Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39238168

RESUMEN

BACKGROUND: Complications associated with cardiovascular implantable electronic devices may necessitate device and lead removal. An open approach to removal may be electively chosen in cases with high risk of complications or those requiring additional concomitant cardiac surgery. This study aimed to investigate outcomes of patients who underwent elective open lead extractions (OLE) at two large tertiary care centers. METHODS: The records of 29 patients undergoing elective OLE were analyzed through retrospective chart review. RESULTS: 69 total leads were extracted from 29 patients (77% completely, 23% partially). The average age of the oldest leads was 13.3 ± 11.3 years. Infective endocarditis with severe valvular insufficiency requiring valvular intervention (41%)-an infectious etiology, and tricuspid valve intervention to correct RV lead-related severe TR (38%)-a noninfectious etiology, were the most common reasons for OLE. 38% of the patients had additional co-primary or secondary indications for open extraction, such as CABG and pericardiectomies. The rate of major complications and procedural failure was 3% each (1/29). 30-day survival was 100%, and 1-year survival was 92%. The average length of hospital stay was 15 days and higher among those undergoing OLE for infectious indications. CONCLUSION: Open lead extractions offered a similar clinical success rate (97%) to transvenous extractions in this cohort and may be a viable alternative for those necessitating valvular intervention or when the risk of complications from TLE is considered very high.

2.
Circulation ; 2024 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-39327797

RESUMEN

BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter-defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous ICDs and effective antitachycardia pacing (ATP), while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. We aim to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, pre-market clinical study. Individuals with a class I or IIa indication for a single-chamber ICD per guidelines were enrolled. Freedom from major system- or procedure-related complications, as well as appropriate and inappropriate therapy rates, were assessed through 3 years using the Kaplan-Meier method. Anti-tachycardia pacing success was calculated using simple proportions. RESULTS: An implant was attempted in 316 patients [25.3% female, 53.8±13.1 years old, 81.6% primary prevention, LVEF 38.9%±15.4%]. Of 299 patients with a successful implant, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with either ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier-estimated rate of first any appropriate therapy of 9.2% at 3 years. Antitachycardia pacing was successful in 77.1% (37/48) of episodes, and ATP usage significantly increased from discharge to last follow-up visit (P<0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implant to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile.

3.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39210643

RESUMEN

AIMS: The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. METHODS AND RESULTS: This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2-58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate <1 year and 80% (8/10) success rate >1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. CONCLUSION: Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Humanos , Remoción de Dispositivos/métodos , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Anciano , Adulto , Resultado del Tratamiento , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Proyectos Piloto , Factores de Tiempo , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos
5.
Artículo en Inglés | MEDLINE | ID: mdl-38967391

RESUMEN

BACKGROUND: The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject. OBJECTIVE: To identify CT characteristics associated with increased TLE difficulty. METHODS: All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty. RESULTS: A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively. CONCLUSION: In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.

6.
JACC Adv ; 3(2): 100773, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38939375

RESUMEN

Background: Cardiac implantable electronic devices (CIEDs) infection remains a serious complication, causing increased morbidity and mortality. Early recognition and escalation to definitive therapy including extraction of the infected device often pose challenges. Objectives: The purpose of this study was to assess U.S.-based physicians current practices in diagnosing and managing CIED infections and explore potential extraction barriers. Methods: An observational survey was performed by the American College of Cardiology including U.S. physicians managing CIEDs from February to March 2022. Sampling techniques and screener questions determined eligibility. The survey featured questions on knowledge and experience with CIED infection patients and case scenarios. Results: Of 387 physicians completing the survey (20% response rate), 49% indicated familiarity with current guidelines regarding CIED infection. Electrophysiologists (EPs) (91%) were more familiar with these guidelines, compared to non-EP cardiologists (29%) and primary care physicians (23%). Only 30% of physicians specified that their institution had guideline-based protocols in place for managing patients with CIED infection. When presented with pocket infection cases, approximately 89% of EPs and 50% of non-EP cardiologists would follow guideline recommendation to do complete CIED system removal, while 70% of primary care physicians did not recommend guideline-directed treatment. Conclusions: There are gaps in familiarity of guidelines as well as the knowledge in practical management of CIED infection with non-extracting physicians. Most institutions lack a definite pathway. Addressing discrepancies, including guideline education and streamlining care or referral pathways, will be a key factor to bridging the gap and improving CIED infection patient outcomes.

7.
Heart Rhythm O2 ; 5(5): 289-293, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840769

RESUMEN

Background: Cardiovascular implantable electronic device (CIED) infections are a common indication for device extraction. Early diagnosis and complete system removal are crucial to reduce morbidity and mortality. The lack of clear infectious symptoms makes the diagnosis of pocket infections challenging and may delay referral for extraction. Objective: We aimed to determine if inflammatory biomarkers can help diagnose CIED isolated pocket infection. Methods: We performed a retrospective analysis of all patients undergoing transvenous lead extraction for CIED infection at the University of California San Diego from 2012 to 2022 (N = 156). Patients were classified as systemic infection (n = 88) or isolated pocket infection (n = 68). Prospectively collected preoperative procalcitonin (PCT), C-reactive protein, and white blood cell count were compared between groups. Results: Pairwise comparisons revealed that the systemic infection group had a higher PCT than the control group (P < .001) and the pocket infection group (P = .009). However, there was no significant difference in PCT value between control subjects and isolated pocket infection subjects. Higher white blood cell count was only associated with systemic infection when compared with our control group (P = .018). Conclusion: In patients diagnosed with CIED infections requiring extraction, inflammatory biomarkers were not elevated in isolated pocket infection. Inflammatory markers are not predictive of the diagnosis of pocket infections, which ultimately requires a high level of clinical suspicion.

8.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749633

RESUMEN

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Marcapaso Artificial/efectos adversos , Masculino , Ecocardiografía Transesofágica , Tomografía Computarizada por Rayos X , Anciano , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/diagnóstico por imagen , Femenino , Persona de Mediana Edad
9.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
10.
Clin Infect Dis ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466039

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

11.
Heart Rhythm ; 21(5): e1-e29, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38466251

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Consenso , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Humanos , Infecciones Cardiovasculares/diagnóstico , Endocarditis/diagnóstico , Endocarditis/diagnóstico por imagen , Fluorodesoxiglucosa F18/farmacología , Leucocitos , Imagen Multimodal/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacología , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Sociedades Médicas , Estados Unidos
12.
JACC Cardiovasc Imaging ; 17(6): 669-701, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38466252

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multisocietal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multifocal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Consenso , Técnica Delphi , Fluorodesoxiglucosa F18 , Leucocitos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Radiofármacos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Fluorodesoxiglucosa F18/administración & dosificación , Radiofármacos/administración & dosificación , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Pronóstico , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Reproducibilidad de los Resultados , Endocarditis/diagnóstico por imagen , Infecciones Cardiovasculares/diagnóstico por imagen , Algoritmos
13.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38472038

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Infecciones Cardiovasculares , Endocarditis , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Consenso , Tomografía Computarizada por Rayos X , Imagen Multimodal , Endocarditis/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único
15.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38545321

RESUMEN

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

19.
J Interv Card Electrophysiol ; 67(3): 639-648, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37855992

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Venas Pulmonares/cirugía
20.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38047465

RESUMEN

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Asunto(s)
Desfibriladores Implantables , Humanos , Calidad de Vida , Estudios Prospectivos , Encuestas y Cuestionarios , Medición de Resultados Informados por el Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA