Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38705488

RESUMEN

PURPOSE: There is interest in using dual-energy computed tomography (DECT) to evaluate organ function before and after radiation therapy (RT). The purpose of this study (trial identifier: NCT04863027) is to assess longitudinal changes in lung perfusion using iodine maps derived from DECT in patients with lung cancer treated with conventional or stereotactic RT. METHODS AND MATERIALS: For 48 prospectively enrolled patients with lung cancer, a contrast-enhanced DECT using a dual-source CT simulator was acquired pretreatment and at 6 and 12 months posttreatment. Pulmonary functions tests (PFT) were obtained at baseline and at 6 and 12 months posttreatment. Iodine maps were extracted from the DECT images using a previously described 2-material decomposition framework. Longitudinal iodine maps were normalized using a reference region defined as all voxels with perfusion in the top 10% outside of the 5 Gy isodose volume. Normalized functional responses (NFR) were calculated for 3 dose ranges: <5, 5 to 20, and >20 Gy. Mixed model analysis was used to assess the correlation between dose metrics and NFR. Pearson correlation was used to assess if NFRs were correlated with PFT changes. RESULTS: Out of the 48 patients, 21 (44%) were treated with stereotactic body RT and 27 (56%) were treated with conventionally fractionated intensity-modulated RT. Thirty-one out of these 48 patients were ultimately included in data analysis. It was found that NFR is linearly correlated with dose (P < .001) for both groups. The number of months elapsed post-RT was also found to correlate with NFR (P = .029), although this correlation was not observed for the stereotactic body RT subgroup. The NFR was not found to correlate with PFT changes. CONCLUSIONS: DECT-derived iodine maps are a promising method for detailed anatomic evaluation of radiation effect on lung function, including potentially subclinical changes.

2.
J Contemp Brachytherapy ; 15(6): 453-464, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38230395

RESUMEN

Purpose: The addition of interstitial (IS) needles to intra-cavitary (IC) brachytherapy applicators is associated with improved outcomes in locally advanced cervical cancers involving parametrial tumor extensions. The purpose of this work was to validate a clinical workflow involving 3D-printed caps for a commercial IC split ring applicator that enable using IS needle trajectories tailored to each treatment. Material and methods: A dedicated software module was developed in this work allowing users to design patient-specific IS caps without knowledge of computer-aided design (CAD) software. This software module was integrated to 3D Brachy, a commercial software developed by Adaptiiv Medical Technologies Inc. For validation of the workflow, CAD models of ground truth caps with five IS needle trajectories were designed with Fusion 360™, 3D-printed, assembled with a split ring applicator, and CT-scanned with radio-opaque markers. 3D Brachy was then applied to generate a replica based on trajectories reconstructed from the radio-opaque markers. A comparison between ground truth and replicated IS needle trajectories was done using intersection points with planes at the level of the cervix (z = 0 cm) and a representative needle depth (z = 3 cm). Results: Prototypes of interstitial caps 3D-printed in both BioMed Amber and BioMed Clear SLA resins were tested to be functional both pre- and post-sterilization for IS needles with obliquity angles ≤ 45°. Distance-to-agreement at z = 0 cm and 3 cm as well as deviations in pitch and yaw angles of the five IS needle trajectories were found to have mean values of 3.3 ±2.1 mm, 7.3 ±2.0 mm, 2.9° ±2.3°, and 7.0° ±7.0°, respectively. Conclusions: The clinical workflow for image-guided adaptive cervical cancer brachytherapy using the Montreal split ring applicator was validated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA