Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 26(2): 101056, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38971502

RESUMEN

BACKGROUND: The presence of mitral annulus disjunction (MAD) has been considered a high-risk feature for sudden cardiac death based on selected study populations. We aimed to assess the prevalence of MAD in consecutive patients undergoing clinically indicated cardiovascular magnetic resonance (CMR), its association with ventricular arrhythmias, mitral valve prolapse (MVP), and other CMR features. METHODS: This single-center retrospective study included consecutive patients referred to CMR at our institution between June 2021 and November 2021. MAD was defined as a ≥1 mm displacement between the left atrial wall-mitral valve leaflet junction and the left ventricular wall during end-systole. MAD extent was defined as the maximum longitudinal displacement. Associates of MAD were evaluated at univariable and multivariable regression analysis. The study endpoint, a composite of (aborted) sudden cardiac death, unexplained syncope, and sustained ventricular tachycardia, was evaluated at a 12-month follow-up. RESULTS: Four hundred and forty-one patients 55 ± 18 years, 267/441 (61%) males) were included, and 29/441 (7%) had MVP. The prevalence of MAD ≥1 mm, 4 mm, and 6 mm was 214/441 (49%), 63/441 (14%), and 15/441 (3%), respectively. Patients with MVP showed a higher prevalence of MAD greater than 1 mm (26/29 (90%) vs 118/412 (46%)); p < 0.001), 4 mm (14/29 (48%) vs 49/412 (12%)); p < 0.001), and 6 mm (3/29 (10%) vs 12/412 (3%)); p = 0.03), and a greater MAD extent (4.2 mm, 3.0-5.7 mm vs 2.8 mm, 1.9-4.0 mm; p < 0.001) compared to patients without MVP. MVP was the only morpho-functional abnormality associated with MAD at multivariable analysis (p < 0.001). A high burden of ventricular ectopic beats at baseline Holter-electrocardiogram was associated with MAD ≥4 mm and MAD extent (p < 0.05). The presence of MAD ≥1 mm (0.9% vs 1.8%; p = 0.46), MAD ≥4 mm (1.6% vs 1.3%; p = 0.87), or MVP (3.5% vs 1.2%; p = 0.32) were not associated with the study endpoint, whereas patients with MAD ≥6 mm showed a trend toward a higher likelihood of the study endpoint (6.7% vs 1.2%; p = 0.07). CONCLUSION: MAD of limited severity was common in consecutive patients undergoing CMR. Patients with MVP showed higher prevalence and greater extent of MAD. Extended MAD was rarer and showed association with ventricular arrhythmias at baseline. The mid-term prognosis of MAD seems benign; however, prospective studies are warranted to search for potential "malignant MAD extents" to improve patients' risk stratification.

2.
Am Heart J ; 275: 128-137, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

4.
JACC Case Rep ; 29(3): 102191, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361557

RESUMEN

An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed.

6.
Artículo en Inglés | MEDLINE | ID: mdl-37931791

RESUMEN

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

7.
J Cardiovasc Echogr ; 33(1): 1-9, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37426716

RESUMEN

Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography.

8.
J Cardiovasc Dev Dis ; 10(6)2023 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-37367391

RESUMEN

Cardiac magnetic resonance (CMR) has been recently implemented in clinical practice to refine the daunting task of establishing the risk of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). We present an exemplificative case highlighting the practical clinical utility of this imaging modality in a 24-year-old man newly diagnosed with an apical HCM. CMR was essential in unmasking a high risk of SCD, which appeared low-intermediate after traditional risk assessment. A discussion examines the essential role of CMR in guiding the patient's therapy and underlines the added value of CMR, including novel and potential CMR parameters, compared to traditional imaging assessment for SCD risk stratification.

10.
Echocardiography ; 40(6): 464-474, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37100745

RESUMEN

BACKGROUND: Cardiovascular sequelae may occur in patients recovered from coronavirus disease 2019 (COVID-19). Recent studies have detected a considerable incidence of subclinical myocardial dysfunction-assessed with speckle-tracking echocardiography-and of long-COVID symptoms in these patients. This study aimed to define the long-term prognostic role of subclinical myocardial dysfunction and long-COVID condition in patients recovered from COVID-19 pneumonia. METHODS: We prospectively followed up 110 patients hospitalized at our institution due to COVID-19 pneumonia in April 2020 and then recovered from SARS-CoV-2 infection. A 7-month clinical and echocardiographic evaluation was performed, followed by a 21-month clinical follow-up. The primary outcome was major adverse cardiovascular events (MACE), a composite of myocardial infarction, stroke, heart failure hospitalization, and all-cause mortality. RESULTS: A subclinical myocardial dysfunction-defined as an impairment of left ventricular global longitudinal strain (≥-18%)-was identified at a 7-month follow-up in 37 patients (34%), was associated with an increased risk of long-term MACE with a good discriminative power (area under the curve: .73) and resulted in a strong independent predictor of extended MACE in multivariate regression analyses. Long-COVID condition was not associated with a worse long-term prognosis, instead. CONCLUSIONS: In patients recovered from COVID-19 pneumonia, a subclinical myocardial dysfunction is present in one-third of the whole population at 7-month follow-up and is associated with a higher risk of MACE at long-term follow-up. Speckle-tracking echocardiography is a promising tool to optimize the risk-stratification in patients recovered from COVID-19 pneumonia, while the definition of a long-COVID condition has no prognostic relevance.


Asunto(s)
COVID-19 , Disfunción Ventricular Izquierda , Humanos , Factores de Riesgo , Síndrome Post Agudo de COVID-19 , COVID-19/complicaciones , Valor Predictivo de las Pruebas , SARS-CoV-2 , Pronóstico , Disfunción Ventricular Izquierda/complicaciones
11.
Pacing Clin Electrophysiol ; 46(5): 395-408, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36949598

RESUMEN

BACKGROUND: Heart failure (HF) and atrial arrhythmias (AAs) are two clinical conditions that characterize the daily clinical practice of cardiologists. In this perspective review, we analyze the shared etiopathogenetic pathways of atrial arrhythmias, which are the most common cause of atrial arrhythmias-induced cardiomyopathy (AACM) and HF. HYPOTHESIS: The aim is to explore the pathophysiology of these two conditions considering them as a "unicum", allowing the definition of a cardiovascular continuum where it is possible to predict the factors and to identify the patient phenotype most at risk to develop HF due to atrial arrhythmias. METHODS: Potentially eligible articles, identified from the Electronic database (PubMed), and related references were used for a literature search that was conducted between January 2022 and January 2023. Search strategies were designed to identify articles that reported atrial arrhythmias in association with heart failure and vice versa. For the search we used the following keywords: atrial arrhythmias, atrial fibrillation, heart failure, arrhythmia-induced cardiomyopathy, tachycardiomyopathy. We identified 620 articles through the electronic database search. Out of the 620 total articles we removed 320 duplicates, thus selecting 300 eligible articles. About 150 titles/abstracts were excluded for the following reasons: no original available data, no mention of atrial arrhythmias and heart failure crosstalk, very low quality analysis or evidence. We excluded also non-English articles. When multiple articles were published on the same topic, the articles with the most complete set of data were considered. We preferentially included all papers that could provide the best evidence in the field. As a result, the present review article is based on a final number of 104 references. RESULTS: While the pathophysiology of AACM and Heart Failure with reduced ejection fraction (HFrEF) has been studied in detail over the years, the causal link between atrial arrhythmias and heart failure with Preserved Ejection Fraction (HFpEF) has been often subject of interest. HFpEF is strictly related to AAs, which has always been considered significant risk factor. In this review we described the pathophysiological links between atrial fibrillation and heart failure. Furthermore, we illustrated and discussed the preclinical and clinical predicting factors of AF and HFpEF, and the corresponding targets of the available therapeutic agents. Finally, we outlined the patient phenotype at risk of developing AF and HFpEF (Central Illustration). CONCLUSIONS: In this review, we underline how these two clinical conditions (AF and HFpEF) represent a "unicum" and, therefore, should be considered as a single disease that can manifest itself in the same phenotype of patients but at different times. Furthermore, considering that today we have few therapeutic strategies to treat these patients, it would be good to make an early diagnosis in the initial stages of the disease or intervene even before the development of signs and symptoms of HF. This is possible only by paying greater attention to patients with predisposing factors and carrying out a targeted screening with the correct diagnostic methods. A systemic approach aimed at improving the immuno-metabolic profile of these patients by lowering the body mass index, threatening the predisposing factors, lowering the mean heart rate and reducing the sympathetic nervous system activation is the key strategy to reduce the clinical impact of this disease.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Volumen Sistólico/fisiología , Factores de Riesgo , Pronóstico
12.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36752044

RESUMEN

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
13.
J Cardiovasc Echogr ; 33(3): 125-132, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38161775

RESUMEN

Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and ≥40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers.

14.
Catheter Cardiovasc Interv ; 100(4): 620-627, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35842775

RESUMEN

OBJECTIVES: To assess feasibility and safety of second-generation left atrial appendage closure (LAAC) Ultraseal device in patients with nonvalvular atrial fibrillation (NVAF). BACKGROUND: LAAC with first-generation Ultraseal device (Cardia, Eagan, Minnesota) has been shown to be a feasible therapeutic option in patients with NVAF. However, there is a paucity of data regarding the novel second-generation Ultraseal device. METHODS: All patients with NVAF undergoing second-generation Ultraseal device implantation between February 2018 and September 2020 were included in a multicenter international registry. Periprocedural and post-discharge events were collected through 6-month follow-up. Co-primary efficacy endpoints were device success and technical success while primary safety endpoint was in-hospital major adverse event (MAE) occurrence. RESULTS: A total of 52 patients were included: mean age 75 ± 8, 30.8% women, mean HAS-BLED 3 ± 1. The device was successfully implanted in all patients. Technical success was achieved in 50 patients (96.1%). In-hospital MAEs occurred in three patients (5.8%). The incidence of 6-month all-cause death and major bleeding was 11.6% and 2.1%, respectively. No strokes, transient ischemic attacks, systemic embolisms, or device embolization were reported after discharge. CONCLUSIONS: Second-generation Ultraseal device implantation was associated with high success rates and a low incidence of peri-procedural complications. Larger studies with longer follow-up are warranted to further evaluate the safety and the efficacy of this device, especially at long-term follow-up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cuidados Posteriores , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Femenino , Humanos , Masculino , Alta del Paciente , Sistema de Registros , Resultado del Tratamiento
15.
ESC Heart Fail ; 9(5): 3188-3197, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35770333

RESUMEN

AIMS: Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve replacement (TAVR) have a concomitant diagnosis of CA. CA-AS population suffers from reduced functional capacity and worse prognosis than AS patients. As the prognostic impact of TAVR in patients with CA-AS has been historically questioned and in light of recently published evidence, we aim to provide a comprehensive synthesis of the efficacy and safety of TAVR in CA-AS patients. METHODS AND RESULTS: We performed a systematic review and meta-analysis of studies: (i) evaluating mortality with TAVR as compared with medical therapy in CA-AS patients and (ii) reporting complications and clinical outcomes of TAVR in CA-AS patients as compared with patients with AS alone. A total of seven observational studies were identified: four reported mortality with TAVR, and four reported complications and clinical outcomes after TAVR of patients with CA-AS compared with AS alone patients. In patients with CA-AS, the risk of mortality was lower with TAVR (n = 44) as compared with medical therapy (n = 36) [odds ratio (OR) 0.23, 95% confidence interval (CI) 0.07-0.73, I2  = 0%, P = 0.001, number needed to treat = 3]. The safety profile of TAVR seems to be similar in patients with CA-AS (n = 75) as compared with those with AS alone (n = 536), with comparable risks of stroke, vascular complications, life-threatening bleeding, acute kidney injury, and 30 day mortality, although CA-AS was associated with a trend towards an increased risk of permanent pacemaker implantation (OR 1.76, 95% CI 0.91-4.09, I2  = 0%, P = 0.085). CA is associated with a numerically higher rate of long-term mortality and rehospitalizations following TAVR in patients with CA-AS as compared with those with AS alone. CONCLUSIONS: TAVR is an effective and safe procedure in CA-AS patients, with a substantial survival benefit as compared with medical therapy, and a safety profile comparable with patients with AS alone except for a trend towards higher risk of permanent pacemaker implantation.


Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Amiloidosis/complicaciones , Amiloidosis/diagnóstico , Amiloidosis/cirugía
16.
Artículo en Inglés | MEDLINE | ID: mdl-34994882

RESUMEN

Increased sizes and dysfunction of the left atrium have been related to adverse outcomes. 3D-echocardiography is more accurate than 2D-echocardiography in estimating LA volumes and ejection fraction. However, the use of 3DE for LA analysis is limited by the absence of established reference values. We performed a systematic review and meta-analysis to provide reference ranges of LA maximum and minimum volumes indexed for body surface area (LAVi max and LAVi min, respectively), and LA-EF assessed by 3DE in healthy adults. Data search was conducted from inception through September 15, 2021, using the following Medical Subject Heading terms: left atrial/atrium, three-dimensional/3D echocardiography. The study protocol was registered in the PROSPERO database (CRD42021252428). 15 studies including 4,226 healthy adults (51% males) and reporting 3DE values of LAVi max, LAVi min and LA-EF were selected. LAVi max, LAVi min and LA-EF mean and reference values were equal to 25.18 ml/m2 (95% CI 23.10, 27.26), 11.10 ml/m2 (10.01, 12.18) and 55.94% (51.92, 59.96), respectively. No influential studies were identified. Pooled estimates per age group- and sex were also estimated. By meta-regression analyses, we identified variability in LA volumes and LA-EF depending on participants' age, ethnicity and number of heart cycles at 3D multi-beat acquisition. At individual patient data analysis conducted on 374 subjects, a software effect on LA-EF was shown. This systematic review and meta-analysis provides reference values of LAVi max, LAVi min and LA-EF assessed by 3DE in healthy adults, encouraging 3DE evaluation of the LA evaluation in daily practice.

17.
Artículo en Inglés | MEDLINE | ID: mdl-35006473

RESUMEN

Change in longitudinal left ventricular (LV) systolic function serves as an early marker of the deleterious effect of aortic stenosis (AS) and other cardiac comorbidities on cardiac function. We explored the prognostic value of tissue Doppler imaging (TDI)-derived longitudinal LV systolic function, defined by the peak systolic average of lateral and septal mitral annular velocities (average S') among symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). 297 consecutive patients with severe AS undergoing TAVI at three european centers with available average S' at preprocedural echocardiography were retrospectively included. The primary endpoint was the Kaplan Meier estimate of all-cause mortality. After a median 18 months (IQR 12-18) follow-up, 36 (12.1%) patients had died. Average S' was associated with all-cause mortality (per 1 cm/sec decrease: HR 1.29, 95%CI 1.03-1.60, p = 0.025), the cut-off of 6.5 cm/sec being the most accurate. Patients with average S' < 6.5 cm/sec (55.2%) presented characteristics of more advanced LV remodeling and functional impairment along with higher burden of cardiac comorbidities, and experienced higher all-cause mortality (17.6% vs. 7.5%, p = 0.007), also when adjusted for in-study outcome predictors (adj-HR: 2.69, 95%CI 1.22-5.93, p = 0.014). Results were consistent among patients with preserved ejection fraction, normal-flow AS, high-gradient AS and in those without LV hypertrophy. Longitudinal LV systolic function assessed by average S' is independently associated with long-term all-cause mortality among TAVI patients. An average S' below 6.5 cm/sec best defines clinically meaningful reduced longitudinal systolic function and may aid clinical risk stratification in these patients.

18.
Rev Cardiovasc Med ; 23(6): 199, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39077186

RESUMEN

Tricuspid valve disease represents a major health problem that affects a wide proportion of heart failure patients with a significant prognostic impact. In recent years an increasing number of minimally invasive and transcatheter treatments have been developed. The choice of the optimal transcatheter device therapy needs a careful patient selection and a dedicated anatomic assessment, mainly based on echocardiographic and computed tomography evaluation. Moreover, cardiac magnetic resonance has an established role in the functional assessment of right heart chambers with relevant prognostic implications. In this review we describe the role of multimodality imaging in the tricuspid valve disease assessment with an intervention-oriented perspective, from the pre-operative planning for different devices to the intraprocedural guide during transcatheter edge-to-edge repair.

19.
J Cardiovasc Med (Hagerstown) ; 22(11): 818-827, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34261078

RESUMEN

AIMS: Currently, there are few available data regarding a possible role for subclinical atherosclerosis as a risk factor for mortality in Coronavirus Disease 19 (COVID-19) patients. We used coronary artery calcium (CAC) score derived from chest computed tomography (CT) scan to assess the in-hospital prognostic role of CAC in patients affected by COVID-19 pneumonia. METHODS: Electronic medical records of patients with confirmed diagnosis of COVID-19 were retrospectively reviewed. Patients with known coronary artery disease (CAD) were excluded. A CAC score was calculated for each patient and was used to categorize them into one of four groups: 0, 1-299, 300-999 and at least 1000. The primary endpoint was in-hospital mortality for any cause. RESULTS: The final population consisted of 282 patients. Fifty-seven patients (20%) died over a follow-up time of 40 days. The presence of CAC was detected in 144 patients (51%). Higher CAC score values were observed in nonsurvivors [median: 87, interquartile range (IQR): 0.0-836] compared with survivors (median: 0, IQR: 0.0-136). The mortality rate in patients with a CAC score of at least 1000 was significantly higher than in patients without coronary calcifications (50 vs. 11%) and CAC score 1-299 (50 vs. 23%), P < 0.05. After adjusting for clinical variables, the presence of any CAC categories was not an independent predictor of mortality; however, a trend for increased risk of mortality was observed in patients with CAC of at least 1000. CONCLUSION: The correlation between CAC score and COVID-19 is fascinating and under-explored. However, in multivariable analysis, the CAC score did not show an additional value over more robust clinical variables in predicting in-hospital mortality. Only patients with the highest atherosclerotic burden (CAC ≥1000) could represent a high-risk population, similarly to patients with known CAD.


Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Mortalidad Hospitalaria , Calcificación Vascular/diagnóstico por imagen , COVID-19/diagnóstico , COVID-19/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Hospitalización/estadística & datos numéricos , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , SARS-CoV-2/aislamiento & purificación , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/epidemiología
20.
Front Cardiovasc Med ; 8: 670457, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34150868

RESUMEN

Prosthesis-patient mismatch (PPM) is present when the effective area of a prosthetic valve inserted into a patient is inferior to that of a normal human valve; the hemodynamic consequence of a valve too small compared with the size of the patient's body is the generation of higher than expected transprosthetic gradients. Despite evidence of increased risk of short- and long-term mortality and of structural valve degeneration in patients with PPM after surgical aortic valve replacement, its clinical impact in patients subject to transcatheter aortic valve implantation (TAVI) is yet unclear. We aim to review and update on the definition and incidence of PPM after TAVI, and its prognostic implications in the overall population and in higher-risk subgroups, such as small aortic annuli or valve-in-valve procedures. Last, we will focus on the armamentarium available in order to reduce risk of PPM when planning a TAVI procedure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA