1.
Indian J Cancer ; 54(1): 379-384, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29199727

RESUMEN

BACKGROUND: Better conformity may help in delivering minimum dose to organs at risk (OARs) and maximum dose to planning target volume (PTV). As per the requirements of modern radiotherapy, 95% isodose should cover the PTV, so conformity indices (CIs) are used for evaluating quality of conformation of treatment plans. AIM: This study aimed to investigate degree of conformity for pelvic patients using intensity-modulated radiotherapy (IMRT) technique. Three formulas of CIs described in literature were analyzed in this study. SETTINGS AND DESIGN: This study was performed to evaluate degree of conformity of 18 patients treated with radiotherapy treatment plan using cumulative dose volume histogram. Effectiveness of different CIs was explored for IMRT plans using 15 MV photon beam. Doses delivered to OAR were also studied. STATISTICAL ANALYSIS USED: CI suggested by the International Commission on Radiation Units and Measurements, radiation CI and CI prescription isodose to target volume (PITV) had mean ± standard deviation values of 1.02 ± 0.018, 0.98 ± 0.017, and 1.63 ± 0.333, respectively. RESULTS AND CONCLUSION: Dose distribution for all patients was highly conformal and clinically acceptable. Values of CI PITV exceeded acceptable value for 27% patients with minor deviation. No statistically significant differences were observed for three CIs reported. Target volume lies between 95% and 107% of prescribed dose which shows ideal target coverage. This simple parameter is advantageous since it is easy to interpret and helped determine quality of treatment plan. This study clearly demonstrated that favorable dose distribution in PTV and OARs is achieved using IMRT technique, and hence, the risk of damage to normal tissues is reduced.


Asunto(s)
Neoplasias Pélvicas/epidemiología , Neoplasias Pélvicas/radioterapia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Pélvicas/patología , Pelvis/patología , Pelvis/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
2.
Br J Radiol ; 86(1031): 20130390, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24049129

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate spot scanning proton therapy with an anthropomorphic prostate phantom at the Proton Therapy Center of The University of Texas MD Anderson Cancer Center at Houston, TX (PTCH). METHODS: An anthropomorphic prostate phantom from the Radiological Physics Center (RPC), The University of Texas MD Anderson Cancer Center, Houston, TX, was used, which contained thermoluminescent dosemeters and GAFCHROMIC(®) EBT2 film (ISP Technologies, Wayne, NJ). The phantom was irradiated by the Hitachi synchrotron (Hitachi America, Ltd, Tarrytown, NY), and the results were compared between the treatment planning system (TPS) and RPC measurements. RESULTS: RPC results show that the right/left, inferior/superior and posterior/anterior aspects of the coronal/sagittal and EBT2 film measurements were within ±7%/±4 mm of the TPS. The RPC thermoluminescent dosemeter measurements of the prostate and femoral heads were within 3% of the TPS. CONCLUSION: The RPC prostate phantom is a useful mechanism to evaluate spot scanning beam proton therapy within certain confidence levels. ADVANCES IN KNOWLEDGE: The RPC anthropomorphic prostate phantom could be used to establish quality assurance of spot scanning proton beam for patients with prostate cancer.


Asunto(s)
Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Terapia de Protones/instrumentación , Terapia de Protones/normas , Humanos , Masculino , Próstata/patología , Próstata/efectos de la radiación , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Sincrotrones