Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Conserv Dent Endod ; 27(5): 540-544, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939546

RESUMEN

Aim: The aim of this study was to compare the accuracy of two different electronic apex locators (EALs) in detecting simulated incomplete vertical root fractures (VRFs). Materials and Methods: Thirty freshly extracted single-rooted teeth were randomly divided into three groups of 10 teeth each labeled as Groups A, B, and C. Incomplete VRFs were simulated in the coronal, middle, and apical one-third of the roots for Groups A, B, and C, respectively. The teeth were embedded in alginate mold and fracture location was determined with Root ZX and Propex EALs for each sample and each group. To calculate the actual length (AL), each sample was sectioned at the upper level of the vertical fracture, and the length was measured by setting the stopper of the #10 K file under a stereomicroscope at ×30 magnification. The electronic lengths and ALs were compared using computer software, and the results were analyzed using SPSS 28.0 at a 95% confidence level. Results: No significant differences were seen in the accuracy of the two EALs when compared with ALs. Root ZX showed significantly longer measurements than ALs in groups B and C. Conclusion: The tested EALs showed low accuracy (20%) in detecting simulated incomplete VRFs with a tendency for longer measurements compared to ALs.

2.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762747

RESUMEN

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Asunto(s)
Materiales de Impresión Dental , Glutaral , Ensayo de Materiales , Polivinilos , Siloxanos , Materiales de Impresión Dental/química , Polivinilos/química , Siloxanos/química , Factores de Tiempo , Glutaral/química , Desinfectantes Dentales/química , Hipoclorito de Sodio/química , Desinfectantes/química , Clorhexidina/química , Propiedades de Superficie , Humanos
3.
Technol Health Care ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38820026

RESUMEN

BACKGROUND: Any manipulation of the surface of natural teeth may result in a variation of their colour. The fixed orthodontic treatment (FOT) is one such procedure which alters the enamel surface during the procedure. OBJECTIVE: To clinically evaluate the colour changes in teeth associated with comprehensive FOT (to compare the changes in test and control groups) and to determine the relationship of age and gender on enamel colour due to FOT by using an advanced spectrophotometer. METHODS: The selection of sixty patients for the study was done randomly and among these thirty patients who underwent the FOT as the case group, the other thirty patients who did not need FOT, were the control group. The recordings of spectrophotometric data were done in a standardized manner for all patients in the labial circular region of every anterior tooth, following debonding and cleaning operations, and before bracket bonding. The Commission Internationale de l'Eclairage's L*, a*, and b* (lightness, red/green, and blue/yellow) tooth-type characteristics were used to measure color, and the associated color differences (DE) between the groups were computed. One-way ANOVA (a < 0.05) and the paired t-test were used to evaluate any changes in these color characteristics. RESULTS: Fixed orthodontic treatment is associated with changes in colour parameters. L* values decreased (P< 0.001), while a* and b* values increased (P< 0.001) at the end of treatment. All measured tooth types showed significant colour change (DE); their mean differences ranged from 1.64 to 2.96 DE units. CONCLUSIONS: Fixed orthodontics can change the natural colour of teeth. The CIE colour parameters L*, a*, and b* of natural teeth showed statistically significant differences after debonding the orthodontic appliances. The L* values decreased making the teeth look darker. The adolescent and male patients had more tooth colour changes than the adult and female groups.

4.
Eur J Med Res ; 29(1): 254, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659074

RESUMEN

BACKGROUND: Yttrium-stabilized zirconia (YSZ) and alumina are the most commonly used dental esthetic crown materials. This study aimed to provide detailed information on the comparison between yttrium-stabilized zirconia (YSZ) and alumina, the two materials most often used for esthetic crowns in dentistry. METHODOLOGY: The ground-state energy of the materials was calculated using the Cambridge Serial Total Energy Package (CASTEP) code, which employs a first-principles method based on density functional theory (DFT). The electronic exchange-correlation energy was evaluated using the generalized gradient approximation (GGA) within the Perdew (Burke) Ernzerhof scheme. RESULTS: Optimization of the geometries and investigation of the optical properties, dynamic stability, band structures, refractive indices, and mechanical properties of these materials contribute to a holistic understanding of these materials. Geometric optimization of YSZ provides important insights into its dynamic stability based on observations of its crystal structure and polyhedral geometry, which show stable configurations. Alumina exhibits a distinctive charge, kinetic, and potential (CKP) geometry, which contributes to its interesting structural framework and molecular-level stability. The optical properties of alumina were evaluated using pseudo-atomic computations, demonstrating its responsiveness to external stimuli. The refractive indices, reflectance, and dielectric functions indicate that the transmission of light by alumina depends on numerous factors that are essential for the optical performance of alumina as a material for esthetic crowns. The band structures of both the materials were explored, and the band gap of alumina was determined to be 5.853 eV. In addition, the band structure describes electronic transitions that influence the conductivity and optical properties of a material. The stability of alumina can be deduced from its bandgap, an essential property that determines its use as a dental material. Refractive indices are vital optical properties of esthetic crown materials. Therefore, the ability to understand their refractive-index graphs explains their transparency and color distortion through how the material responds to light..The regulated absorption characteristics exhibited by YSZ render it a highly attractive option for the development of esthetic crowns, as it guarantees minimal color distortion. CONCLUSION: The acceptability of materials for esthetic crowns is strongly determined by mechanical properties such as elastic stiffness constants, Young's modulus, and shear modulus. YSZ is a highly durable material for dental applications, owing to its superior mechanical strength.


Asunto(s)
Óxido de Aluminio , Coronas , Itrio , Circonio , Itrio/química , Circonio/química , Óxido de Aluminio/química , Humanos , Teoría Cuántica
5.
J Pers Med ; 14(2)2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38392606

RESUMEN

BACKGROUND: Minimally invasive periodontic (perio) surgical procedures, piezocision, and micro-osteoperforation are useful techniques for accelerating tooth movement. These techniques also offer advantages in the orthodontic (ortho) and aesthetic domains. This study aimed to evaluate and compare the rates of lower anterior decrowding with piezocision and micro-osteoperforation. METHODS: This clinical study included 24 patients requiring fixed orthodontic treatments. Two periodontic techniques (piezocision (PZ) and micro-osteoperforation (MOP)) were considered for the orthodontic treatments. Each patient was randomly allocated to either the piezocision (PZ) group or the micro-osteoperforation (MOP) group. The piezocision group received five radiographically guided incisions on the labial surface of the alveolar bone, whereas the micro-osteoperforation group received one to three MOPs each using a mini-implant drill between the six lower anterior teeth, and later, an initial arch wire was ligated to each bracket. Little's irregularity index (LII) was calculated using a digital vernier caliper on study models every four weeks until decrowding was achieved. The difference in the rates of lower anterior crowding between the piezocision and micro-osteoperforation groups was analyzed to determine the statistical significance. RESULTS: The rates of irregularity index change during decrowding were 4.38 ± 0.61 in the piezocision group and 3.82 ± 0.47 in the micro-osteoperforation group. Piezocision was found to be 1.2 times faster than micro-osteoperforation in terms of the rate of decrowding. CONCLUSION: The advanced perio-ortho combination technique was advantageous in accelerated decrowding. In comparison to MOP, there was an increase in the rate of decrowding with PZ. Decrowding can be completed quickly with PZ, and it can thus be used to treat crowding effectively in a limited time frame.

6.
BMC Oral Health ; 24(1): 41, 2024 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191372

RESUMEN

BACKGROUND: Periodontal phenotype is regarded to be one of the key factors influencing the efficacy of restorative therapies in dental practice. The objective of the systematic review was to explore the importance of thin and thick periodontal phenotypes and how they affect the outcome of periodontal and restorative therapies by looking at a number of academic publications from various online databases. METHODS: Following the PRISMA guidelines (Preferred Reporting Items for Systematic Review standards), relevant data will be searched and retrieved from three significant scientific databases, including PubMed, EBSCO, and Scopus. The articles with full texts that matched the keywords and published in English between 2018 and 2023 were taken into consideration. RESULTS: The majorities of these articles were based on the type of periodontal phenotype and their impact on periodontal and restorative treatment outcomes were selected. The initial search yielded a total of 530 articles. Only 273 were relevant to the review's objectives, and these were considered for determining eligibility. Only 20 publications were eligible for analysis. CONCLUSION: Understanding these anatomical aspects of periodontal phenotype is crucial to both periodontology and restorative dentistry. The clinical outcome of restorative, prosthetic, orthodontic, surgical, and periodontal therapies is determined in large part by the periodontal phenotype, which also plays a significant role in clinical failure or success in dental treatments. TRIAL REGISTRATION: This study protocol registered with the International Prospective Register of Systematic Reviews (PROSPERO) dated 16th June 2023 with the registration ID CRD42023432568.


Asunto(s)
Atención Odontológica , Periodoncia , Humanos , Bases de Datos Factuales , Fenotipo
7.
Technol Health Care ; 32(2): 1055-1065, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37483039

RESUMEN

BACKGROUND: Phonetics with mechanics and aesthetics are considered cardinal factors contributing to the success of complete dentures. OBJECTIVE: The aim of the current study was to evaluate the changes in speech in complete denture patients with and without palatal surface changes. METHODS: The data collected for the study involved completely edentulous Patients (n= 80). Patients were divided into two groups. Group A: Up to 50 years (n= 40); Group B: Above 50 years (n= 40) (including male and female). Each group was further divided into four subgroups for speech analysis-without dentures (A1/B1); with conventional dentures (A2/B2); dentures with a palatogram (A3/B3) and dentures with palate sandblasted (A4/B4). The speech sounds of all patients were evaluated for pitch and intensity using a spectrophotogram (Praat software) and Likert scale. The data so obtained from the quantitative and qualitative analysis were statistically analysed through one-way ANOVA, unpaired student's t-test, and Pearson correlation coefficient. Qualitative analysis was done with the Mann-Whitney U test. RESULTS: The maximum mean value of the pitch and intensity in Groups A and B was subgroup A3 (Palatogram) 190.37 ± 21.50 and 77.07 ± 7.58, B3 (Palatogram) 190.87 ± 24.36 and 75.33 ± 8.12. When comparing Groups A [A1, A2, A3, A4] and B [B1, B2, B3, B4] on the basis of pitch and intensity, a statistically insignificant value was found. No changes in speech sounds (pitch and intensity) were observed in terms of age. Both quantitative and qualitative analysis results showed that speech sounds in the patients with palatogram, had the highest pitch and intensity and were most clear to the listener and there were statistically significant differences from other groups. CONCLUSION: Speech was better in palatogram-based dentures in comparison to a sandblasted denture, conventional denture and without denture in terms of qualitative and quantitative analysis. The physiologic nature of the palatogram fabrication technique produces the palatal part of the denture more compatible with the tongue, thus producing better speech.


Asunto(s)
Boca Edéntula , Habla , Humanos , Masculino , Femenino , Habla/fisiología , Dentadura Completa , Hueso Paladar , Fonética
8.
Technol Health Care ; 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37980583

RESUMEN

BACKGROUND: Bonding between metal and ceramic is one of the most important aspects of a successful prosthesis. Various methods have been recommended for preparing the metal surface to enhance the bond between metal and ceramic including the use of a metal bonding agent. OBJECTIVE: This study aims to evaluate and compare the shear bond strength of the metal-ceramic (M-C) interface after combinations of various surface treatments including the application of a metal bonding agent. METHOD: 40 Ni-Cr alloy specimens were made and divided into 4 groups of 10 each based on the combination of surface treatments. Sandblasting, surface grinding, and Oxidation heat treatment (OHT) were performed on specimens from Group 1 (Control). In addition, Group 2 specimens received ultrasonic cleaning, Group 3 steam cleaning, and Group 4 metal bonding agent application. Following surface treatments on all specimens, porcelain build-up was performed, and shear bond strength was tested in a Digital Universal testing machine. The statistical tests used were independent t-test and ANOVA. RESULTS: Results revealed that Group 4 specimens had the highest mean value of shear bond strength of 39.087 MPa while Group 3 specimens showed the least mean shear bond strength of 18.154 MPa with highly statistically significant results (p< 0.001). CONCLUSION: The surface treatments and application of bonding agent to metal prior to porcelain application resulted in increased shear bond strength of the metal-ceramic interface.

9.
Metabolomics ; 19(11): 92, 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37940751

RESUMEN

BACKGROUND: Pulmonary sarcoidosis (SAR) and tuberculosis (TB) are two granulomatous lung-diseases and often pose a diagnostic challenge to a treating physicians. OBJECTIVE: The present study aims to explore the diagnostic potential of NMR based serum metabolomics approach to differentiate SAR from TB. MATERIALS AND METHOD: The blood samples were obtained from three study groups: SAR (N = 35), TB (N = 28) and healthy normal subjects (NC, N = 56) and their serum metabolic profiles were measured using 1D 1H CPMG (Carr-Purcell-Meiboom-Gill) NMR spectra recorded at 800 MHz NMR spectrometer. The quantitative metabolic profiles were compared employing a combination of univariate and multivariate statistical analysis methods and evaluated for their diagnostic potential using receiver operating characteristic (ROC) curve analysis. RESULTS: Compared to SAR, the sera of TB patients were characterized by (a) elevated levels of lactate, acetate, 3-hydroxybutyrate (3HB), glutamate and succinate (b) decreased levels of glucose, citrate, pyruvate, glutamine, and several lipid and membrane metabolites (such as very-low/low density lipoproteins (VLDL/LDL), polyunsaturated fatty acids, etc.). CONCLUSION: The metabolic disturbances not only found to be well in concordance with various previous reports, these further demonstrated very high sensitivity and specificity to distinguish SAR from TB patients suggesting serum metabolomics analysis can serve as surrogate method in the diagnosis and clinical management of SAR.


Asunto(s)
Sarcoidosis , Tuberculosis , Humanos , Metabolómica/métodos , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Magnética , Sarcoidosis/diagnóstico
10.
J Appl Biomater Funct Mater ; 21: 22808000231198807, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38018370

RESUMEN

Materials like carbamide peroxide or hydrogen peroxide are commonly used for vital teeth bleaching. However, there have been concerns regarding their effect on composite-to-bleached enamel bonding strength. The study investigated the impact of organic and antioxidant agents on composite bond strength in bleached enamel with different dental adhesive solvents. Human third molar teeth were sectioned into buccal and lingual halves. The two main adhesive solvent groups evaluated were acetone and alcohol. Each main group was divided into six groups. The positive control group received no bleaching, the negative control group consisted of bleaching with no surface deoxidization; and other experimental categories involved post-bleach treatments with 95% ethanol, sodium ascorbate (10%), acetone solution, or sodium fluoride solution (1.1%). Following the surface treatment and enamel bonding procedure, nano-hybrid composite cylinders measuring 3 × 2 mm were directly cured over the bleached enamel substrate. The shear bond test was performed after 24-h storage and 12,000 thermocycles on a universal testing machine. In this study, one-way ANOVA was used along with Tukey's HSD tests at a significance level of 0.05. The negative control groups showed significantly lower bond strength than the positive control group. Ethanol surface treatment had superior mean bonding strength in acetone and alcohol-based adhesive solvent groups. The utilization of sodium ascorbate for surface treatment resulted in a significant enhancement of adhesion between the composite material and bleached enamel surface. Sodium fluoride application showed no significant recovery in shear bond strength in both dental adhesive groups. It was concluded that hydrogen peroxide severely compromised the immediate bond strength of composite resin. Surface treatment of bleached enamel with ethanol, sodium ascorbate, and acetone solutions is an effective option for restoring bond strength.


Asunto(s)
Recubrimiento Dental Adhesivo , Blanqueamiento de Dientes , Humanos , Antioxidantes/farmacología , Peróxido de Hidrógeno/química , Solventes , Acetona , Fluoruro de Sodio , Blanqueamiento de Dientes/métodos , Ácido Ascórbico , Resinas Compuestas/química , Etanol , Cementos Dentales , Esmalte Dental , Resistencia al Corte , Urea
11.
BMC Oral Health ; 23(1): 844, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37940890

RESUMEN

BACKGROUND: This study aimed to determine the relative positioning accuracy of multiple implants utilizing four distinct types of splinting materials. METHODS: The purpose of this in-vitro study was to compare the precision of four splinting materials in an open tray impression technique in multiple implant situations. Based on the material used for splinting, four groups were made (n = 40)- Group A: Conventional Method, Group B: Prefabricated Pattern Resin Framework, Group C: Prefabricated Metal Framework, Group D: Light Cured Pattern Resin, these groups were compared with the master model. A heat-cured clear acrylic resin and a master model were constructed. A pilot milling machine drill was used to drill four parallel holes in the anterior and premolar regions, which were later labeled as A, B, C, and D positions from right to left. Then, sequential drilling was carried out, and four 3.75­mm diameter and 13-mm long ADIN implant analogs with internal hex were placed in the acrylic model using a surveyor for proper orientation. The impression posts were then manually screwed to the implant analogs using an open tray, and they were secured to the implants using 10 mm flat head guide pins with a 15 N.cm torque. 10 Open tray polyether impressions were made, and casts were poured. Each splinting method's distortion values were measured using a coordinate measuring machine capable of recordings in the X-, Y-, and Z-axes. Comparison of mean distances for X1, X2, and X3 was made using the Kruskal-Wallis test, and Pairwise comparison was done using Post Hoc Tukey's Test. RESULTS: The differences between the groups were significant when assessing the distances X1, X2, and X3 (p < 0.05). The comparison of deviations between the groups revealed a statistically significant difference (p < 0.05) for the deviation distance X3 but not for the deviation distances X1 and X2. For distance Y1, the difference between the groups was statistically significant (p0.05), but it was not significant for distances Y2 and Y3. A statistically significant difference was seen in the comparison between the groups (p < 0.05) for the deviation distances Y1, Y2, and Y3. The results were statistically significant for the distance Z1 comparisons, namely, control vs. Group A (p = 0.012), control vs. Group B (p = 0.049), control vs. Group C (p = 0.048), and control vs. Group D (p = 0.021), and for distance Z3 comparison for control vs. Group A (p = 0.033). The results were statistically insignificant for the distance Z2 comparisons (p > 0.05). CONCLUSIONS: All splinting materials produced master casts with measurements in close proximity to the reference model. However, prefabricated pattern resin bars splinting showed the highest accuracy among the studied techniques. The most recent splinting techniques using prefabricated metal framework and light-cure pattern resin showed similar accuracy.


Asunto(s)
Implantes Dentales , Humanos , Técnica de Impresión Dental , Materiales de Impresión Dental , Modelos Dentales , Resinas Acrílicas
12.
Sci Rep ; 13(1): 16673, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37794022

RESUMEN

Reusing of alloy has become a need of time due to the increasing demand, depletion of resources, and substantial increase in their price. The alloys used require a long-term stay in the oral cavity exposed to a wet environment, so they must have good wear resistance, biocompatibility, and mechanically good strength. In this study, the vertical marginal discrepancy, surface roughness, and microhardness of the new and recast nickel-chromium (base metal) alloys were evaluated. 125 wax patterns were fabricated from a customized stainless steel master die with a heavy chamfer cervical margin divided into 5 groups. Each group had 25 samples. Group A: 25 wax patterns were cast using 100% by weight of new alloy, Group B: the casting was done by using 75% new alloy and 25% alloy by weight, Group C: wax patterns were cast using 50% new alloy and 50% alloy, Group D: 25% new alloy and 75% alloy and Group E: 100% recast alloy. The vertical marginal discrepancy was measured by an analytical scanning microscope, microhardness was tested on a universal testing machine, and surface roughness was on a tester of surface roughness. Castings produced using new alloys were better than those obtained with reused alloys. Alloys can be reused till 50% by weight along with the new alloy and accelerated casting technique can be used to save the lab time to fabricate castings with acceptable vertical marginal discrepancy, microhardness, and surface roughness. This indicated that 50% recasting of (Ni-Cr) can be used as a good alternative for the new alloy from an economical point of view.

13.
Medicine (Baltimore) ; 102(43): e35528, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37904410

RESUMEN

Occupational burnout is a chronic psychological problem affecting professionals. The aim of this study was to assess the types and categories of burnout among Saudi Dental board residents at different levels of residency in different provinces of Saudi Arabia, using the Copenhagen Burnout Inventory. Questionnaires were sent to 170 Saudi Dental board residents via Email and WhatsApp. at various training centers in Saudi Arabia, in May 2022. A part of the questionnaire covered the socio-demographic characteristics of the participants such as gender, training level or center, number of working sessions or hours per week and day, dental speciality, and marital status. The second part consisted of the Copenhagen Burnout Inventory survey with 21 questions. Only 110 participants returned the answered questions. The overall significant type of burnout was present in 46.3% of the respondents while 53.7%, were for free or minimal burnout. Personal, work-related, and patient-related burnout recorded 62%/38%; 40% to 60%, and 60%:40% for free or minimal to significant burnout. The overall burnout types of values were equal in both gender as well as training levels with no significant differences and P-values ≤ .05. Burnout values were close to each other among the participants in different specialties, except for orthodontics residents which were the least. Analysis of variance, followed by chi-square tests showed a significant difference among participants in different specialties in type and categories of burnout with P-values between .002 to .029. Finally, the burnout value was higher among married participants. Overall burnout types were marginally similar between genders and training levels, while the significant was slightly higher in females, married, highest training level, restorative, and prosthodontic speciality participants.


Asunto(s)
Agotamiento Profesional , Internado y Residencia , Humanos , Masculino , Femenino , Agotamiento Profesional/epidemiología , Agotamiento Profesional/psicología , Estudios Transversales , Prevalencia , Arabia Saudita/epidemiología , Encuestas y Cuestionarios , Factores de Riesgo
14.
Saudi Dent J ; 35(6): 684-691, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37817790

RESUMEN

Digitalized workflow eliminates the need for the tray, impression materials, its decontamination, packaging and shipping, pouring with plaster, cast fabrication, mounting in an articulator, reducing storage spaces, and the risks of any loss or fracture of the plaster model is overcome by archiving on the computer. This clinical investigation aimed to evaluate the effectiveness of the fully digitalized rehabilitation [implant-supported prosthesis] method in partially edentulous patients and with TMD, using advanced software. Twelve patients requiring implant-supported prosthesis in the mandibular molar area with Temporomandibular disorders [TMD] were selected. The fully digitalized rehabilitation method with advanced software was used for rehabilitation. For each subject, Optical impressions, CBCT scan, and Digital recording of jaw movement data. Guided implant surgery and digitalized prosthetic rehabilitation; were performed. The effectiveness of the digitalized workflow was assessed by evaluating the changes in the joint symptoms before and after the end of the treatment, changes in the electromyographic tracings, the precision of the prosthetic artefact, assessed through the amount of chair adjustment operating time and the number of retouching/ modifications to be carried out before the completion of the work. The results showed that the mean operative time required in 12 patients was 9.42 min, significantly less than the time recorded in previous studies when the medium mean was 16.00 min. The mean number of touch-ups [adjustments] was less than 3, most of which were on the interproximal surfaces. There were no significant changes recorded in the electromyography tracings. There were also no changes in joint symptoms. It was found that this way of working was entirely reliable and significantly reduced operating times and the number of appointments. Digital flow is beneficial ei dysfunctional patients, not about improvements in temporomandibular symptoms but in times of operability and prosthetic retouching.

15.
J Clin Med ; 12(18)2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37762774

RESUMEN

BACKGROUND: At present, the evidence regarding digital impressions' accuracy recorded by using digital scanners is lacking. This systematic review aimed to evaluate whether the type of scanning (intraoral/extraoral) affects the Accuracy of Digital Impressions. METHOD: Two independent reviewers performed a systematic search in the database both electronically and manually (PubMed, Ebsco HOST, the Cochrane Library, and Google Scholar) for articles published from 1 January 2010 to 1 December 2022. This study was registered with the International Prospective Register of Systematic Reviews (PROSPERO CRD42020188765) and followed the PRISMA statement. The question in focus was as follows: Does the type of scanning (intraoral or extraoral) affect the accuracy of digital impression? RESULTS: A total of 449 papers were obtained by searching electronically and manually. In total, 15 complete-text papers qualified for assessment based on eligibility criteria. After reading the full-text articles, five studies were excluded. Ten studies were selected for the qualitative analysis. The qualitative data reported that the accuracy of both types of scanners (intraoral and extraoral) lies within the range of clinical acceptability. Nevertheless, the intraoral scanners seem to be more accurate when compared to the extraoral scanners for a partial arch situation. CONCLUSIONS: Scanning type affects the accuracy of the digital impression. Various factors influence the scanning ability. Intraoral scanners seem to be more accurate compared to extraoral scanners for a partial arch situation. More studies comparing the accuracy of the intraoral scanner and extraoral scanner for a complete arch scan and in an in vivo study setting are needed.

16.
BMC Oral Health ; 23(1): 564, 2023 08 13.
Artículo en Inglés | MEDLINE | ID: mdl-37574557

RESUMEN

BACKGROUND: Developing efficient bonding techniques for orthodontic brackets and all-ceramic materials continues to pose a clinical difficulty. This study aimed to evaluate the shear bond strengths (SBS) of metal and ceramic brackets to various all-ceramic CAD-CAM materials, such as lithium disilicate CAD (LDS-CAD), polymer-infiltrated ceramic (PIC), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia after different surface treatments and thermal cycling. MATERIALS AND METHODS: The samples were divided into two groups to be bonded with ceramic and metal lower incisor brackets. Each group was subdivided into a control group devoid of any surface treatment, 10% HF acid (HFA) etching, ceramic etch & prime (MEP), Al2O3 air abrasion, and medium grit diamond bur roughening. After surface treatment, brackets were bonded with composite resin cement, thermal cycled, and tested for shear bond strength. The failed surfaces were evaluated with a digital microscope to analyse the type of failure. The data were statistically analysed using a one-way ANOVA and Tukey HSD tests at p < 0.05. RESULTS: The highest mean bond strengths were found with HFA etching in LDS-CAD (13.17 ± 0.26 MPa) and ZLS (12.85 0.52 MPa). Diamond bur recorded the lowest mean bond strength roughening across all the ceramic groups. There were significant differences in mean shear bond values per surface treatment (p < 0.001) and ceramic materials. CONCLUSION: Among the surface treatment protocols evaluated, HFA etching and MEP surface treatment resulted in enhanced bond strength of both ceramic and metal brackets to CAD-CAM all ceramic materials.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Humanos , Abrasión Dental por Aire , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Cerámica/química , Cementos de Resina/química , Diseño Asistido por Computadora , Diamante , Ensayo de Materiales , Resistencia al Corte
17.
Gels ; 9(6)2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37367153

RESUMEN

BACKGROUND: Propolis is a natural resinous substance collected by honeybees, chiefly from buds and the leaves, branches, and bark of trees. Its role as a wound-healing gel has been studied, but the use of a propolis hydrogel in the treatment of dentinal hypersensitivity has not been evaluated. Dentin hypersensitivity (DH) is commonly treated via iontophoresis using fluoridated desensitizers. The aim of the present study was to compare and evaluate the effects of a 10% propolis hydrogel, 2% sodium fluoride (NaF), and 1.23% acidulated phosphate fluoride (APF) when used in conjunction with iontophoresis for the treatment of cervical dentin hypersensitivity (DH). METHODS: Systemically healthy patients complaining of DH were selected for this single-centre, parallel, double-blind randomized clinical trial. Three substances were selected as desensitizers for study in the present trial: a 10% propolis hydrogel, 2% sodium fluoride, and 1.23% acidulated phosphate fluoride, all in conjunction with iontophoresis. Any decrease in DH following the application of specific stimuli was assessed at baseline, before and after application, on the 14th day following use, and on the 28th day following the intervention. RESULTS: Intra-group comparisons show diminished values of DH at maximum post-op follow-up intervals which were significantly trimmed down from the baseline (p < 0.05). The 2% NaF demonstrated a significant reduction in DH over 1.23% APF and the 10% propolis hydrogel (p < 0.05). However, there was no statistically significant difference in the mean difference between the APF and propolis hydrogel groups assessed via tactile, cold, and air tests (p > 0.05). CONCLUSION: All three desensitizers have proved to be useful when used in conjugation with iontophoresis. Within the limitations of this study, a 10% propolis hydrogel can be used as a naturally occurring alternative to commercially available fluoridated desensitizers.

18.
Technol Health Care ; 31(5): 1957-1968, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37125592

RESUMEN

BACKGROUND: Cone-beam computed tomography (CBCT) could be more beneficial in clinical situations that involve the determination of root canal morphology. AIM: The aim of the study was to ascertain the prevalence of radix molaris (paramolaris-RP and entomolaris-RE) in a subpopulation of Saudi Arabia using CBCT. METHOD: A total of 700 CBCT scans of mandibular permanent first molars were included in this study. All CBCT scans were interpreted by two trained dentists and an endodontist. Mandibular permanent first molars with fully developed roots and closed apices were only included. Computed Tomography scans were obtained from the dental college record. The anatomic characteristics which were checked included: the prevalence of radix molaris in both RE and RP and the prevalence of radix molaris according to the patient's gender and age. All CBCT images were processed and reconstructed using OnDemand3DTM imaging software. RESULTS: Of the 700 patients included, 651 (93.0%) did not have radix molaris, 46 (6.6%) had radix entomolaris and 3 (0.4%) had radix paramolaris in the study group. There was no statistically significant difference between the genders and age in the incidence of RE and RP (P-value < 0.05). CONCLUSION: The study showed that RE prevalence is more compared to RP in the first lower molars in the population studied. It is important to identify extra roots and associated canals to perform successful root canal treatment and avoid failure.


Asunto(s)
Diente Molar , Raíz del Diente , Humanos , Masculino , Femenino , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen , Mandíbula/anatomía & histología
19.
J Oral Maxillofac Pathol ; 27(1): 220-223, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37234311

RESUMEN

A case report of the clinical features and follow-up of an unusual case of a three-day-old baby boy with bilateral protrusion of the buccal pad of fat into the oral cavity. A follow-up of two years is also presented here. No history of trauma was reported. The swellings gradually decreased in size and finally disappeared by the age of 22 months. Hence, the clinician should be aware about this self-limiting and self-disappearing developmental anomaly.

20.
J Pers Med ; 13(3)2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36983736

RESUMEN

The COVID-19 crisis demanded that all educational activities should be performed virtually to follow social distancing guidelines. Therefore, there was a need to perform a research study to assess the effects of external factors on the perceived usefulness, ease of use of e-learning, and the further effect of these perceptions on attitude and intent to use e-learning by using the technology acceptance model (TAM) among academicians at higher education institutions in the Kingdom of Saudi Arabia. METHODS: A cross-sectional study was conducted, and data were collected from 263 academicians across Saudi Arabia through an online survey questionnaire using a non-probability purposive sampling technique and analyzed and tested using the SPSS and Smart PLS software. RESULTS: This study found that self-efficacy was positively associated with perceived usefulness at ß = 0.143 and p < 0.05, but it had no association with perceived ease of use at ß = 0.057 at p > 0.05. System accessibility had a significant and positive relationship with perceived usefulness and perceived ease of use at ß = 0.283, ß = 0.247, and p < 0.01, respectively. Self-efficacy had a positive effect on perceived usefulness, whereas the subjective norm had no relationship with perceived usefulness and perceived ease of use at ß = -0.065 and ß = -0.012 at p > 0.05, respectively. Perceived ease of use and perceived usefulness were positively related to attitude towards use, which has a significant influence on intention to use e-learning. CONCLUSION: Perceived ease of application is the most significant factor (ß = 0.556) in developing the attitude among academicians to practice e-learning, followed by perceived usefulness (ß = 0.262). Moreover, it can be concluded that system accessibility has a stronger influence on developing perception among academicians about the expediency and ease of application of e-learning than self-efficacy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA