1.
Endosc Int Open ; 7(4): E412-E420, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30931371

RESUMEN

Background and study aims Flexible endoscopes are potential vectors of pathogen transmission to patients that are subjected to cleaning and high-level disinfection after each procedure. Efficient manual cleaning is a prerequisite for effective high-level disinfection. The goal of this study was to demonstrate the impact of the cleaning chemistry in the outcome of the manual cleaning of endoscopes. Materials and methods Twelve endoscopes were included in this study: four colonoscopes, four gastroscopes, two duodenoscopes and two bronchoscopes. This study was designed with two phases; in each of them, the manual cleaning procedure remained identical, but a different detergent was used: a non-enzymatic detergent-disinfectant (NEDD) and an enzymatic detergent (ED). Biopsy and suction channels of endoscopes were sampled using 10 mL of physiological saline at two points: before and after manual cleaning, and adenosine triphosphate (ATP) was measured on each sample. In total, 208 procedures were analyzed for the NEDD phase and 253 for the ED phase. Results For each endoscope type, cleaning endoscopes with ED resulted in larger median decrease in ATP than with NEDD: respectively 99.43 % and 95.95 % for bronchoscopes ( P  = 0.0007), 99.28 % and 96.93 % for colonoscopes ( P  < 0.0001) and 98.36 % and 95.36 % for gastroscopes ( P  < 0.0001). In addition, acceptability rates of endoscopes based on defined post-manual cleaning ATP thresholds (200, 150, 100 or 50 relative light units) for all endoscope types were significantly higher with ED compared to NEDD. Conclusions With all other parameters of manual cleaning remaining unchanged, the enzymatic chemistry of ED provided more consistent and improved cleaning of endoscopes compared to NEDD. Therefore, choice of the detergent for endoscope cleaning has an impact on the outcome of this process.

2.
Med Mycol ; 48(7): 969-74, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20199171

RESUMEN

A study was carried out over a 4-month winter period in order to assess the presence of filamentous fungi in the water distribution system of the University Hospital of Liège. A total of 197 hot and cold water samples were collected from the main water supply lines and from the taps at three different hospital sites. Overall, filamentous fungi were recovered from 55% and 50% of the main water distribution system and tap water samples, respectively, with a mean of 3.5 ± 1.5 colony forming units per 500 ml water. Nine different genera were identified, all belonging to the Hyphomycetes class. Aspergillus spp. were recovered from 6% of the samples of the water distribution system and A. fumigatus was the most frequently recovered species (66.6%). However, this species was not isolated from water taps. Fusarium spp. was predominant at one site, where it was found in 28% of tap water samples. No Aspergillus spp. but some Fusarium spp. isolates were identified in samples collected from high-risk units. Filters were introduced at the point-of-use in the haematology unit after completion of the study. The findings of the present study confirm the need for further documented studies to evaluate the safety of the hospital water system and to define new preventive measures.


Asunto(s)
Hongos/aislamiento & purificación , Hospitales Universitarios , Micosis/epidemiología , Microbiología del Agua , Abastecimiento de Agua/análisis , Aspergillus/aislamiento & purificación , Bélgica/epidemiología , Recuento de Colonia Microbiana , Infección Hospitalaria/epidemiología , Infección Hospitalaria/prevención & control , Hongos/clasificación , Fusarium/aislamiento & purificación , Humanos , Micosis/prevención & control , Factores de Riesgo