Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Radiol ; 78(5): 323-332, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36849280

RESUMEN

Fat necrosis of the breast is a commonly encountered condition in daily practice. It is a benign pathology, but it can have variable manifestations and patterns that may sometimes mimic malignancy, depending on its stage of evolution and its underlying cause. This review demonstrates the wide spectrum of appearances of fat necrosis on mammography, digital breast tomosynthesis (DBT), ultrasound, magnetic resonance imaging (MRI), computed tomography (CT), and positron-emission tomography (PET). Sequential follow-up images are included in some cases to illustrate the temporal change of the findings. The typical location and distribution of fat necrosis from a comprehensive list of aetiologies are discussed. Improved knowledge of the multimodality imaging features of fat necrosis could enhance diagnostic accuracy and clinical management, thus avoiding unnecessary invasive investigations.


Asunto(s)
Neoplasias de la Mama , Necrosis Grasa , Humanos , Femenino , Necrosis Grasa/diagnóstico por imagen , Necrosis Grasa/patología , Mama/diagnóstico por imagen , Mama/patología , Mamografía/métodos , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología
2.
Radiol Case Rep ; 17(10): 3457-3460, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35912290

RESUMEN

We report a rare case of pulmonary mucosa-associated lymphoid tissue lymphoma (MALToma) in a 52-year-old woman presented as cystic lung disease together with ground-glass lesion on computed tomography (CT) of the thorax incidentally found as part of workup for organ donation.

3.
Anaesthesia ; 77(11): 1268-1280, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35947876

RESUMEN

We performed a systematic review and meta-analysis to identify, classify and evaluate the body of evidence on novel wearable and contactless devices that measure heart rate, respiratory rate and oxygen saturations in the clinical setting. We included any studies of hospital inpatients, including sleep study clinics. Eighty-four studies were included in the final review. There were 56 studies of wearable devices and 29 of contactless devices. One study assessed both types of device. A high risk of patient selection and rater bias was present in proportionally more studies assessing contactless devices compared with studies assessing wearable devices (p = 0.023 and p < 0.0001, respectively). There was high but equivalent likelihood of blinding bias between the two types of studies (p = 0.076). Wearable device studies were commercially available devices validated in acute clinical settings by clinical staff and had more real-time data analysis (p = 0.04). Contactless devices were more experimental, and data were analysed post-hoc. Pooled estimates of mean (95%CI) heart rate and respiratory rate bias in wearable devices were 1.25 (-0.31-2.82) beats.min-1 (pooled 95% limits of agreement -9.36-10.08) and 0.68 (0.05-1.32) breaths.min-1 (pooled 95% limits of agreement -5.65-6.85). The pooled estimate for mean (95%CI) heart rate and respiratory rate bias in contactless devices was 2.18 (3.31-7.66) beats.min-1 (pooled limits of agreement -6.71-10.88) and 0.30 (-0.26-0.87) breaths.min-1 (pooled 95% limits of agreement -3.94-4.29). Only two studies of wearable devices measured Sp O2 ; these reported mean measurement biases of 3.54% (limits of agreement -5.65-11.45%) and 2.9% (-7.4-1.7%). Heterogeneity was observed across studies, but absent when devices were grouped by measurement modality and reference standard. We conclude that, while studies of wearable devices were of slightly better quality than contactless devices, in general all studies of novel devices were of low quality, with small (< 100) patient datasets, typically not blinded and often using inappropriate statistical techniques. Both types of devices were statistically equivalent in accuracy and precision, but wearable devices demonstrated less measurement bias and more precision at extreme vital signs. The statistical variability in precision and accuracy between studies is partially explained by differences in reference standards.


Asunto(s)
Frecuencia Respiratoria , Dispositivos Electrónicos Vestibles , Frecuencia Cardíaca , Humanos , Monitoreo Fisiológico/métodos , Oxígeno , Saturación de Oxígeno
4.
Anaesthesia ; 75(12): 1587-1595, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32559315

RESUMEN

The COVID-19 pandemic has led to the production of novel devices intended to protect airway managers during the aerosol-generating procedure of tracheal intubation. Using an in-situ simulation model, we evaluated laryngoscopist exposure of airborne particles sized 0.3 - 5.0 microns using five aerosol containment devices (aerosol box; sealed box with and without suction; vertical drape; and horizontal drape) compared with no aerosol containment device. Nebulised saline was used as the aerosol-generating model for 300 s, at which point, the devices were removed to assess particle spread. Primary outcome was the quantity and size of airborne particles measured at the level of the laryngoscopist's head at 30, 60, 120 and 300 s, as well as 360 s (60 s after device removal). Airborne particles sizes of 0.3, 0.5, 1.0, 2.5 and 5.0 microns were quantified using an electronic airborne particle counter. Compared with no device use, the sealed intubation box with suction resulted in a decrease in 0.3, 0.5, 1.0 and 2.5 micron, but not 5.0 micron, particle exposure over all time-periods (p = 0.003 for all time periods). Compared with no device use, the aerosol box showed an increase in 1.0, 2.5 and 5.0 micron airborne particle exposure at 300 s (p = 0.002, 0.008, 0.002, respectively). Compared with no device use, neither horizontal nor vertical drapes showed any difference in any particle size exposure at any time. Finally, when the patient coughed, use of the aerosol box resulted in a marked increase in airborne particle exposure compared with other devices or no device use. In conclusion, novel devices intended to protect the laryngoscopist require objective testing to ensure they are fit for purpose and do not result in increased airborne particle exposure.


Asunto(s)
Aerosoles , Manejo de la Vía Aérea/métodos , Infecciones por Coronavirus/prevención & control , Infecciones por Coronavirus/transmisión , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Exposición por Inhalación , Intubación Intratraqueal/instrumentación , Intubación Intratraqueal/métodos , Pandemias/prevención & control , Material Particulado , Neumonía Viral/prevención & control , Neumonía Viral/transmisión , COVID-19 , Tos , Humanos , Laringoscopía , Nebulizadores y Vaporizadores , Tamaño de la Partícula , Equipo de Protección Personal , Estudios Prospectivos , Succión
6.
J Evid Inf Soc Work ; 15(6): 599-616, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30142306

RESUMEN

OBJECTIVE: The efficacy of heal-change group (HCG) intervention-brief trauma-recovery group intervention applying a gender-specific cognitive behavioral approach-for Chinese-abused women in refuge centers was examined in a pretest-posttest comparison study. METHODS: A total of 100 women at three refuge centers in Hong Kong participated. Among them, 50 women from two centers joined the HCG and 50 women from the remaining center participated in a comparison mutual support group. Participants and interviewers were blinded to the group assignment. Both groups were six sessions long. Linear regression analyses were performed using the intention-to-treat framework. RESULTS: Significant improvements in PTSD symptoms (overall mean change of -1.6, p < .001; subdomain scores; p < .001 to < .01) and depressive symptoms (BDI-II mean change; p < .01) were recorded in the intervention group. CONCLUSION: The results suggest HCG is beneficial to Chinese-abused women. Further research is needed to determine the intervention's effectiveness in improving longer-term outcomes in these women.


Asunto(s)
Mujeres Maltratadas/psicología , Terapia Cognitivo-Conductual/métodos , Maltrato Conyugal/psicología , Maltrato Conyugal/terapia , Adulto , Anciano , Depresión/psicología , Método Doble Ciego , Femenino , Hong Kong/epidemiología , Humanos , Modelos Lineales , Persona de Mediana Edad , Calidad de Vida , Autoimagen , Grupos de Autoayuda , Factores Socioeconómicos , Trastornos por Estrés Postraumático/psicología
7.
Nat Commun ; 9(1): 1594, 2018 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-29686394

RESUMEN

The nuclear shell structure, which originates in the nearly independent motion of nucleons in an average potential, provides an important guide for our understanding of nuclear structure and the underlying nuclear forces. Its most remarkable fingerprint is the existence of the so-called magic numbers of protons and neutrons associated with extra stability. Although the introduction of a phenomenological spin-orbit (SO) coupling force in 1949 helped in explaining the magic numbers, its origins are still open questions. Here, we present experimental evidence for the smallest SO-originated magic number (subshell closure) at the proton number six in 13-20C obtained from systematic analysis of point-proton distribution radii, electromagnetic transition rates and atomic masses of light nuclei. Performing ab initio calculations on 14,15C, we show that the observed proton distribution radii and subshell closure can be explained by the state-of-the-art nuclear theory with chiral nucleon-nucleon and three-nucleon forces, which are rooted in the quantum chromodynamics.

9.
Phys Rev Lett ; 121(24): 242501, 2018 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-30608744

RESUMEN

The isospin character of p-n pairs at large relative momentum has been observed for the first time in the ^{16}O ground state. A strong population of the J,T=1,0 state and a very weak population of the J,T=0,1 state were observed in the neutron pickup domain of ^{16}O(p,pd) at 392 MeV. This strong isospin dependence at large momentum transfer is not reproduced by the distorted-wave impulse approximation calculations with known spectroscopic amplitudes. The results indicate the presence of high-momentum protons and neutrons induced by the tensor interactions in the ground state of ^{16}O.

10.
Indoor Air ; 28(2): 258-265, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29130534

RESUMEN

One of the most notable Indoor Air Quality problems is odor emission. This study investigated the potential contribution of skin squames to the production of ammonia (NH3 ) and volatile organic acids (VFAs) by 7 bacteria isolated from air-cooling (AC) units with complaints of urine and body odors. Our previous study showed that keratinolytic activity is higher in AC units with odor complaints than those without. In the offices where these units are located, the most likely source of keratins is from human skin squames. Most bacteria can produce NH3 and VFAs in the skin squame culture. Some correlations between the levels of NH3 , NH4+, VFAs, and keratinolytic activity were found. The odor production pathway with skin squames was proposed. Staphylococcus haemolyticus was abundant in the AC units with odor problems and had a high level of keratinolytic activity in addition to odor production. For long-term odor control, it is important to reduce the level of skin squames entering the AC units.


Asunto(s)
Aire Acondicionado , Contaminantes Atmosféricos/análisis , Amoníaco/análisis , Ácidos Grasos Volátiles/análisis , Odorantes/análisis , Piel/química , Recuento de Colonia Microbiana , Monitoreo del Ambiente , Humanos , Piel/microbiología , Staphylococcus haemolyticus/crecimiento & desarrollo
11.
Int J Cardiol ; 220: 299-306, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27390945

RESUMEN

BACKGROUND: Chest pain patients commonly present to emergency departments (ED), and require either hospital admission and/or lengthy diagnostic protocols to rule-out myocardial infarction. We aimed to identify the best combination of add-on tests to high-sensitivity cardiac troponin (hs-cTnT) for predicting 30-day major adverse cardiac events (MACE) in adult chest pain patients presenting to an ED with suspected acute coronary syndrome. METHODS: This prospective observational study was conducted in the ED of a tertiary university hospital in Hong Kong, recruiting adult patients with chest pain of less than 24h duration, suspected with acute coronary syndrome (ACS), and had no history of coronary artery bypass grafting or stent insertion. Patients underwent triage assessment, electrocardiography, blood sampling for laboratory hs-cTnT, and Thrombolysis in Myocardial Infarction (TIMI) and HEART score assessment. The primary outcome was the number of patients with 30-day MACE. RESULTS: 602 consecutive patients were recruited and completed 30-day follow-up. A 30-day MACE occurred in 42 (7.0%) patients. Out of 12 possible models for stratifying patients at risk of 30-day MACE within 2h of ED arrival, a combination of electrocardiography (ECG) and one-time hs-cTnT (model 5) provided the simplest and most accurate model. A risk score of 0 to 5 was derived from raw coefficients of model 5. The risk score provided excellent calibration (P=0.91) and discrimination (AUC 0.87, 95% CI: 0.82 to 0.93). CONCLUSION: Appropriate early risk-stratification of patients with chest pain and possible ACS using a combination of ECG and one-time hs-cTnT may improve efficiency of care.


Asunto(s)
Dolor en el Pecho , Medición de Riesgo/métodos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/epidemiología , Anciano , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Diagnóstico Diferencial , Pruebas Diagnósticas de Rutina/métodos , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Electrocardiografía/métodos , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Hong Kong/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Proyectos de Investigación , Factores de Tiempo , Triaje/métodos
12.
PLoS One ; 10(7): e0129780, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26158447

RESUMEN

The composite metal oxide electrode films were fabricated using ex situ electrodeposition method with further heating treatment at 300°C. The obtained composite metal oxide film had a spherical structure with mass loading from 0.13 to 0.21 mg cm(-2). The structure and elements of the composite was investigated using X-ray diffraction (XRD) and energy dispersive X-ray (EDX). The electrochemical performance of different composite metal oxides was studied by cyclic voltammetry (CV) and galvanostatic charge-discharge (CD). As an active electrode material for a supercapacitor, the Co-Mn composite electrode exhibits a specific capacitance of 285 Fg(-1) at current density of 1.85 Ag(-1) in 0.5 M Na2SO4 electrolyte. The best composite electrode, Co-Mn electrode was then further studied in various electrolytes (i.e., 0.5 M KOH and 0.5 M KOH/0.04 M K3Fe(CN) 6 electrolytes). The pseudocapacitive nature of the material of Co-Mn lead to a high specific capacitance of 2.2 x 10(3) Fg(-1) and an energy density of 309 Whkg(-1) in a 0.5 M KOH/0.04 M K3Fe(CN) 6 electrolyte at a current density of 10 Ag(-1). The specific capacitance retention obtained 67% of its initial value after 750 cycles. The results indicate that the ex situ deposited composite metal oxide nanoparticles have promising potential in future practical applications.


Asunto(s)
Cobalto/química , Técnicas Electroquímicas , Compuestos de Manganeso/química , Óxidos/química , Capacidad Eléctrica , Electrodos , Electrólitos/química , Ferrocianuros/química , Nanopartículas del Metal/química , Nanopartículas del Metal/ultraestructura , Tamaño de la Partícula
13.
J Antimicrob Chemother ; 66(4): 765-8, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21393133

RESUMEN

OBJECTIVES: To assess the occurrence of faecal carriage of Escherichia coli with resistance to 'critically important' antibiotics in various animals. METHODS: Rectal or cloacal swabs were obtained weekly from cattle, pigs, chickens, cats, dogs and wild rodents over a 2 year period. Plain and antibiotic-containing medium was used for bacterial isolation. Selected isolates were characterized by molecular methods. RESULTS: In total, 2106 faecal specimens from 398 cats, 460 chickens, 368 dogs, 210 cattle, 214 pigs and 456 rodents were cultured. The faecal carriage rate of extended-spectrum ß-lactamase (ESBL)-producing E. coli was highest in pigs (63.6%, 136/214) and lowest in rodents (4.2%, 19/456). The faecal ESBL-producing E. coli carriage rate for food-producing animals (53.6%, 474/884) was significantly higher than that for cats/dogs (14.0%, 107/766; P<0.01) and wild rodents (4.2%, 19/456; P<0.01). ESBL-producing isolates from food animals often (33%-81%) had multidrug (≥4) resistance to amikacin, chloramphenicol, ciprofloxacin, co-trimoxazole, gentamicin, nalidixic acid, netilmicin, nitrofurantoin and tetracycline. Most (91.2%) of the ESBL-producing isolates had CTX-M-type enzymes. A total of 10 alleles (3, 13, 14, 15, 24, 27, 28, 55, 65 and 98) from two CTX-M families (M1 and M9) were found. PFGE showed that the CTX-M-producing isolates were genetically diverse. CONCLUSIONS: This study shows that food animals are a major reservoir of E. coli with multidrug resistance to many antibiotics that are ranked as critically important in human medicine.


Asunto(s)
Animales Domésticos/microbiología , Antibacterianos/farmacología , Portador Sano/microbiología , Infecciones por Escherichia coli/microbiología , Escherichia coli/efectos de los fármacos , Escherichia coli/enzimología , beta-Lactamasas/biosíntesis , Animales , Cloaca/microbiología , Farmacorresistencia Bacteriana Múltiple , Escherichia coli/aislamiento & purificación , Hong Kong , Recto/microbiología , Roedores/microbiología
16.
Clin Otolaryngol ; 34(4): 309-15, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19673977

RESUMEN

OBJECTIVES: To establish the reliability and validity of the Chinese (Cantonese) version of the Tinnitus Handicap Inventory to measure the self-perceived handicapping effect and severity of the condition in patients with chronic tinnitus. DESIGN: Cross-sectional psychometric validation study. SETTING: Audiology clinics in a hospital setting. PARTICIPANTS: Subjects were 114 adult Chinese who attended the audiology clinics with a complaint of tinnitus. MAIN OUTCOME MEASURES: Test-retest and internal consistency reliability; construct validity. RESULTS: The Chinese version of the Tinnitus Handicap Inventory and its subscales showed good internal consistency reliabilities (alpha = 0.72-0.94) that are comparable to those of the original version. High correlations were observed between the Tinnitus Handicap Inventory and psychological distress, tinnitus-related problem ratings and severity ratings. Factor analysis showed that the Chinese version of the Tinnitus Handicap Inventory has a unifactorial structure. A high degree of test-retest reliability was observed (intraclass correlation coefficient = 0.88). CONCLUSIONS: The results suggest that the Chinese (Cantonese) version of the Tinnitus Handicap Inventory is a reliable and valid measure of general tinnitus-related distress that can be used in clinical settings to quantify the impact of tinnitus on daily life.


Asunto(s)
Comparación Transcultural , Evaluación de la Discapacidad , Lenguaje , Encuestas y Cuestionarios , Acúfeno/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hong Kong , Humanos , Masculino , Persona de Mediana Edad , Psicometría/estadística & datos numéricos , Reproducibilidad de los Resultados , Acúfeno/clasificación , Acúfeno/psicología , Traducción , Adulto Joven
17.
Int J Bioinform Res Appl ; 5(2): 224-37, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19324607

RESUMEN

In the sequencing process, reads of the sequence are generated, then assembled to form contigs. New technologies can produce reads faster with lower cost and higher coverage. However, these reads are shorter. With errors, short reads make the assembly step more difficult. Chaisson et al. (2004) proposed an algorithm to correct the reads prior to the assembly step. The result is not satisfactory when the error rate is high (e.g., >or=3%). We improve their approach to handle reads of higher error rates. Experimental results show that our approach is much more effective in correcting errors, producing contigs of higher quality.


Asunto(s)
Biología Computacional/métodos , Análisis de Secuencia de ADN/métodos , Algoritmos , ADN/química , Bases de Datos Genéticas , Alineación de Secuencia
18.
Vox Sang ; 83(3): 258-62, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12366770

RESUMEN

BACKGROUND AND OBJECTIVES: The para-Bombay phenotype (also known as H-deficient secretor) is characterized by a lack of ABH antigens on red cells, but ABH substances are found in saliva. Molecular genetic analysis was performed for five Chinese individuals serologically typed as para-Bombay. MATERIALS AND METHODS: ABO genotyping and mutational analysis of both FUT1 (or H) and FUT2 (or Se) loci were performed for these individuals using the polymerase chain reaction, single-strand conformation polymorphism analysis and direct DNA sequencing. RESULTS: The ABO genotypes of these para-Bombay individuals correlated with the types of ABH substances found in the saliva. Their FUT1 genotypes were h1h2 (three individuals), h2h2 (one individual) and h2h6 (one individual). Alleles h1 (547-552delAG) and h2 (880-882delTT) were known frameshift mutations, while h6 (522C > A) was a missense mutation (Phe174Leu) not previously reported. These three mutations were rare sequence variations, each with an allele frequency of less than 0.005. Phe174 might be functionally important because this residue is conserved from mouse to human. Their FUT2 genotypes were Se357se357,385 for the h2h6 individual and Se357Se357) for the others. Both FUT2 alleles were known: one functional (Se357) and one weakly functional (se357,385). That they carried at least one copy of a functional FUT2 allele was consistent with their secretor status. As FUT1 and FUT2 are adjacent on 19q13.3, there are three possible haplotypes in these para-Bombay individuals: h1-Se357; h2-Se357; and h6-se357,385. CONCLUSIONS: A novel non-functional FUT1 allele (522C > A, or Phe174Leu) was identified in a para-Bombay individual and on a se357,385 haplotype background.


Asunto(s)
Sistema del Grupo Sanguíneo ABO/genética , Fucosiltransferasas/genética , Alelos , China , Análisis Mutacional de ADN , Femenino , Mutación del Sistema de Lectura , Fucosiltransferasas/deficiencia , Genotipo , Haplotipos , Humanos , Mutación Missense , Fenotipo , Galactósido 2-alfa-L-Fucosiltransferasa
19.
J Am Chem Soc ; 123(11): 2645-9, 2001 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-11456934

RESUMEN

We report a transient resonance Raman spectrum for the 2-fluorenylnitrenium ion obtained after photolysis of 2-azidofluorene. The 10 experimental Raman band frequencies of the transient spectrum show very good agreement with the computed frequencies from BPW91/cc-PVDZ density functional theory calculations for the 2-fluorenylnitrenium ion. Our results confirm the assignment of the approximately 460 nm transient absorption band formed after photolysis of 2-azidofluorene in water/acetonitrile or water solution to the singlet ground electronic state 2-fluorenylnitrenium ion. Our study indicates the 2-fluorenylnitrenium has a large degree of iminocyclohexadienyl cation character with significant delocalization of the charge over both phenyl rings of the fluorene moiety. We compare our results for the 2-fluoreneylnitrenium ion to those previously reported for several other arylnitrenium ions.

20.
Chemistry ; 7(22): 4928-36, 2001 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-11763461

RESUMEN

We present transient-resonance Raman spectra for the 4-biphenylylnitrenium, diphenylnitrenium, and 2-fluorenylnitrenium ions. These spectra display a number of fundamental vibrational bands whose frequencies exhibit good agreement with those computed using BPW91/cc-PVDZ density functional theory calculations for the singlet ground states of the 4-biphenylylnitrenium, diphenylnitrenium, and 2-fluorenylnitrenium ions. Comparison of these arylnitrenium ions with each other and with previous results for structurally similar biphenyl radical cations indicates that the degree of iminocyclohexadienyl character observed in these arylnitrenium ions depends on the relative orientation of the two phenyl rings, the nature of the nitrenium ion moiety, and the ability of the biphenyl-like group to accommodate positive charge through formation of a more planar-like structure with quinoidal-like character.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA