 99-105, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11870905

RESUMEN

The effects of two anti-vascular agents, combretastatin A4 phosphate (CA4P), and 5,6-dimethylxanthenone-4-acetic acid (DMXAA), on the perfusion of two human colon adenocarcinomas implanted in SCID mice, were assessed for up to 3 h using non-invasive magnetic resonance imaging (MRI) and spectroscopy techniques (MRS). MRI measurements of GdDTPA inflow showed that treatment with CA4P had little effect on the perfusion of HT29 tumours. Localized (31)P MRS measurements also showed that the drug had no significant effect on tumour cell energy status, as assessed from the ratio of the integrals of the signals from inorganic phosphate (P(i)) and nucleoside triphosphates. However, after treatment with DMXAA, perfusion was reduced and the P(i)/NTP ratio increased, indicating that the HT29 tumour is susceptible to the action of this drug. The LS174T tumour model was susceptible to both CA4P and DMXAA, using the criteria of changes in GdDTPA inflow and P(i)/NTP ratio.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Inhibidores de la Angiogénesis/uso terapéutico , Antineoplásicos Fitogénicos/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias del Colon/tratamiento farmacológico , Estilbenos/uso terapéutico , Xantenos/uso terapéutico , Xantonas , Adenocarcinoma/irrigación sanguínea , Adenocarcinoma/patología , Animales , Antineoplásicos/uso terapéutico , Neoplasias del Colon/irrigación sanguínea , Neoplasias del Colon/patología , Medios de Contraste , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Ratones , Ratones SCID , Trasplante Heterólogo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA