Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Monit Comput ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196479

RESUMEN

There is no universally accepted method for positive end expiratory pressure (PEEP) titration approach for patients on spontaneous mechanical ventilation (SMV). Electrical impedance tomography (EIT) guided PEEP-titration has shown promising results in controlled mechanical ventilation (CMV), current implemented algorithm for PEEP titration (based on regional compliance measurements) is not applicable in SMV. Regional peak flow (RPF, defined as the highest inspiratory flow rate based on EIT at a certain PEEP level) is a new method for quantifying regional lung mechanics designed for SMV. The objective is to study whether RPF by EIT is a feasible method for PEEP titration during SMV. Single EIT measurements were performed in COVID-19 ARDS patients on SMV. Clinical (i.e., tidal volume, airway occlusion pressure, end-tidal CO2) and mechanical (cyclic alveolar recruitment, recruitment, cumulative overdistension (OD), cumulative collapse (CL), pendelluft, and PEEP) outcomes were determined by EIT at several pre-defined PEEP thresholds (1-10% CL and the intersection of the OD and CL curves) and outcomes at all thresholds were compared to the outcomes at baseline PEEP. In total, 25 patients were included. No significant and clinically relevant differences were found between thresholds for tidal volume, end-tidal CO2, and P0.1 compared to baseline PEEP; cyclic alveolar recruitment rates changed by -3.9% to -37.9% across thresholds; recruitment rates ranged from - 49.4% to + 79.2%; cumulative overdistension changed from - 75.9% to + 373.4% across thresholds; cumulative collapse changed from 0% to -94.3%; PEEP levels from 10 up to 14 cmH2O were observed across thresholds compared to baseline PEEP of 10 cmH2O. A threshold of approximately 5% cumulative collapse yields the optimum compromise between all clinical and mechanical outcomes. EIT-guided PEEP titration by the RPF approach is feasible and is linked to improved overall lung mechanics) during SMV using a threshold of approximately 5% CL. However, the long-term clinical safety and effect of this approach remain to be determined.

2.
Neth J Med ; 78(4): 167-174, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32641541

RESUMEN

BACKGROUND: Over the last decade, there has been an increasing awareness for the potential harm of the administration of too much oxygen. We aimed to describe self-reported attitudes towards oxygen therapy by clinicians from a large representative sample of intensive care units (ICUs) in the Netherlands. METHODS: In April 2019, 36 ICUs in the Netherlands were approached and asked to send out a questionnaire (59 questions) to their nursing and medical staff (ICU clinicians) eliciting self-reported behaviour and attitudes towards oxygen therapy in general and in specific ICU case scenarios. RESULTS: In total, 1361 ICU clinicians (71% nurses, 24% physicians) from 28 ICUs returned the questionnaire. Of responding ICU clinicians, 64% considered oxygen-induced lung injury to be a major concern. The majority of respondents considered a partial pressure of oxygen (PaO2) of 6-10 kPa (45-75 mmHg) and an arterial saturation (SaO2) of 85-90% as acceptable for 15 minutes, and a PaO2 7-10 kPa (53-75 mmHg) and SaO2 90-95% as acceptable for 24-48 hours in an acute respiratory distress syndrome (ARDS) patient. In most case scenarios, respondents reported not to change the fraction of inspired oxygen (FiO2) if SaO2 was 90-95% or PaO2 was 12 kPa (90 mmHg). CONCLUSION: A representative sample of ICU clinicians from the Netherlands were concerned about oxygen-induced lung injury, and reported that they preferred PaO2 and SaO2 targets in the lower physiological range and would adjust ventilation settings accordingly.


Asunto(s)
Actitud del Personal de Salud , Cuidados Críticos/psicología , Personal de Enfermería en Hospital/psicología , Terapia por Inhalación de Oxígeno/psicología , Médicos/psicología , Adulto , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Países Bajos , Pautas de la Práctica en Medicina , Encuestas y Cuestionarios
3.
BMC Pulm Med ; 15: 107, 2015 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-26420333

RESUMEN

BACKGROUND: Flexible, fibreoptic bronchoscopy (FFB) and bronchoalveolar lavage (BAL) have been used for diagnostic purposes in critically ill ventilated patients. The additional diagnostic value compared to tracheal aspirations in ventilator-associated pneumonia (VAP) has been questioned. Nevertheless, BAL can provide extra information for the differential diagnosis of respiratory disease and good antibiotic stewardship. These benefits should outweigh potential hazards caused by the invasiveness of this diagnostic technique. The focus of the present study was on the clinical course and complications of patients following BAL procedures up to 24 h. METHODS: Hundred sixty-four FFB guided BAL procedures for suspected pneumonia were analysed in an observational study. The clinical course of patients was monitored by respiratory and haemodynamic data before BAL, 1 and 24 h after BAL. Complications were defined and registered. Factors associated with complications were analysed by logistic regression. CLINICAL COURSE: a decrease in average pO2/FiO2 ratio 1 h after BAL from 29 kPa (218 mmHg) to 25 kPa (189 mmHg) (p < 0.05) was observed which fully recovered within 24 h. Respiratory complications: the incidence of procedure related hypo-oxygenation (SaO2 ≤ 88 %) and/or bronchospasm was 9 %; a decrease of >25 % PaO2/FiO2 ratio 1 h after BAL was found in 29 % of patients; no bleeding or pneumothorax were registered. Haemodynamic complications: there were no cases of hypertension and cardiac rhythm disturbances; haemodynamic instability within the first 24 h after BAL was recorded in 22 %; this was correlated with a cardiovascular diagnosis at admission (OR 2.9; 95 % CI 1.2 - 6.7) and the presence of cardiovascular co-morbidity (OR 3.5; 95 % CI 1.5 - 8.3). The incidence of bacteraemia was 7 %. There was no case of procedure related death. DISCUSSION: Frequently occurring haemodynamic and respiratory instability but no cases of cardiac rhythm disturbances, bleeding, pneumothorax or procedure related death were attributable to diagnostic FFB and BAL. The procedures should be conducted under careful supervision by experienced physicians. Only a randomized controlled trial that compares diagnostic FFB and BAL with a non-invasive strategy could ultimately establish the safety profile and clinical utility of these procedures in critically ill ventilated patients.


Asunto(s)
Lavado Broncoalveolar , Broncoscopía , Enfermedad Crítica , Neumonía Asociada al Ventilador/diagnóstico , Complicaciones Posoperatorias/epidemiología , Respiración Artificial , Anciano , Antibacterianos/uso terapéutico , Arritmias Cardíacas/epidemiología , Bacteriemia/epidemiología , Escherichia coli , Infecciones por Escherichia coli/diagnóstico , Infecciones por Escherichia coli/tratamiento farmacológico , Femenino , Hemoptisis/epidemiología , Mortalidad Hospitalaria , Humanos , Hipertensión/epidemiología , Hipoxia/epidemiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Neumonía Estafilocócica/diagnóstico , Neumonía Estafilocócica/tratamiento farmacológico , Neumonía Asociada al Ventilador/tratamiento farmacológico , Neumonía Asociada al Ventilador/microbiología , Neumotórax/epidemiología , Infecciones por Pseudomonas/diagnóstico , Infecciones por Pseudomonas/tratamiento farmacológico , Pseudomonas aeruginosa , Staphylococcus aureus
4.
Respir Med ; 109(11): 1454-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26440675

RESUMEN

BACKGROUND: Exhaled breath analysis is an emerging technology in respiratory disease and infection. Electronic nose devices (e-nose) are small and portable with a potential for point of care application. Ventilator-associated pneumonia (VAP) is a common nosocomial infection occurring in the intensive care unit (ICU). The current best diagnostic approach is based on clinical criteria combined with bronchoalveolar lavage (BAL) and subsequent bacterial culture analysis. BAL is invasive, laborious and time consuming. Exhaled breath analysis by e-nose is non-invasive, easy to perform and could reduce diagnostic time. Aim of this study was to explore whether an e-nose can be used as a non-invasive in vivo diagnostic tool for VAP. METHODS: Seventy-two patients met the clinical diagnostic criteria of VAP and underwent BAL. In thirty-three patients BAL analysis confirmed the diagnosis of VAP [BAL+(VAP+)], in thirty-nine patients the diagnosis was rejected [BAL-]. Before BAL was performed, exhaled breath was sampled from the expiratory limb of the ventilator into sterile Tedlar bags and subsequently analysed by an e-nose with metal oxide sensors (DiagNose, C-it, Zutphen, The Netherlands). From further fifty-three patients without clinical suspicion of VAP or signs of respiratory disease exhaled breath was collected to serve as a control group [control(VAP-]). The e-nose data from exhaled breath were analysed using logistic regression. RESULTS: The ROC curve comparing [BAL+(VAP+)] and [control(VAP-)] patients had an area under the curve (AUC) of 0.82 (95% CI 0.73-0.9). The sensitivity was 88% with a specificity of 66%. The comparison of [BAL+(VAP+)] and [BAL-] patients revealed an AUC of 0.69; 95% CI 0.57-0.81) with a sensitivity of 76% with a specificity of 56%. CONCLUSION: E-nose lacked sensitivity and specificity in the diagnosis of VAP in the present study for current clinical application. Further investigation into this field is warranted to explore the diagnostic possibilities of this promising new technique.


Asunto(s)
Pruebas Respiratorias/instrumentación , Nariz Electrónica , Neumonía Bacteriana/diagnóstico , Neumonía Asociada al Ventilador/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Bacterias/aislamiento & purificación , Pruebas Respiratorias/métodos , Lavado Broncoalveolar/métodos , Líquido del Lavado Bronquioalveolar/microbiología , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Adulto Joven
6.
J Med Virol ; 85(10): 1836-41, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23861144

RESUMEN

Acanthamoeba polyphaga mimivirus (APMV) belongs to the amoebae-associated microorganisms. Antibodies to APMV have been found in patients with pneumonia suggesting a potential role as a respiratory pathogen. In addition, positive serology for APMV was associated with an increased duration of mechanical ventilation and intensive care unit stay in patients with ventilator-associated pneumonia. The aim of the present study was to assess the presence of APMV in bronchoalveolar lavage fluid samples of critically ill patients suspected of ventilator-associated pneumonia. The study was conducted in the intensive care unit of the Maastricht University Medical Centre. All consecutive bronchoalveolar lavage fluid samples obtained between January 2005 and October 2009 from patients suspected of ventilator-associated pneumonia were eligible for inclusion. All samples were analyzed by real-time PCR targeting the APMV. A total of 260 bronchoalveolar lavage fluid samples from 214 patients (139 male, 75 female) were included. Bacterial ventilator-associated pneumonia was confirmed microbiologically in 105 out of 260 (40%) suspected episodes of ventilator-associated pneumonia (86 patients). The presence of APMV DNA could not be demonstrated in the bacterial ventilator-associated pneumonia positive or in the bacterial ventilator-associated pneumonia negative bronchoalveolar lavage fluid samples. Although suspected, APMV appeared not to be present in critically ill patients suspected of ventilator-associated pneumonia, and APMV does not seem to be a frequent cause of ventilator-associated pneumonia.


Asunto(s)
Infecciones por Virus ADN/epidemiología , Infecciones por Virus ADN/virología , Mimiviridae/aislamiento & purificación , Neumonía Asociada al Ventilador/epidemiología , Neumonía Asociada al Ventilador/virología , Centros Médicos Académicos , Adulto , Anciano , Anciano de 80 o más Años , Líquido del Lavado Bronquioalveolar/virología , Enfermedad Crítica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA