RESUMEN
To test the hypothesis that cine MRI-derived radiomics features of the cardiac blood pool can represent hemodynamic characteristics of pulmonary hypertension-heart failure with preserved ejection fraction (PH-HFpEF). Nineteen PH-HFpEF patients (9 male, 57.8 ± 14.7 years) and 19 healthy controls (13 male, 50.3 ± 13.6 years) were enrolled. All participants underwent a cardiac MRI scan. One hundred and seven radiomics features (7 classes) of the blood pool in the left and right ventricles/atrium (LV/RV/LA/RA) were extracted from 4-chamber cine (2D images) at the stages of systole, rapid filling, diastasis, and atrial contraction within a cardiac cycle. For PH-HFpEF patients, features acquired from LV/LA were related to the pulmonary capillary wedge pressure (PCWP); features acquired from RV/RA were related to the mean pulmonary artery pressure (mPAP) using the Pearson correlation coefficient (r). Logistic regression, receiver operating characteristic (ROC) curve and the area under the curve (AUC) were used to test the capability of radiomics features in discriminating 2 subject groups. Features acquired from different chambers at various periods present diverse properties in representing hemodynamic indices of PH-HFpEF. Multiple radiomics features blood pool were significantly related to PCWP and/or mPAP (r: 0.4-0.679, p < 0.05). In addition, multiple features of blood pools acquired at various time points within a cardiac cycle can efficiently discriminate PH-HFpEF from controls (individual AUC: 0.7-0.864). Cine MRI-derived radiomics features of the cardiac blood pool have the potential to characterize hemodynamic abnormalities in the context of PH-HFpEF.
Asunto(s)
Insuficiencia Cardíaca , Hemodinámica , Hipertensión Pulmonar , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Función Ventricular Derecha , Humanos , Masculino , Persona de Mediana Edad , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Anciano , Estudios de Casos y Controles , Adulto , Presión Esfenoidal Pulmonar , Presión Arterial , Interpretación de Imagen Asistida por Computador , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/diagnóstico por imagen , RadiómicaRESUMEN
Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.
Asunto(s)
Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Adulto , Humanos , Masculino , Niño , Persona de Mediana Edad , Estudios Retrospectivos , Taquipnea , Hiperventilación , Arritmias CardíacasRESUMEN
Although cine MRI-derived radiomics features in the cardiac blood pool have been used to represent cardiac function and motion, the clinical relevance of radiomics features in the great vessels is still unknown. The aim of the present study was to test the hypothesis that cine MRI-derived radiomics features of the pulmonary artery (PA) can represent hemodynamic abnormalities in pulmonary hypertension (PH). With the approval of the institutional review board (IRB), 50 PH patients (21 males, 36-89 years old, diagnosed with right heart catheterization [RHC]) and 23 healthy volunteers (14 males, 26-80 years old) were retrospectively enrolled in this study. All participants underwent cardiac 4D flow and cine MRI (25 retrospective phases) at the right ventricular (RV) outflow tract (RVOT). A total of 93 radiomics features were extracted from RVOT cine images through a fixed size region of interest (ROI) at the proximal part of the PA. The peak values of the 6 first order features were different between the PH patients and controls. 4D flow-derived mean velocity in PA was related to 'Kurtosis' (r = 0.452,), 'Range' (r = 0.426), 'Autocorrelation' (r = 0.407), 'Joint Average' (r = 0.459), 'Sum Average' (r = 0.459), 'High Gray Level Emphasis' (r = 0.41), 'Large Dependence High Gray Level Emphasis' (r = 0.44), 'High Gray Level Run Emphasis' (r = 0.422), 'Gray Level Variance' (r = 0.419), 'High Gray Level Zone Emphasis' (r = 0.451), and 'Small Area High Gray Level Emphasis' (r = 0.415). Mean RV pressure was related to 'Inverse Variance' (r = 0.43) and 'Run Percentage' (r = 0.403). All p values < 0.05. Cine MRI-derived PA radiomics features have the potential to serve as novel imaging biomarkers for representing hemodynamic changes in pulmonary circulation.
Asunto(s)
Hipertensión Pulmonar , Imagen por Resonancia Cinemagnética , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Imagen por Resonancia Cinemagnética/métodos , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Radiómica , Valor Predictivo de las Pruebas , HemodinámicaRESUMEN
Four-dimensional flow MRI is a powerful phase contrast technique used for assessing three-dimensional (3D) blood flow dynamics. By acquiring a time-resolved velocity field, it enables flexible retrospective analysis of blood flow that can include qualitative 3D visualization of complex flow patterns, comprehensive assessment of multiple vessels, reliable placement of analysis planes, and calculation of advanced hemodynamic parameters. This technique provides several advantages over routine two-dimensional flow imaging techniques, allowing it to become part of clinical practice at major academic medical centers. In this review, we present the current state-of-the-art cardiovascular, neurovascular, and abdominal applications.
Asunto(s)
Hemodinámica , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Velocidad del Flujo Sanguíneo/fisiología , Hemodinámica/fisiología , Corazón , Imagenología Tridimensional/métodosRESUMEN
BACKGROUND: The distal superficial femoral artery (SFA) is most commonly affected in peripheral artery disease (PAD). The effects of the proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitor alirocumab added to statin therapy on SFA atherosclerosis, downstream flow, and walking performance are unknown. METHODS: Thirty-five patients with PAD on maximally tolerated statin therapy were recruited. Patients were randomized to alirocumab 150 mg subcutaneously (n = 18) or matching placebo (n = 17) therapy every 2 weeks for 1 year. The primary outcome was change in SFA plaque volume by black blood magnetic resonance imaging (MRI). Secondary outcomes were changes in calf muscle perfusion by cuff/occlusion hyperemia arterial spin labeling MRI, 6-minute walk distance (6MWD), low-density lipoprotein (LDL) cholesterol, and other biomarkers. RESULTS: Age (mean ± SD) was 64 ± 8 years, 20 (57%) patients were women, 17 (49%) were Black individuals, LDL was 107 ± 36 mg/dL, and the ankle-brachial index 0.71 ± 0.20. The LDL fell more with alirocumab than placebo (mean [95% CI]) (-49.8 [-66.1 to -33.6] vs -7.7 [-19.7 to 4.3] mg/dL; p < 0.0001). Changes in SFA plaque volume and calf perfusion showed no difference between groups when adjusted for baseline (+0.25 [-0.29 to 0.79] vs -0.04 [-0.47 to 0.38] cm3; p = 0.37 and 0.22 [-8.67 to 9.11] vs 3.81 [-1.45 to 9.08] mL/min/100 g; p = 0.46, respectively), nor did 6MWD. CONCLUSION: In this exploratory study, the addition of alirocumab therapy to statins did not alter SFA plaque volume, calf perfusion or 6MWD despite significant LDL lowering. Larger studies with longer follow up that include plaque characterization may improve understanding of the effects of intensive LDL-lowering therapy in PAD (ClinicalTrials.gov Identifier: NCT02959047).
Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Enfermedad Arterial Periférica , Placa Aterosclerótica , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Proproteína Convertasa 9/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Anticuerpos Monoclonales/efectos adversos , LDL-Colesterol/uso terapéutico , Placa Aterosclerótica/inducido químicamente , Placa Aterosclerótica/tratamiento farmacológico , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/tratamiento farmacológico , Músculos , Resultado del Tratamiento , Método Doble CiegoRESUMEN
Native T1, extracellular volume fraction (ECV), and late gadolinium enhancement (LGE) characterize myocardial tissue and relate to patient prognosis in a variety of diseases, including pulmonary hypertension. The purpose of this study was to evaluate if left ventricle (LV) fibrosis measurements have prognostic value for cardiac outcomes in pulmonary hypertension subgroups. 54 patients with suspected pulmonary hypertension underwent right-heart catheterization and were classified into pulmonary hypertension subgroups: pre-capillary component (PreCompPH) and isolated post-capillary (IpcPH). Cardiac magnetic resonance imaging (MRI) scans were performed with the acquisition of balanced cine steady-state free precession, native T1, and LGE pulse sequences to measure cardiac volumes and myocardial fibrosis. Associations between cardiac events and cardiac MRI measurements were analyzed within PreCompPH and IpcPH patients. IpcPH: LV native T1 was higher in patients who experienced a cardiac event within two years vs. those who did not. In patients with LV native T1 > 1050 ms, the rate of cardiac events was higher. ECV and quantitative LGE did not differ between groups. PreCompPH: native T1, ECV, and quantitative/qualitative LGE did not differ between patients who experienced a cardiac event within two years vs. those who did not. LV native T1 may have potential value for forecasting cardiac events in IpcPH, but not in PreCompPH, patients.
Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Valor Predictivo de las Pruebas , Aorta/cirugía , Disección Aórtica/diagnóstico por imagen , Hemodinámica , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Resultado del Tratamiento , Aorta TorácicaRESUMEN
BACKGROUND: Bicuspid aortic valve (BAV) disease is associated with increased risk of aortopathy. In addition to current intervention guidelines, BAV mediated changes in aortic 3D hemodynamics have been considered as risk stratification measures. We aimed to evaluate the association of 4D flow cardiovascular magnetic resonance (CMR) derived voxel-wise aortic reverse flow with aortic dilation and to investigate the role of aortic valve regurgitation (AR) and stenosis (AS) on reverse flow in systole and diastole. METHODS: 510 patients with BAV (52 ± 14 years) and 120 patients with trileaflet aortic valve (TAV) (61 ± 11 years) and mid-ascending aorta diameter (MAAD) > 35 mm who underwent CMR including 4D flow CMR were retrospectively included. An age and sex-matched healthy control cohort (n = 25, 49 ± 12 years) was selected. Voxel-wise reverse flow was calculated in the aorta and quantified by the mean reverse flow in the ascending aorta (AAo) during systole and diastole. RESULTS: BAV patients without AS and AR demonstrated significantly increased systolic and diastolic reverse flow (222% and 13% increases respectively, p < 0.01) compared to healthy controls and also had significantly increased systolic reverse flow compared to TAV patients with aortic dilation (79% increase, p < 0.01). In patients with isolated AR, systolic and diastolic AAo reverse flow increased significantly with AR severity (c = - 83.2 and c = - 205.6, p < 0.001). In patients with isolated AS, AS severity was associated with an increase in both systolic (c = - 253.1, p < 0.001) and diastolic (c = - 87.0, p = 0.02) AAo reverse flow. Right and left/right and non-coronary fusion phenotype showed elevated systolic reverse flow (> 17% increase, p < 0.01). Right and non-coronary fusion phenotype showed decreased diastolic reverse flow (> 27% decrease, p < 0.01). MAAD was an independent predictor of systolic (p < 0.001), but not diastolic, reverse flow (p > 0.1). CONCLUSION: 4D flow CMR derived reverse flow associated with BAV was successfully captured even in the absence of AR or AS and in comparison to TAV patients with aortic dilation. Diastolic AAo reverse flow increased with AR severity while AS severity strongly correlated with increased systolic reverse flow in the AAo. Additionally, increasing MAAD was independently associated with increasing systolic AAo reverse flow. Thus, systolic AAo reverse flow may be a valuable metric for evaluating disease severity in future longitudinal outcome studies.
Asunto(s)
Enfermedades de la Aorta , Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Estudios Transversales , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Dilatación , Valor Predictivo de las Pruebas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/patología , Enfermedades de la Aorta/complicaciones , Hemodinámica , Espectroscopía de Resonancia MagnéticaRESUMEN
BACKGROUND: Although radiomics features of the left ventricular wall have been used to assess cardiac diseases, radiomics features of the cardiac blood pool have been relatively ignored. PURPOSE: To test the hypothesis that cine MRI-derived radiomics features of the cardiac blood pool are associated with cardiac function and motion. STUDY TYPE: Retrospective. POPULATION: A total of 26 healthy volunteers (51.2 ± 15.6 years; 17 males). FIELD STRENGTH/SEQUENCE: A 1.5 T/balanced steady-state free precession (bSSFP). ASSESSMENT: The radiomics features (107 features in seven classes) of the blood pool of the left/right ventricle/atrium (LV/RV/LA/RA) were extracted on four-chamber cine images (25 phases). Conventional cardiac function parameters (volumes, ejection fraction [EF] and longitudinal strain) were assessed in each cardiac chamber. Intraobserver- and interobserver agreements of radiomics features of all chambers acquired at all phases were assessed, as well as scan-rescan agreement in a subset of 13 volunteers. STATISTICAL TESTS: Pearson correlation coefficients (r) were used to assess the associations between peak values of radiomics features and end-diastolic (or maximal) volume, end-systolic (or minimal) volume, EF, and longitudinal strain of corresponding chambers. Good intraobserver, interobserver, and scan-rescan agreements for radiomics features acquired were defined as intraclass correlation coefficient (ICC) > 0.7 or coefficient of variation (CoV) < 20%. RESULTS: Most radiomics features of the blood pool varied periodically throughout the cardiac cycle. Peak values of chamber-specific blood pool radiomics features were correlated with traditional cardiac function and motion indices of corresponding chambers (r: 0.4-0.87). Ninety-three (87%), 86 (80%), and 73 (68%) radiomics features demonstrated good intraobserver, interobserver, and scan-rescan reproducibility, respectively. CONCLUSION: Cine MRI-derived radiomics features within LV/RV/LA/RA are associated with traditional cardiac function and motion indices of corresponding chambers and may have the potential to become novel quantitative imaging biomarkers in cardiovascular medicine. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: 1.
Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Cinemagnética , Masculino , Humanos , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados , Ventrículos Cardíacos/diagnóstico por imagen , Atrios Cardíacos , Volumen Sistólico , Función Ventricular IzquierdaRESUMEN
BACKGROUND: Pulmonary hypertension (PH) contributes to restricted flow through the pulmonary circulation characterized by elevated mean pulmonary artery pressure acquired from invasive right heart catheterization (RHC). MRI may provide a noninvasive alternative for diagnosis and characterization of PH. PURPOSE: To characterize PH via quantification of regional pulmonary transit times (rPTT). STUDY TYPE: Retrospective. POPULATION: A total of 43 patients (58% female); 24 controls (33% female). RHC-confirmed patients classified as World Health Organization (WHO) subgroups 1-4. FIELD STRENGTH/SEQUENCE: A 1.5 T/time-resolved contrast-enhanced MR Angiography (CE-MRA). ASSESSMENT: CE-MRA data volumes were combined into a 4D matrix (3D resolution + time). Contrast agent arrival time was defined as the peak in the signal-intensity curve generated for each voxel. Average arrival times within a vessel region of interest (ROI) were normalized to the main pulmonary artery ROI (t0 ) for eight regions to define rPTT for all subjects. Subgroup analysis included grouping the four arterial and four venous regions. Intraclass correlation analysis completed for reproducibility. STATISTICAL TESTS: Analysis of covariance with age as covariate. A priori Student's t-tests or Wilcoxon rank-sum test; α = 0.05. Results compared to controls unless noted. Significant without listing P value. ICC ran as two-way absolute agreement model with two observers. RESULTS: PH patients demonstrated elevated rPTT in all vascular regions; average rPTT increase in arterial and venous branches was 0.85 ± 0.15 seconds (47.7%) and 1.0 ± 0.18 seconds (16.9%), respectively. Arterial rPTT was increased for all WHO subgroups; venous regions were elevated for subgroups 2 and 4 (group 1, P = 0.86; group 3, P = 0.32). No significant rPTT differences were found between subgroups (P = 0.094-0.94). Individual vessel ICC values ranged from 0.58 to 0.97. DATA CONCLUSION: Noninvasive assessment of PH using standard-of-care time-resolved CE-MRA can detect increased rPTT in PH patients of varying phenotypes compared to controls. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.
Asunto(s)
Hipertensión Pulmonar , Femenino , Masculino , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Arteria Pulmonar/diagnóstico por imagen , Medios de ContrasteRESUMEN
PURPOSE: We assessed the impact of bicuspid aortic valve (BAV), aortic stenosis (AS), and regurgitation (AR) on the metrics of left ventricular (LV) remodeling, as measured by electrocardiogram (ECG), transthoracic echocardiography (TTE), and cardiac magnetic resonance (CMR). METHODS: This retrospective CMR study included 11 patients with both AS and AR (BAV-ASR), 30 with AS (BAV-AS), 28 with AR (BAV-AR), 47 with neither AS nor AR (BAV-no_AS/AR), and 40 with trileaflet aortic valve (TAV-no_AS/AR). CMR analysis included the LV end-diastolic volume index (LVEDVi), mass index (LVMi), and extracellular volume fraction (ECV). The Sokolow-Lyon and Cornell products by ECG and TTE-derived E/e' were measured. RESULTS: There were no differences in the ECG, TTE, and CMR parameters between BAV-no_AS/AR and TAV-no_AS/AR. However, the presence of aortic valve dysfunction resulted in an elevated Sokolow-Lyon product for BAV-ASR (p = 0.017) and BAV-AR (p = 0.001), as well as increased Cornell product (p = 0.04) and E/e' (p < 0.001) for BAV-AS compared with BAV-no_AS/AR. LVEDVi and LVMi were elevated in patients with BAV-ASR and BAV-AR compared with those with BAV-no_AS/AR (LVEDVi: 101 ± 29 ml/m2 and 112 ± 32 ml/m2 vs. 74 ± 15 ml/m2, p = 0.005 and p < 0.001, LVMi: 75 ± 7 g/m2 and 64 ± 14 g/m2 vs. 47 ± 9 g/m2, respectively; p < 0.001). There was no difference in ECV between the BAV and TAV-no_AS/AR subgroups. CONCLUSION: Normally functioning BAV did not result in LV remodeling. However, concomitant AV dysfunction was associated with statistically significant morphological remodeling.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Estenosis de la Válvula Mitral , Humanos , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Estudios Retrospectivos , Remodelación Ventricular , Valor Predictivo de las Pruebas , Válvula AórticaRESUMEN
OBJECTIVE: The aim of this study was to test the hypothesis that there are good agreements between cardiac functional and structural indices derived from magnetic resonance imaging (MRI) sequences triggered with pilot tone (PT) and electrocardiogram (ECG). MATERIALS AND METHODS: Sixteen healthy volunteers (11 male, age 21-76 years) underwent a cardiac MRI scan. Cine MRI, T1, and T2 mapping were acquired by using PT and ECG triggering. Quantitative measurements, including left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, longitudinal strain, left ventricular T1 and T2 values, left and right atrial longitudinal strain, and maximal/minimal volumes, were measured. The interclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to evaluate the agreements between measurements derived by MRI sequences triggered with 2 methods. RESULTS: There were no significant differences among end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, left ventricle mass, T1 and T2 values, or longitudinal strains acquired using PT and ECG. There were good agreements and low variations between the levels of these indices acquired with PT and ECG. Interclass correlation coefficients mainly ranged from 0.73 to 0.98. The coefficients of variation ranged from 1.4% to 22.6%. CONCLUSIONS: Pilot tone-triggered MRI provides comparable measurements of cardiac function, motion, and structure as ECG-triggered MRI. Pilot tone has the potential to become a backup of ECG gating in cardiovascular imaging.
Asunto(s)
Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Humanos , Masculino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico , Corazón/diagnóstico por imagenRESUMEN
AIMS: A shorter cardiac rest period within a cardiac cycle is usually thought to be a result of a fast heart rate, and its clinical relevance has long been ignored. The aim of the present study was to test the hypothesis that the length of cardiac rest periods is altered in postcapillary pulmonary hypertension (PH). METHODS AND RESULTS: Twenty-six patients with postcapillary PH and 20 healthy controls were recruited for cardiac magnetic resonance imaging (MRI) scans. All participants had a heart rate no higher than 80 beats/minute. Cine magnetic resonance imaging (MRI, acquired at a four-chamber view) was analyzed to determine the length of cardiac rest periods at end-systole and mid-to-late diastole. PH patients had a shorter rest period at mid-to-late diastole than controls (17.5 ± 8.7% vs. 24.2 ± 4.2%, P = 0.003). Receiver operating characteristic (ROC) curves showed that the proportion of the rest period in diastole (defined as the length of diastasis/diastole) can discriminate PH patients from controls [area under the curve (AUC) = 0.83, 95% confidence interval (CI): 0.71-0.96]. The existence of postcapillary PH was a significant contributor (ß = -5.537, P = 0.023) to shorter cardiac rest periods at mid-to-late diastole after adjusting for potential confounders, including age, sex, heart rate, and blood pressure. CONCLUSIONS: Postcapillary PH is independently associated with shorter cardiac rest periods at mid-to-late diastole. The length of cardiac rest periods has the potential to become a novel quantitative imaging biomarker for indicating cardiovascular health.
Asunto(s)
Hipertensión Pulmonar , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Hipertensión Pulmonar/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Diástole/fisiología , Frecuencia CardíacaRESUMEN
BACKGROUND: Cardiac allograft vasculopathy (CAV) is a complication beyond the first-year post-heart transplantation (HTx). We aimed to test the utility of cardiac magnetic resonance (CMR) to detect functional/structural changes in HTx recipients with CAV. METHODS: Seventy-seven prospectively recruited HTx recipients beyond the first-year post-HTx and 18 healthy controls underwent CMR, including cine imaging of ventricular function and T1- and T2-mapping to assess myocardial tissue changes. Data analysis included quantification of global cardiac function and regional T2, T1 and extracellular volume based on the 16-segment model. International Society for Heart and Lung Transplantation criteria was used to adjudicate CAV grade (0-3) based on coronary angiography. RESULTS: The majority of HTx recipients (73%) presented with CAV (1: n = 42, 2/3: n = 14, 0: n = 21). Global and segmental T2 (49.5 ± 3.4 ms vs 50.6 ± 3.4 ms, p < 0.001;16/16 segments) were significantly elevated in CAV-0 compared to controls. When comparing CAV-2/3 to CAV-1, global and segmental T2 were significantly increased (53.6 ± 3.2 ms vs. 50.6 ± 2.9 ms, p < 0.001; 16/16 segments) and left ventricular ejection fraction was significantly decreased (54 ± 9% vs. 59 ± 9%, p < 0.05). No global, structural, or functional differences were seen between CAV-0 and CAV-1. CONCLUSIONS: Transplanted hearts display functional and structural alteration compared to native hearts, even in those without evidence of macrovasculopathy (CAV-0). In addition, CMR tissue parameters were sensitive to changes in CAV-1 vs. 2/3 (mild vs. moderate/severe). Further studies are warranted to evaluate the diagnostic value of CMR for the detection and classification of CAV.
RESUMEN
BACKGROUND: Large vessel vasculitis (LVV) can be characterized based on symptom severity, and this characterization helps clinicians decide upon treatment approach. Our aim was to compare the imaging findings of combined modality positron emission tomography/magnetic resonance (PET/MR) and inflammatory markers between severe and non-severe LVV. A retrospective query was performed to identify all patients with LVV who underwent PET/MR at our institution between January 2015 and January 2021. RESULTS: Eleven patients (nine females; age 62.2 ± 16.4 years) underwent 15 PET/MR scans. Positivity was defined by findings indicative of active LVV on each modality: PET positive if vessel metabolic activity > liver metabolic activity; MR positive if wall thickening or contrast enhancement. When positive PET or positive MR findings were considered a positive scan, LVV patients with severe disease (n = 9 scans) showed a higher number of positive scans (n = 9) compared to the number of positive scans in non-severe patients (n = 3) (p < 0.05). The sensitivity and specificity for the detection of severe LVV were 1.00 and 0.50, respectively. When only the presence of both positive PET and positive MR findings were considered a positive scan, inflammatory marker levels were not significantly different between severe and non-severe LVV groups (severe: erythrocyte sedimentation rate (ESR) = 9.8 ± 10.6 mm/h; C-reactive protein (CRP) = 0.6 ± 0.4 mg/dL) (non-severe: ESR = 14.3 ± 22.4 mm/h; CRP = 0.5 ± 0.6 mg/dL). Blood- and liver-normalized maximum standardized uptake values were not significantly different between severe and non-severe patients (1.4 ± 0.3 vs 1.5 ± 0.4; 1.1 ± 0.4 vs 1.0 ± 0.3, respectively). CONCLUSIONS: Because of the differences observed, PET/MR appears to be better suited to facilitate the characterization of LVV as severe or non-severe compared to inflammatory marker measurements and quantitative measurements of metabolic activity. Qualitative assessment of PET and MR positivity by 18F-fluorodeoxyglucose PET/MR may be able to supplement clinical symptoms-based LVV classification decisions and may be helpful when clinical symptoms overlap with other disease processes.
RESUMEN
Purpose: The purpose of our study was to assess the value of true lumen and false lumen hemodynamics compared to aortic morphological measurements for predicting adverse-aorta related outcomes (AARO) and aortic growth in patients with type B aortic dissection (TBAD). Materials and Methods: Using an IRB approved protocol, we retrospectively identified patients with descending aorta (DAo) dissection at a large tertiary center. Inclusion criteria includes known TBAD with ≥ 6 months of clinical follow-up after initial presentation for TBAD or after ascending aorta intervention for patients with repaired type A dissection with residual type B aortic dissection (rTAAD). Patients with prior descending aorta intervention were excluded. The FL and TL of each patient were manually segmented from 4D flow MRI data, and 3D parametric maps of aortic hemodynamics were generated. Groups were divided based on (1) presence vs. absence of AARO and (2) growth rate ≥ vs. < 3 mm/year. True and false lumen kinetic energy (KE), stasis, peak velocity (PV), reverse/forward flow (RF/FF), FL to TL KE ratio, as well as index aortic diameter were compared between groups using the Mann-Whitney U or independent t-test. Results: A total of n = 51 patients (age: 58.4 ± 15.0 years, M/F: 31/20) were included for analysis of AARO. This group contained n = 26 patients with TBAD and n = 25 patients with rTAAD. In the overall cohort, AARO patients had larger baseline diameters, lower FL-RF, FL stasis, TL-KE, TL-FF and TL-PV. Among patients with de novo TBAD, those with AAROs had larger baseline diameter, lower FL stasis and TL-PV. In both the overall cohort and in the subgroup of de novo TBAD, subjects with aortic growth ≥ 3mm/year, patients had a higher KE ratio. Conclusion: Our study suggests that 4D flow MRI is a promising tool for TBAD evaluation that can provide information beyond traditional MRA or CTA. 4D flow has the potential to become an integral aspect of TBAD work-up, as hemodynamic assessment may allow earlier identification of at-risk patients who could benefit from earlier intervention.
RESUMEN
Radiologist wellness is important on an individual and group/institutional level and helps to promote a strong and healthy working environment, which can improve radiologist retention and engagement. This paper will discuss case examples of radiologist wellness improvements in a single academic institution over a 3-year period using the DMAIC (Define, Measure, Analyze, Improve, and Control) model. Leveraging this framework led to the implementation of reading room assistants, reduction in work-related injuries by improvements in ergonomics, and the formation of a faculty mentorship program.
Asunto(s)
Radiólogos , HumanosRESUMEN
PURPOSE: The purpose of this study was to determine an optimal saturation-recovery time (TS) for minimizing the underestimation of arterial input function (AIF) in quantitative cardiac perfusion MRI without multiple gadolinium injections per subject. METHODS: We scanned 18 subjects (mean age = 59 ± 14 years, 9/9 males/females) to acquire resting perfusion data and 1 additional subject (age = 38 years, male) to obtain stress-rest perfusion data using a 5-fold accelerated pulse sequence with radial k-space sampling and applied k-space weighted image contrast (KWIC) filters on the same k-space data to retrospectively reconstruct five AIF images with effective TS ranging from 10 to 21.2 ms (2.8 ms steps). Undersampled images were reconstructed using a compressed sensing framework with temporal-total-variation and temporal-principal-component as 2 orthogonal sparsifying transforms. The image processing steps included, same motion correction across five different AIF images, signal normalization by the proton-density-weighted-image, signal-to-T1 conversion using a Bloch equation, T1 -to-gadolinium-concentration conversion assuming fast water exchange, T2 * correction to the AIF, and gadolinium-concentration to myocardial blood flow (MBF) conversion based on a Fermi model. RESULTS: Among five TS values, the shortest TS (10 ms) produced significantly (P < 0.05) higher peak AIF and lower resting MBF (13.73 mM, 0.73 mL g-1 min-1 ) than 12.8 ms (11.24 mM, 0.89 mL g-1 min-1 ), 15.6 ms (9.56 mM, 1.05 mL g-1 min-1 ), 18.4 ms (8.55 mM, 1.17 mL g-1 min-1 ), and 21.2 ms (7.95 mM, 1.27 mL g-1 min-1 ). Similarly, shorter TS reduced underestimation of AIF (or overestimation of MBF) for both during stress and at rest, but this effect was canceled in myocardial-perfusion-reserve (MPR). CONCLUSION: This study demonstrates that TS of 10 ms reduces the underestimation of AIF and, hence, the overestimation of MBF compared with longer TS values (12.8-21.2 ms).
Asunto(s)
Circulación Coronaria , Imagen de Perfusión Miocárdica , Adulto , Anciano , Medios de Contraste , Circulación Coronaria/fisiología , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Perfusión , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
BACKGROUND: Evaluation of aortic stiffness by pulse wave velocity (PWV) across the adult lifespan is needed to better understand normal aging in women and men. PURPOSE: To characterize PWV in the thoracic aorta using 4D flow MRI in an age- and sex-stratified cohort of healthy adults. STUDY TYPE: Retrospective. POPULATION: Ninety nine healthy participants (age: 46 ± 15 [19-79] years, 50% female), divided into young adults (<45 years) (N = 48), midlife (45-65 years) (N = 37), and later life (>65 years) (N = 14) groups. FIELD STRENGTH/SEQUENCE: 1.5 T or 3 T, 2D cine bSSFP, 4D flow MRI. ASSESSMENT: Cardiac functional parameters of end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and myocardial mass were assessed by 2D cine bSSFP. PWV and aortic blood flow velocity were assessed by 4D flow MRI. Reproducibility of PWV was evaluated in a subset of nine participants. STATISTICAL TESTS: Analysis of variance, Pearson's correlation coefficient (r), linear regression, intraclass correlation coefficient (ICC). A P value < 0.05 was considered statistically significant. RESULTS: PWV increased significantly with age (young adults: 5.4 ± 0.9 m/sec, midlife: 7.2 ± 1.1 m/sec, and later life: 9.4 ± 1.8 m/sec) (r = 0.79, slope = 0.09 m/sec/year). PWV did not differ in women and men in entire sample (P = 0.40) or within age groups (young adults: P = 0.83, midlife: P = 0.17, and later life: P = 0.96). PWV was significantly correlated with EDV (r = -0.29), ESV (r = -0.23), SV (r = -0.28), myocardial mass (r = 0.21), and mean aortic blood flow velocity (r = -0.62). In the test-retest subgroup (N = 9), PWV was 6.7 ± 1.5 [4.4-9.3] m/sec and ICC = 0.75. DATA CONCLUSION: 4D flow MRI quantified higher aortic PWV with age, by approximately 1 m/sec per decade, and significant differences between young adults, midlife and later life. Reproducibility analysis showed good test-retest agreement. Increased PWV was associated with decline in cardiac function and reduced aortic blood flow velocity. This study demonstrates the utility of 4D flow MRI-derived aortic PWV for studying aging. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.
Asunto(s)
Análisis de la Onda del Pulso , Rigidez Vascular , Adulto , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Longevidad , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto JovenRESUMEN
BACKGROUND: Gadobutrol (GB) and gadoterate meglumine (GM) are contrast agents used for contrast-enhanced magnetic resonance angiography (CEMRA). Supraaortic vasculature (SAV) CEMRAs are used to evaluate stroke risk and neurologic symptoms. There is a need to compare the SAV CEMRA image quality obtained with GB and GM. PURPOSE: To intra-individually compare MRA images obtained with equimolar GB and GM at 1.5 T in the SAV. STUDY TYPE: Prospective, crossover. POPULATION: Twenty-eight subjects (54 ± 13 years; 17 female). FIELD STRENGTH/SEQUENCE: 1.5 T; three-dimensional (3D) gradient recalled echo. ASSESSMENT: Quantitative image quality was measured by normalized signal intensity (SIn ) [SIn = SI blood/SD blood] and contrast ratio (CR) [CR = SI blood/SI muscle], determined by an observer (JWC) with 1 year of vascular imaging experience. Three radiologists (AS, PA, and MU) with (5, 5, and 6 years of) vascular imaging experience evaluated image quality by Likert-scale ratings (of image impression, wall conspicuity, and artifact absence). STATISTICAL TESTS: SIn and CR were compared with paired t-tests or Wilcoxon signed-rank tests and Bland-Altman plots. Qualitative ratings were compared with Wilcoxon signed-rank test. RESULTS: No significant difference in SIn was found between GB and GM. CRs with GB were significantly higher than GM at the right common carotid (6.9 ± 2.5 vs. 4.8 ± 1), left internal carotid (7.3 ± 2 vs. 4.4 ± 1.2), right internal carotid (7.7 ± 2.2 vs. 5 ± 1.1), and left vertebral (6.6 ± 2.2 vs. 4.5 ± 1.1) arteries. Bland-Altman plots showed relatively greater differences between GB and GM at higher CRs and SIn s. GM showed significantly higher artifact than GB (3.56 ± 0.52 vs. 3.36 ± 0.46) and significantly lower overall image quality (10.73 ± 1.45 vs. 11.26 ± 1.58) at the left vertebral artery. DATA CONCLUSION: At 1.5 T and equimolar demonstration, GB (0.1 mL/kg, i.e., 0.1 mmol/kg) showed higher CRs in the SAV compared to GM (0.2 mL/kg, i.e., 0.1 mmol/kg) at most vessels. Subjective image quality was not significantly different between the two agents for most vessels. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.