Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nat Commun ; 15(1): 3969, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730242

RESUMEN

Encephalitis is a rare and potentially fatal manifestation of herpes simplex type 1 infection. Following genome-wide genetic analyses, we identified a previously uncharacterized and very rare heterozygous variant in the E3 ubiquitin ligase WWP2, in a 14-month-old girl with herpes simplex encephalitis. The p.R841H variant (NM_007014.4:c.2522G > A) impaired TLR3 mediated signaling in inducible pluripotent stem cells-derived neural precursor cells and neurons; cells bearing this mutation were also more susceptible to HSV-1 infection compared to control cells. The p.R841H variant increased TRIF ubiquitination in vitro. Antiviral immunity was rescued following the correction of p.R841H by CRISPR-Cas9 technology. Moreover, the introduction of p.R841H in wild type cells reduced such immunity, suggesting that this mutation is linked to the observed phenotypes.


Asunto(s)
Encefalitis por Herpes Simple , Herpesvirus Humano 1 , Mutación , Ubiquitina-Proteína Ligasas , Humanos , Ubiquitina-Proteína Ligasas/genética , Ubiquitina-Proteína Ligasas/metabolismo , Femenino , Encefalitis por Herpes Simple/genética , Lactante , Herpesvirus Humano 1/genética , Células Madre Pluripotentes Inducidas/metabolismo , Receptor Toll-Like 3/genética , Receptor Toll-Like 3/metabolismo , Ubiquitinación , Neuronas/metabolismo , Células-Madre Neurales/metabolismo , Células-Madre Neurales/virología , Sistemas CRISPR-Cas
2.
Front Cell Infect Microbiol ; 13: 1131241, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36936773

RESUMEN

Background: The microbial diagnosis of tuberculosis (TB) remains challenging and relies on multiple microbiological tests performed on different clinical specimens. Polymerase chain reactions (PCRs), introduced in the last decades has had a significant impact on the diagnosis of TB. However, questions remain about the use of PCRs in combination with conventional tests for TB, namely microscopy and culture. We aimed to determine the performance of microscopy, culture and PCR for the diagnosis of pulmonary tuberculosis according to the type of clinical specimen in order to improve the diagnostic yield and to avoid unnecessary, time and labor-intensive tests. Methods: We conducted a retrospective study (2008-2018) on analysis (34'429 specimens, 14'358 patients) performed in our diagnostic laboratory located in the Lausanne University Hospital to compare the performance of microbiological tests on sputum, induced sputum, bronchial aspirate and bronchoalveolar lavage (BAL). We analysed the performance using a classical "per specimen" approach and a "per patient" approach for paired specimens collected from the same patient. Results: The overall sensitivities of microscopy, PCR and culture were 0.523 (0.489, 0.557), 0.798 (0.755, 0.836) and 0.988 (0.978, 0.994) and the specificity were 0.994 (0.993, 0.995), 1 (0.999, 1) and 1 (1, 1). Microscopy displayed no significant differences in sensitivity according to the type of sample. The sensitivities of PCR for sputum, induced sputum, bronchial aspirate and BAL were, 0.821 (0.762, 0.871), 0.643 (0.480, 0.784), 0.837 (0.748, 0.904) and 0.759 (0.624, 0.865) respectively and the sensitivity of culture were, 0.993 (0.981, 0.998), 0.980 (0.931, 0.998), 0.965 (0.919, 0.988), and 1 (0.961, 1) respectively. Pairwise comparison of specimens collected from the same patient reported a significantly higher sensitivity of PCR on bronchial aspirate over BAL (p < 0.001) and sputum (p < 0.05) and a significantly higher sensitivity of culture on bronchial aspirate over BAL (p < 0.0001). Conclusions: PCR displayed a higher sensitivity and specificity than microscopy for all respiratory specimens, a rational for a smear-independent PCR-based approach to initiate tuberculosis microbial diagnostic. The diagnosis yield of bronchial aspirate was higher than BAL. Therefore, PCR should be systematically performed also on bronchial aspirates when available.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis Pulmonar , Tuberculosis , Humanos , Mycobacterium tuberculosis/genética , Estudios Retrospectivos , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/microbiología , Sensibilidad y Especificidad , Líquido del Lavado Bronquioalveolar/microbiología , Esputo/microbiología
3.
Swiss Med Wkly ; 152: w30168, 2022 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-35748764

RESUMEN

INTRODUCTION: While laboratories have been facing limited supplies of reagents for diagnostic tests throughout the course of the COVID-19 pandemic, national and international health plans, as well as billing costs, have been constantly adjusted in order to optimize the use of resources. We aimed to assess the impact of SARS-CoV-2 test costs and reimbursement tariff adjustments on diagnostic strategies in Switzerland to determine the advantages and disadvantages of different costs and resource saving plans. MATERIALS AND METHODS: We specifically assessed the cost of diagnostic SARS-COV-2 RT-PCR using five different approaches: i) in-house platform, ii) cobas 6800® (Roche, Basel, Switzerland), iii) GeneXpert® SARS-CoV-2 test (Cepheid, Sunnyvale, CA, USA), iv) VIASURE SARS-CoV-2 (N1 + N2) Real-Time PCR Detection Kit for BD MAX™ (Becton Dickinson, Franklin Lake, NJ, USA), v) cobas® Liat® SARS-CoV-2 & Influenza A/B (Roche, Basel, Switzerland). We compared these costs to the evolution of the reimbursement tariffs. RESULTS: The cost of a single RT-PCR test varied greatly (as did the volume of tests performed), ranging from as high as 180 CHF per test at the beginning of the pandemic (February to April 2020) to as low as 82 CHF per test at the end of 2020. Depending on the time period within the pandemic, higher costs did not necessarily mean greater benefits for the laboratories. The costs of molecular reagents for rapid tests were higher than of those for classic RT-PCR platforms, but the rapid tests had reduced turnaround times (TATs), thus improving patient care and enabling more efficient implementation of isolation measures, as well as reducing the burden of possible nosocomial infections. At the same time, there were periods when the production or distribution of these reagents was insufficient, and only the use of several different molecular platforms allowed us to sustain the high number of tests requested. CONCLUSIONS: Cost-saving plans need to be thoroughly assessed and constantly adjusted according to the epidemiological situation, the clinical context and the national resources in order to always guarantee that the highest performing diagnostic solutions are available. Not all cost-saving strategies guarantee good analytical performance.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Humanos , Pandemias , Sensibilidad y Especificidad
4.
Microbiol Spectr ; 10(3): e0037922, 2022 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-35583335

RESUMEN

Timely identification of a pathogen in lower respiratory tract infections (LRTI) can support appropriate antibiotics use. The difficulty of obtaining lower respiratory tract (LRT) samples limits the utility of point-of-care syndromic molecular assays. We assessed the performance of the FilmArray Pneumonia plus panel (FilmArray PP) in nasopharyngeal (NP) swab for detection of Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis. Patients in the study included retrospectively consenting adults who attended the emergency department of Lausanne University Hospital between February 2019 and August 2020 for a community-acquired LRTI, with available NP swab and a high-quality LRT sample. These samples were tested with the FilmArray PP (cutoff of ≥104 copies/mL). Positive (PPA) and negative percent agreement (NPA) of FilmArray PP in NP swab were calculated, using (i) FilmArray PP in LRT sample and (ii) standard microbiological tests as reference standards. To assess the performance of a lower detection cutoff, NP samples were also tested with an in-house PCR (cutoff of ≥10 copies/mL) for S. pneumoniae and H. influenzae. Overall, 118 patients were included. FilmArray PP in LRT sample and standard microbiology tests detected S. pneumoniae in 19/118 and 12/118, H. influenzae in 44/118 and 19/118, and M. catarrhalis in 14/118 and 0/118, respectively. Using LRT FilmArray PP as reference, PPA and NPA of FilmArray PP on NP were 58% and 100% for S. pneumoniae, 61% and 100% for H. influenzae, and 57% and 99% for M. catarrhalis. Using standard diagnostic tests as reference, PPA and NPA were 58% and 96% for S. pneumoniae, 74% and 87% for H. influenzae, and indefinite and 92% for M. catarrhalis. Using a lower cutoff on NP (≥102 copies/mL), PPA was 68% for S. pneumoniae and 77% for H. influenzae with LRT FilmArray PP as reference. FilmArray PP in NP swabs has a limited PPA for identifying the most common etiologies of community-acquired LRTI irrespective of the reference standard, preventing its use for withholding antibiotics. The PCR detection cutoff does not explain the low PPA. The excellent NPA suggests the use of NP PCR results for rapidly targeted antimicrobial therapy. IMPORTANCE Timely identification of a pathogen in patients with lower respiratory tract infections is of paramount importance to avoid inappropriate antibiotic prescription. We aimed to evaluate the performance of a rapid syndromic molecular assay in nasopharyngeal swabs for identifying the most common bacterial causes of lower respiratory tract infections in adults (Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis). Our data show that nasopharyngeal molecular assay has a good concordance with lower respiratory tract sample when positive but not when negative. A positive result is therefore concordant with a lower respiratory tract infection and can be used to target antibiotics. Nevertheless, a negative result does not have a good concordance, so it cannot be used to withhold antibiotics. Our findings illustrate the potential utility of these easily collected samples for the management of patients with lower respiratory tract infections.


Asunto(s)
Infecciones Comunitarias Adquiridas , Neumonía , Infecciones del Sistema Respiratorio , Adulto , Antibacterianos/farmacología , Bacterias , Infecciones Comunitarias Adquiridas/diagnóstico , Infecciones Comunitarias Adquiridas/microbiología , Haemophilus influenzae/genética , Humanos , Moraxella catarrhalis/genética , Nasofaringe/microbiología , Neumonía/microbiología , Reacción en Cadena de la Polimerasa , Infecciones del Sistema Respiratorio/microbiología , Estudios Retrospectivos , Streptococcus pneumoniae/genética
5.
J Cyst Fibros ; 21(2): e158-e164, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34756681

RESUMEN

BACKGROUND: Various bacterial and viral assemblages composing Cystic Fibrosis (CF) lung microbiota contribute to long-term lung function decline over time. Yet, the impact of individual microorganisms on pulmonary functions remains uncertain in children with CF. METHODS: As part of the 'Mucoviscidosis, respiratory VIruses, intracellular Bacteria and fastidious organisms'' project, children with CF were longitudinally followed in a Swiss multicentric study. Respiratory samples included mainly throat swabs and sputa samples for bacterial culture and 16S rRNA metagenomics and nasopharyngeal swabs for respiratory virus detection by molecular assays. Percentage of predicted Forced Expiratory Volume in one second (FEV1%) and Lung Clearance Index (LCI) were recorded. RESULTS: Sixty-one children, of whom 20 (32.8%) presented with at least one pulmonary exacerbation, were included. Almost half of the 363 nasopharyngeal swabs tested by RT-PCR were positive for a respiratory virus, mainly rhinovirus (26.5%). From linear mixed-effects regression models, P. aeruginosa (-11.35, 95%CI [-17.90; -4.80], p = 0.001) was significantly associated with a decreased FEV1%, whereas rhinovirus was associated with a significantly higher FEV1% (+4.24 95%CI [1.67; 6.81], p = 0.001). Compared to conventional culture, 16S rRNA metagenomics showed a sensitivity and specificity of 80.0% and 85.4%, respectively for detection of typical CF pathogens. However, metagenomics detected a bacteria almost twice more often than culture. CONCLUSIONS: As expected, P. aeruginosa impacted negatively on FEV1% while rhinovirus was surprisingly associated with better FEV1%. Culture-free assays identifie significantly more pathogens than standard culture, with disputable clinical correlation.


Asunto(s)
Fibrosis Quística , Bacterias , Niño , Fibrosis Quística/complicaciones , Fibrosis Quística/diagnóstico , Fibrosis Quística/microbiología , Volumen Espiratorio Forzado , Humanos , Pulmón , Pseudomonas aeruginosa , ARN Ribosómico 16S/genética , Rhinovirus
6.
Microorganisms ; 9(9)2021 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-34576805

RESUMEN

Saliva sampling could serve as an alternative non-invasive sample for SARS-CoV-2 diagnosis while rapid antigen tests (RATs) might help to mitigate the shortage of reagents sporadically encountered with RT-PCR. Thus, in the RESTART study we compared antigen and RT-PCR testing methods on nasopharyngeal (NP) swabs and salivary samples. We conducted a prospective observational study among COVID-19 hospitalized patients between 10 December 2020 and 1 February 2021. Paired saliva and NP samples were investigated by RT-PCR (Cobas 6800, Roche-Switzerland, Basel, Switzerland) and by two rapid antigen tests: One Step Immunoassay Exdia® COVID-19 Ag (Precision Biosensor, Daejeon, Korea) and Standard Q® COVID-19 Rapid Antigen Test (Roche-Switzerland). A total of 58 paired NP-saliva specimens were collected. A total of 32 of 58 (55%) patients were hospitalized in the intensive care unit, and the median duration of symptoms was 11 days (IQR 5-19). NP and salivary RT-PCR exhibited sensitivity of 98% and 69% respectively, whereas the specificity of these RT-PCRs assays was 100%. The NP RATs exhibited much lower diagnostic performance, with sensitivities of 35% and 41% for the Standard Q® and Exdia® assays, respectively, when a wet-swab approach was used (i.e., when the swab was diluted in the viral transport medium (VTM) before testing). The sensitivity of the dry-swab approach was slightly better (47%). These antigen tests exhibited very low sensitivity (4% and 8%) when applied to salivary swabs. Nasopharyngeal RT-PCR is the most accurate test for COVID-19 diagnosis in hospitalized patients. RT-PCR on salivary samples may be used when nasopharyngeal swabs are contraindicated. RATs are not appropriate for hospitalized patients.

7.
Pediatr Infect Dis J ; 40(8): e300-e304, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34250969

RESUMEN

BACKGROUND: Saliva reverse transcriptase-Polymerase chain reaction (RT-PCR) is an attractive alternative for the detection of severe acute respiratory syndrome coronavirus 2 in adults with less known in children. METHODS: Children with coronavirus disease 2019 symptoms were prospectively enrolled in a 1-month comparative clinical trial of saliva and nasopharyngeal (NP) RT-PCR. Detection rates and sensitivities of saliva and NP RT-PCR were compared as well as discordant NP and saliva RT-PCR findings including viral loads (VLs). RESULTS: Of 405 patients enrolled, 397 patients had 2 tests performed. Mean age was 12.7 years (range, 1.2-17.9). Sensitivity of saliva was 85.2% (95% confidence interval: 78.2%-92.1%) when using NP as the standard; sensitivity of NP was 94.5% (89.8%-99.2%) when saliva was considered as the standard. For a NP RT-PCR VL threshold of ≥103 and ≥104 copies/mL, sensitivity of saliva increases to 88.7% and 95.2%, respectively. Sensitivity of saliva and NP swabs was, respectively, 89.5% and 95.3% in patient with symptoms less than 4 days (P = 0.249) and 70.0% and 95.0% in those with symptoms ≥4-7 days (P = 0.096). The 15 patients who had an isolated positive NP RT-PCR were younger (P = 0.034), had lower NP VL (median 5.6 × 103 vs. 3.9 × 107, P < 0.001), and could not drool saliva at the end of the sampling (P = 0.002). VLs were lower with saliva than with NP RT-PCR (median 8.7 cp/mL × 104; interquartile range 1.2 × 104-5.2 × 105; vs. median 4.0 × 107 cp/mL; interquartile range, 8.6 × 105-1 × 108; P < 0.001). CONCLUSIONS: While RT-PCR testing on saliva performed more poorly in younger children and likely after longer duration of symptoms, saliva remains an attractive alternative to NP swabs in children.


Asunto(s)
Prueba de COVID-19 , COVID-19/diagnóstico , COVID-19/virología , Nasofaringe/virología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Niño , Preescolar , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , SARS-CoV-2/genética , Sensibilidad y Especificidad , Manejo de Especímenes , Carga Viral
8.
Microorganisms ; 9(4)2021 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-33920307

RESUMEN

Following the Swiss Federal Office of Public Health (FOPH) authorization of the rapid antigen test (RAT), we implemented the use of the RAT in the emergency ward of our university hospital for patients' cohorting. RAT triaging in association with RT-PCR allowed us to promptly isolate positive patients and save resources. Among 532 patients, overall sensitivities were 48.3% for Exdia and 41.2% for Standard Q®, PanbioTM and BD Veritor™. All RATs exhibited specificity above 99%. Sensitivity increased to 74.6%, 66.2%, 66.2% and 64.8% for Exdia, Standard Q®, PanbioTM and BD Veritor™, respectively, for viral loads above 105 copies/mL, to 100%, 97.8%, 96.6% and 95.6% for viral loads above 106 copies/mL and 100% for viral loads above 107 copies/mL. Sensitivity was significantly higher for patients with symptoms onset within four days (74.3%, 69.2%, 69.2% and 64%, respectively) versus patients with the evolution of symptoms longer than four days (36.8%, 21.1%, 21.1% and 23.7%, respectively). Among COVID-19 asymptomatic patients, sensitivity was 33%. All Immunoglobulin-A-positive patients resulted negative for RAT. The RAT might represent a useful resource in selected clinical settings as a complementary tool in RT-PCR for rapid patient triaging, but the lower sensitivity, especially in late presenters and COVID-19 asymptomatic subjects, must be taken into account.

9.
Pathog Dis ; 79(1)2021 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-33247928

RESUMEN

OBJECTIVES: The contribution of intracellular and fastidious bacteria in Cystic fibrosis (CF) pulmonary exacerbations, and progressive lung function decline remains unknown. This project aimed to explore their impact on bacterial microbiota diversity over time in CF children. METHODS: Sixty-one children enrolled in the MUCOVIB multicentre prospective cohort provided 746 samples, mostly nasopharyngeal swabs, throat swabs and sputa which were analysed using culture, specific real-time qPCRs and 16S rRNA amplicon metagenomics. RESULTS: Chlamydia pneumoniae (n = 3) and Mycoplasma pneumoniae (n = 1) were prospectively documented in 6.6% of CF children. Microbiota alpha-diversity in children with a documented C. pneumoniae was highly variable, similarly to children infected with Staphylococcus aureus or Pseudomonas aeruginosa. The transition from routine follow-up visits to pulmonary exacerbation (n = 17) yielded variable changes in diversity indexes with some extreme loss of diversity. CONCLUSIONS: The high rate of C. pneumoniae detection supports the need for regular screenings in CF patients. A minor impact of C. pneumoniae on the microbial community structure was documented. Although detected in a single patient, M. pneumoniae should also be considered as a possible aetiology of lung infection in CF subjects.


Asunto(s)
Chlamydophila pneumoniae/aislamiento & purificación , Fibrosis Quística/microbiología , Microbiota , Mycoplasma pneumoniae/aislamiento & purificación , Sistema Respiratorio/microbiología , Biodiversidad , Niño , Preescolar , Infecciones por Chlamydophila/microbiología , Chlamydophila pneumoniae/genética , ADN Bacteriano , Humanos , Metagenómica , Mycoplasma pneumoniae/genética , Neumonía por Mycoplasma/microbiología , Estudios Prospectivos , ARN Ribosómico 16S , Esputo/microbiología
10.
Pathog Dis ; 78(8)2020 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-33030200

RESUMEN

OBJECTIVES: In order to cope with the rapid spread of the COVID-19 pandemic, we introduced on our in-house high-throughput molecular diagnostic platform (MDx Platform) a real-time reverse transcriptase PCR (RT-PCR) to detect the SARS-CoV-2 from any clinical specimens. The aim of this study was to compare the RT-PCR results obtain with the MDx Platform and the commercial assay cobas SARS-CoV-2 (Roche) on nasopharyngeal swab and other clinical specimens including sputum, bronchial aspirate, bronchoalveolar lavage and anal swabs. METHODS: Samples received in our laboratory from patients suspected of COVID-19 (n = 262) were tested in parallel with our MDx platform SARS-CoV-2 PCR and with the cobas SARS-CoV-2 test. RESULTS: The overall agreement between the two tests for all samples tested was 99.24% (260/262), which corresponded to agreements of 100% (178/178) on nasopharyngeal swabs, 95.45% (42/44) on lower respiratory tract specimen with discordant resultS obtained for very high cycle threshold (Ct) value and 100% (40/40) on anorectal swabs. The Ct values for nasopharyngeal swabs displayed an excellent correlation (R2 > 96%) between both tests. CONCLUSIONS: The high agreements between the cobas SARS-CoV-2 test and the MDx platform supports the use of both methods for the diagnostic of COVID-19 on various clinical samples. Very few discrepant results may occur at very low viral load.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/diagnóstico , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/métodos , Neumonía Viral/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , COVID-19 , Infecciones por Coronavirus/virología , Humanos , Nasofaringe/virología , Pandemias , Neumonía Viral/virología , SARS-CoV-2
11.
Methods Mol Biol ; 1616: 171-181, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28600769

RESUMEN

The advances in molecular biology of the last decades have dramatically improved the field of diagnostic bacteriology. In particular, PCR-based technologies have impacted the diagnosis of infections caused by obligate intracellular bacteria such as pathogens from the Chlamydiacae family. Here, we describe a real-time PCR-based method using the Taqman technology for the diagnosis of Chlamydia pneumoniae, Chlamydia psittaci, and Chlamydia abortus infection. The method presented here can be applied to various clinical samples and can be adapted on opened molecular diagnostic platforms.


Asunto(s)
Infecciones por Chlamydia/diagnóstico , Infecciones por Chlamydophila/diagnóstico por imagen , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Animales , Infecciones por Chlamydia/microbiología , Infecciones por Chlamydophila/microbiología , Chlamydophila pneumoniae/patogenicidad , Chlamydophila psittaci/patogenicidad , Humanos , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/métodos , Psitacosis/diagnóstico , Psitacosis/microbiología
12.
Future Microbiol ; 11(3): 403-25, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27028061

RESUMEN

A 10-year experience of our automated molecular diagnostic platform that carries out 91 different real-time PCR is described. Progresses and future perspectives in molecular diagnostic microbiology are reviewed: why automation is important; how our platform was implemented; how homemade PCRs were developed; the advantages/disadvantages of homemade PCRs, including the critical aspects of troubleshooting and the need to further reduce the turnaround time for specific samples, at least for defined clinical settings such as emergencies. The future of molecular diagnosis depends on automation, and in a novel perspective, it is time now to fully acknowledge the true contribution of molecular diagnostic and to reconsider the indication for PCR, by also using these tests as first-line assays.


Asunto(s)
Automatización , Infecciones/diagnóstico , Técnicas de Diagnóstico Molecular , Reacción en Cadena en Tiempo Real de la Polimerasa , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA