1.
Perfusion ; 13(5): 346-52, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9778720

RESUMEN

Neurologic complications are already well documented after cardiopulmonary bypass (CPB) procedures in neonates and infants. Physiologic pulsatile flow CPB systems may be the alternative to the currently used steady-flow CPB circuits. In addition to the pulsatile pump, a membrane oxygenator should be chosen carefully, because only a few membrane oxygenators are suitable for physiologic pulsatile flow. We have tested four different types of neonate-infant membrane oxygenators for physiologic pulsatility with The University of Texas neonate-infant pulsatile CPB system in vitro. Evaluation criteria were based on mean ejection time, extracorporeal circuit (ECC) pressure, and upstroke of dp/dt. The results suggested that the Capiox 308 hollow-fibre membrane oxygenator produced the best physiologic pulsatile waveform according to the ejection time, ECC pressure, and the upstroke of dp/dt. The Minimax Plus and Masterflo Infant hollow-fibre membrane oxygenators also produced adequate pulsatile flow. Only the Variable Prime Cobe Membrane Lung (VPCML) Plus flat-sheet membrane oxygenator failed to reach the criteria for physiologic pulsatility. Depending on the oxygenator used, the lowest priming volume of the infant CPB circuit was 415 ml and the highest 520 ml.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenación por Membrana Extracorpórea/métodos , Oxigenadores de Membrana/normas , Complicaciones Posoperatorias/prevención & control , Encefalopatías/prevención & control , Preescolar , Humanos , Lactante
2.
ASAIO J ; 43(1): 13-8, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9116347

RESUMEN

Eleven goats (mean weight, 69 +/- 16 kg) underwent 5 hrs of normothermic nonpulsatile cardiopulmonary bypass (CPB) using as priming fluid either a Ringer's based crystalloid priming solution (CP, n = 5) of a hyperosmolar oxyreplete hemosubstitute (HS, n = 6). The HS contained 20% w/v perfluorocarbon (perfluorodecalin), its osmolarity was 800-900 mOsm/1, and the administered dose of perfluorocarbon was 30-50 ml/kg. Otherwise, the experimental procedure was identical for both groups. PaCO2 was maintained above 35 mmHg and blood flow rate at 65 ml/kg. Brain tissue pH, PO2, and PCO2, cerebral blood flow (CBF), arterial and venous blood gases, and other systemic variables were monitored. During CPB, PVO2 and brain tissue PO2 were increased significantly in the HS group. The CBF per kilogram of weight also was significantly higher in the HS group. Metabolic acidosis developed in both groups and, surprisingly, brain tissue pH and pHV were lower in the HS group. The mean values of PVCO2 and brain tissue PCO2 indicate that brain tissue hypercapnia also occurred in both groups. The HS provided long-term stability and compatibility with electrolytes, and did not cause major complications or allergic reactions during CPB. Perfluorocarbon based HSs improve tissue oxygenation, eliminate the risk of infection due to homologous transfusions, do not require blood type matching, have a shelf life longer than that of blood, and, therefore, they can be an important factor in diminishing the incidence of complications after CPB.


Asunto(s)
Sustitutos Sanguíneos/farmacología , Encéfalo/metabolismo , Dióxido de Carbono/sangre , Puente Cardiopulmonar , Circulación Cerebrovascular/efectos de los fármacos , Fluorocarburos/farmacología , Oxígeno/sangre , Animales , Cabras , Concentración de Iones de Hidrógeno
3.
Int J Artif Organs ; 19(3): 170-6, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8675361

RESUMEN

Cardiopulmonary bypass surgical techniques that allow a surgeon to operate on the infant's heart use an extracorporeal circuit consisting of a pump, oxygenator, arterial and venous reservoirs, cannulae, an arterial filter, and tubing. The extracorporeal technique currently used in infants and neonates is sometimes associated with neurologic damage. We are developing a modified cardiopulmonary bypass system for neonates that has been tested in vitro and in one animal in vivo. Unlike other extracorporeal circuits which use steady flow, this system utilizes pulsatile flow, a low prime volume (500 ml) and a closed circuit. During in vitro experiments, the pseudo patient's mean arterial pressure was kept constant at 40 mmHg and the extracorporeal circuit pressure did not exceed a mean pressure of 200 mmHg. In our single in vivo experiment, the primary objective was to determine whether physiologic pulsatility with a 10 F (3.3 mm) aortic cannula could be achieved. The results suggest that this is possible.


Asunto(s)
Puente Cardiopulmonar , Flujo Pulsátil/fisiología , Animales , Diseño de Equipo , Circulación Extracorporea/efectos adversos , Humanos , Técnicas In Vitro , Lactante , Recién Nacido , Membranas Artificiales , Consumo de Oxígeno/fisiología , Oxigenadores de Membrana/normas , Cloruro de Polivinilo