Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Can J Cardiol ; 40(1): 113-122, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37726077

RESUMEN

BACKGROUND: Data on the long-term impact of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement (TAVR) remain sparse. We therefore aimed to investigate the incidence, predictive factors, and long-term prognostic impact of PPM on bioprosthesis durability and mortality. METHODS: This was a single-centre retrospective study including 2117 patients who underwent TAVR for aortic stenosis from 2002 to 2022. Moderate PPM was defined by indexed effective orifice area (iEOA) > 0.65 and ≤ 0.85 cm2/m2 (> 0.55 and ≤ 0.70 cm2/m2 if BMI ≥ 30 kg/m2) and severe PPM by an iEOA ≤ 0.65 cm2/m2 (≤ 0.55 cm2/m2 If BMI ≥ 30 kg/m2). RESULTS: There were 351 patients (16.6%) with PPM, including 39 patients (1.8%) with severe PPM and 312 patients (14.7%) with moderate PPM. The mean follow-up duration was 31.2 ± 26.5 months. Factors independently associated with the occurrence of PPM were body surface area (odds ratio [OR] 3.32, 95% confidence interval [CI] 1.32-8.35; P = 0.01), valve-in-valve TAVR (OR 6.12, 95% CI 2.29-16.08; P < 0.001), small annulus (OR 2.42, 95% CI 1.41-4.07; P = 0.001), and the use of a balloon-expandable valve (OR 4.17, 95% CI 2.17-8.33; P < 0.001). PPM was associated with increased risk of mortality (hazard ratio [HR] 1.3, 95% CI 1.1-1.5, P = 0.004) and valve thrombosis (HR 4.2, 95% CI 1.4-12.6, P = 0.01), and a trend towards increased risk of structural valve deterioration (HR 1.7, 95% CI 0.9-2.9; P = 0.08). CONCLUSIONS: The results of this study suggest that PPM has a negative long-term impact on outcomes after TAVR. These findings emphasise the importance of preventing PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Diseño de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Factores de Riesgo
2.
Arch Cardiovasc Dis ; 115(4): 196-205, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35559901

RESUMEN

BACKGROUND: Since the first-in-man implantation of a transcatheter aortic stented valve in April 2002 in Rouen, the procedure has expanded worldwide. In our centre, all transfemoral procedures have been performed using local anaesthesia without transoesophageal echocardiographic monitoring. AIM: To report our experience of transfemoral arterial transcatheter aortic valve implantation (TAVI) over the last 2 decades, following the evolution of devices, practices and indications. METHODS: Between 2002 and 2021, 2097 consecutive patients had a TAVI procedure in our centre. Among them, 1780 underwent transfemoral arterial aortic valve implantation, and were subdivided into three groups according to the time period: before 2009; 2009-2014; and 2014-2021. RESULTS: Median age was 85 years, and remained unchanged over time. The mean logistic EuroSCORE gradually decreased over time (28% before 2009 vs 15% for 2009-2014 vs 11% since 2014; P<0.001). Predilatation was performed almost systematically before 2009 (93%), but was rarely performed in the last period (14%; P<0.001). Thirty-day all-cause mortality decreased over time, and was only 1.4% in 2021. Length of stay decreased considerably, with a median duration of only 2 days after the procedure, and>70% of patients were discharged home within 72hours. Similarly, procedural duration, X-ray time and contrast volume decreased over time. CONCLUSION: Transfemoral aortic valve implantation, performed as a minimalist "stent-like" procedure using only local anaesthesia, is feasible in the vast majority of patients, with excellent outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
3.
ESC Heart Fail ; 9(1): 782-785, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34766440

RESUMEN

We report the case of a 58-year-old female with severe postcapillary pulmonary hypertension (averaged mean pulmonary arterial pressure was 49 mmHg, pulmonary arterial wedge pressure 29 mmHg, and right atrial pressure 8 mmHg) due to heart failure with preserved ejection fraction. A left-to-right atrial shunt was created using an 8 mm cutting balloon, under transesophageal echocardiography guidance. Both pulmonary arterial and wedge pressure dramatically decreased after the procedure. Symptoms immediately improved and benefits were sustained at 6 months of follow-up. This case suggests that iatrogenic septal defect using a cutting balloon could be an option to treat symptomatic postcapillary pulmonary hypertension.


Asunto(s)
Apéndice Atrial , Hipertensión Pulmonar , Ecocardiografía Transesofágica , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/terapia , Persona de Mediana Edad , Presión Esfenoidal Pulmonar
4.
Am J Cardiol ; 145: 119-127, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33460601

RESUMEN

Vascular complications (VCs) are difficult to predict and remain an important issue after transfemoral (TF) transcatheter aortic valve implantation (TAVI) although their incidence has decreased with size reduction of introducers. We aimed to evaluate a standardized measurement of femoral artery depth (FAD) using computed tomography (CT) to predict VCs after TAVI. We performed a retrospective study of 679 TF TAVI patients. We evaluated a standardized CT method to measure FAD immediately above the bifurcation. Sheath-to-femoral-artery ratio (SFAR), calcification, and tortuosity were also evaluated. VCs were defined by the Valve Academic Research Consortium (VARC)-2. Receiver operating characteristic (ROC) curves were used to predict major VCs and the need for a stent-graft. The median values of FAD and SFAR were 49.0 (36.2 to 66.7) mm and 0.95 (0.81 to 1.18), respectively. Major VCs occurred in 37 (5.4%) patients and a stent-graft was required in 49 (7.1%) patients. FAD predicted the need for a stent-graft [0.61 (0.51 to 0.70), p = 0.04] but not major VCs [0.52 (0.40 to 0.63), p = 0.76]. In contrast, SFAR did not predict the need for a stent-graft [0.53 (0.43 to 0.62), p = 0.61] but predicted major VCs [0.70 (0.58 to 0.81), p = 0.001]. Calcification and tortuosity predicted neither major VCs nor the need for a stent-graft. In conclusion, the results of our study suggest that CT measurements of FAD and SFAR provide additional information to predict major VCs and the need for a femoral stent-graft after TF TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Calcificación Vascular/diagnóstico por imagen , Enfermedades Vasculares/epidemiología , Lesiones del Sistema Vascular/epidemiología , Anciano , Anciano de 80 o más Años , Catéteres Cardíacos , Femenino , Arteria Femoral/patología , Humanos , Masculino , Tomografía Computarizada Multidetector , Obesidad/epidemiología , Tamaño de los Órganos , Factores de Riesgo , Stents , Reemplazo de la Válvula Aórtica Transcatéter , Calcificación Vascular/epidemiología , Enfermedades Vasculares/cirugía , Injerto Vascular , Lesiones del Sistema Vascular/cirugía
5.
Clin Res Cardiol ; 110(1): 40-49, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32335689

RESUMEN

BACKGROUND: Currently, there are no recommendations regarding the minimum duration of in-hospital monitoring after transfemoral (TF) transcatheter aortic valve replacement (TAVR) and practices are extremely heterogeneous. We, therefore, aimed to evaluate length of stay (LOS) and predictive factors for late discharge after TF TAVR using data from the FRANCE TAVI registry. METHODS: TAVR was performed in 12,804 patients in 48 French centers between 2013 and 2015. LOS was evaluated in 5857 TF patients discharged home. LOS was calculated from TAVR procedure (day 0) to discharge. The study population was divided into three groups based on LOS values. Patients discharged within 3 days constituted the "very early" discharge group, patients with a LOS between 3 and 6 days constituted the "early" discharge group, and patients with a length of stay > 6 days constituted the "late" discharge group. RESULTS: The median LOS was 7 (5-9) days and was extremely variable among centers. The proportion of patients discharged very early, early, and late was 4.4% (n = 256), 33.7% (n = 1997), and 61.9% (n = 3624) respectively. Variables associated with late discharge were female sex, co-morbidities, major complications, self-expandable valve, general anesthesia, and a significant center effect. In contrast, history of previous pacemaker was a protective factor. The composite of death and re-admission in the very early and early versus late discharge groups was similar at 30 days (3.3% vs. 3.5%, p = 0.66). CONCLUSIONS: LOS is extremely variable after TF TAVR in France. Co-morbidities and complications were predictive factors of late discharge after TAVI. Interestingly, the use of self-expandable prosthesis and general anesthesia may also contribute to late discharge. Our results confirm that early discharge is safe.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tiempo de Internación/tendencias , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Cateterismo Periférico/métodos , Femenino , Arteria Femoral , Estudios de Seguimiento , Humanos , Masculino , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
EuroIntervention ; 14(3): e264-e271, 2018 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-29599103

RESUMEN

AIMS: Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. METHODS AND RESULTS: All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. CONCLUSIONS: Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Consenso , Humanos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
7.
JACC Cardiovasc Interv ; 10(23): 2426-2436, 2017 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-29217006

RESUMEN

OBJECTIVES: The aim of this study was to assess the incidence, prognostic impact, and predictive factors of readmission for congestive heart failure (CHF) in patients with severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR is indicated in patients with severe symptomatic aortic stenosis in whom surgery is considered high risk or is contraindicated. Readmission for CHF after TAVR remains a challenge, and data on prognostic and predictive factors are lacking. METHODS: All patients who underwent TAVR from January 2010 to December 2014 were included. Follow-up was achieved for at least 1 year and included clinical and echocardiographic data. Readmission for CHF was analyzed retrospectively. RESULTS: This study included 546 patients, 534 (97.8%) of whom were implanted with balloon-expandable valves preferentially via the transfemoral approach in 87.8% of cases. After 1 year, 285 patients (52.2%) had been readmitted at least once, 132 (24.1%) for CHF. Patients readmitted for CHF had an increased risk for death (p < 0.0001) and cardiac death (p < 0.0001) compared with those not readmitted for CHF. On multivariate analysis, aortic mean gradient (hazard ratio [HR]: 0.88; 95% confidence interval [CI]: 0.79 to 0.99; p = 0.03), post-procedural blood transfusion (HR: 2.27; 95% CI: 1.13 to 5.56; p = 0.009), severe post-procedural pulmonary hypertension (HR: 1.04; 95% CI: 1.00 to 1.07; p < 0.0001), and left atrial diameter (HR: 1.47; 95% CI: 1.08 to 2.01; p = 0.02) were independently associated with CHF readmission at 1 year. CONCLUSIONS: Readmission for CHF after TAVR was frequent and was strongly associated with 1-year mortality. Low gradient, persistent pulmonary hypertension, left atrial dilatation, and transfusions were predictive of readmission for CHF.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Insuficiencia Cardíaca/epidemiología , Readmisión del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Causas de Muerte , Distribución de Chi-Cuadrado , Ecocardiografía , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/fisiopatología , Incidencia , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
Presse Med ; 45(10): 898-902, 2016 Oct.
Artículo en Francés | MEDLINE | ID: mdl-27374262

RESUMEN

Balloon aortic valvuloplasty is a relatively simple procedure with a low rate of complications despite patients' frailty. Urgent balloon aortic valvuloplasty is especially useful in patients with temporary contra-indication to TAVI or in case of difficult clinical scenario. It allows for a functional improvement for up to 6 months. This period should be used to bridge the patient to TAVI or surgical aortic valve replacement, stand-alone aortic valvuloplasty being without mid-term survival benefit.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Valvuloplastia con Balón , Tratamiento de Urgencia , Valvuloplastia con Balón/métodos , Humanos , Selección de Paciente , Resultado del Tratamiento
9.
Circ Heart Fail ; 9(4): e002895, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27059805

RESUMEN

BACKGROUND: Chronic heart failure (CHF) induces endothelial dysfunction in part because of decreased nitric oxide (NO(·)) production, but the direct link between endothelial dysfunction and aggravation of CHF is not directly established. We previously reported that increased NO production via inhibition of protein tyrosine phosphatase 1B (PTP1B) is associated with reduced cardiac dysfunction in CHF. Investigation of the role of endothelial PTP1B in these effects may provide direct evidence of the link between endothelial dysfunction and CHF. METHODS AND RESULTS: Endothelial deletion of PTP1B was obtained by crossing LoxP-PTP1B with Tie2-Cre mice. CHF was assessed 4 months after myocardial infarction. In some experiments, to exclude gene extinction in hematopoietic cells, Tie2-Cre/LoxP-PTP1B mice were lethally irradiated and reconstituted with bone marrow from wild-type mice, to obtain mouse with endothelial-specific deletion of PTP1B. Vascular function evaluated ex vivo in mesenteric arteries showed that in wild-type mice, CHF markedly impaired NO-dependent flow-mediated dilatation. CHF-induced endothelial dysfunction was less marked in endoPTP1B(-/-) mice, suggesting restored NO production. Echocardiographic, hemodynamic, and histological evaluations demonstrated that the selectively improved endothelial function was associated with reduced left ventricular dysfunction and remodeling, as well as increased survival, in the absence of signs of stimulated angiogenesis or increased cardiac perfusion. CONCLUSIONS: Prevention of endothelial dysfunction, by endothelial PTP1B deficiency, is sufficient to reduce cardiac dysfunction post myocardial infarction. Our results provide for the first time a direct demonstration that endothelial protection per se reduces CHF and further suggest a causal role for endothelial dysfunction in CHF development.


Asunto(s)
Endotelio Vascular/enzimología , Insuficiencia Cardíaca/prevención & control , Arterias Mesentéricas/enzimología , Proteína Tirosina Fosfatasa no Receptora Tipo 1/metabolismo , Vasodilatación , Disfunción Ventricular Izquierda/prevención & control , Animales , Trasplante de Médula Ósea , Enfermedad Crónica , Modelos Animales de Enfermedad , Endotelio Vascular/fisiopatología , Insuficiencia Cardíaca/enzimología , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/fisiopatología , Arterias Mesentéricas/fisiopatología , Ratones Endogámicos C57BL , Ratones Noqueados , Infarto del Miocardio/enzimología , Infarto del Miocardio/genética , Infarto del Miocardio/fisiopatología , Óxido Nítrico/metabolismo , Proteína Tirosina Fosfatasa no Receptora Tipo 1/deficiencia , Proteína Tirosina Fosfatasa no Receptora Tipo 1/genética , Transducción de Señal , Factores de Tiempo , Disfunción Ventricular Izquierda/enzimología , Disfunción Ventricular Izquierda/genética , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Remodelación Ventricular
10.
Am J Cardiol ; 115(8): 1116-22, 2015 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-25726383

RESUMEN

There is currently no consensus on the duration of hospitalization required after transfemoral transcatheter aortic valve implantation (TAVI). We report the feasibility and safety of early discharge after TAVI with the Edwards SAPIEN-XT prosthesis. From 2009 to 2013, 337 patients underwent transfemoral TAVI with the Edwards SAPIEN-XT prosthesis using local anesthesia and were discharged home either early (≤3 days, Early Discharge group, n = 121) or after 3 days (Late Discharge group, n = 216). The primary end point of the study combined death and rehospitalization from discharge to 30-day follow-up. Patients in the Early Discharge group were less symptomatic (New York Heart Association class ≥III: 64.5% vs 75.5%, p = 0.01) and had less renal failure (creatinine: 102.1 ± 41.0 vs 113.3 ± 58.9 µmol/L, p = 0.04), atrial fibrillation (33.1% vs 46.3%, p = 0.02), and previous balloon aortic valvuloplasty (11.6% vs 23.1%, p = 0.01) and were more likely to have a pacemaker before TAVI (16.5% vs 8.3%, p = 0.02). Pre-existing pacemaker (p = 0.05) and the absence of acute kidney injury (p = 0.02) were independent predictors of an early discharge, whereas previous balloon aortic valvuloplasty (p = 0.03) and post-TAVI blood transfusions (p = 0.002) were independent predictors of late discharge. The primary end point occurred in 4 patients (3.3%) in the Early Discharge group and in 11 patients (5.1%) in the Late Discharge group (p = 0.58). In conclusion, the results of our study suggest that early discharge after transfemoral TAVI using the Edwards SAPIEN-XT prosthesis is feasible and safe in selected patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Prótesis Valvulares Cardíacas , Alta del Paciente/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía , Electrocardiografía , Estudios de Factibilidad , Femenino , Arteria Femoral , Estudios de Seguimiento , Humanos , Tiempo de Internación/tendencias , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
11.
J Invasive Cardiol ; 26(8): E115-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25091105

RESUMEN

Chronic coronary total occlusion (CTO) is still one of the last frontiers for myocardial revascularization by percutaneous coronary interventions (PCI). New devices (microcatheters, dedicated tools, guidewires), new techniques, and retrograde approach increase success rate of CTOPCI. The reverse controlled anterograde and retrograde subintimal tracking (CART) technique can be an option to succeed. Sometimes the retrograde guidewire fails to cross the calcified proximal cap into the antegrade space, despite several standard balloon inflations. In our case, we describe the first case of CTO-PCI by the reverse CART technique using a cutting balloon to facilitate the retrograde connection with the antegrade space in case of failure with conventional balloon.


Asunto(s)
Enfermedad de la Arteria Coronaria/complicaciones , Oclusión Coronaria , Cuidados Intraoperatorios/métodos , Intervención Coronaria Percutánea , Anciano , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/etiología , Oclusión Coronaria/fisiopatología , Oclusión Coronaria/cirugía , Humanos , Masculino , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Equipo Quirúrgico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
12.
Tex Heart Inst J ; 39(5): 731-5, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23109781

RESUMEN

Papillary fibroelastoma is a rare, benign cardiac tumor typically found on the heart valves. It is usually discovered incidentally on echocardiography. The clinical presentation of cardiac papillary fibroelastoma varies from no symptoms to severe embolic sequelae. We report the incidental finding of papillary fibroelastoma in 2 patients. In each, we chose to excise the tumor. The relevant medical literature provides little guidance regarding whether to excise a small papillary fibroelastoma in an asymptomatic patient. Multimodal imaging, which we discuss in the context of our patients' cases, aids the cardiologist and cardiovascular surgeon in more accurately evaluating papillary fibroelastoma preoperatively.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Diagnóstico por Imagen , Fibroma/diagnóstico , Fibroma/cirugía , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirugía , Hallazgos Incidentales , Diagnóstico por Imagen/métodos , Ecocardiografía Transesofágica , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA