Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int J Obstet Anesth ; 60: 104245, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39236438

RESUMEN

BACKGROUND: Video-laryngoscopy is increasingly used during general anesthesia for emergency cesarean deliveries. Given the heightened risk of difficult tracheal intubation in obstetrics, addressing challenges in airway management is crucial. In this simulation study, we hypothesized that using a flexible bronchoscope would lead to securing the airway faster than the Eschmann introducer when either device is used in addition to video-laryngoscopy. METHODS: Twenty-eight anesthesia trainees (n=14/group) were randomized to use either one of the rescue devices and video-recorded in a simulated scenario of emergency cesarean delivery. The primary outcome was the time difference in establishing intubation; secondary outcomes were the differences in incidence of hypoxemia, need for bag and mask ventilation, and failed intubation between the two rescue devices. RESULTS: Mean (±SD) time to intubation using flexible bronchoscopy was shorter compared to using an Eschmann introducer (24 ±â€¯10 vs 86 ±â€¯35 s; P<0.0001; difference in mean 62 seconds, 95% CI 42 to 82 seconds). In the fiberoptic bronchoscopy group, there were no episodes of hypoxemia or need for bag and mask ventilation; in contrast both such events occurred frequently in the Eschmann introducer group (71%, 10/14); P=0.0002). All flexible bronchoscopy-aided intubations were established on the first attempt. The incidence of failed intubation was similar in both groups. CONCLUSIONS: Our data from simulated emergency tracheal intubation suggest that flexible bronchoscopy combined with video-laryngoscopy results in faster intubation time than using an Eschmann introducer combined with video-laryngoscopy.

2.
Qual Life Res ; 20(7): 1011-22, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21359974

RESUMEN

PURPOSE: To develop and psychometrically evaluate two questionnaires measuring both positive and negative postnatal health of mothers (M-PHI) and fathers (F-PHI) during the first year of parenting. METHODS: The M-PHI and the F-PHI were developed in four stages. Stage 1: Postnatal women's focus group (M-PHI) and postnatal fathers' postal questionnaire (F-PHI); Stage 2: Qualitative interviews; Stage 3: Pilot postal survey and main postal survey; and Stage 4: Test-retest postal survey. RESULTS: The M-PHI consisted of a 29-item core questionnaire with six main scales and five conditional scales. The F-PHI consisted of a 27-item questionnaire with six main scales. All scales achieved good internal reliability (Cronbach's α 0.66-0.87 for M-PHI, 0.72-0.90 for F-PHI). Intraclass correlation coefficients demonstrated high test-retest reliability (0.60-0.88). Correlation coefficients supported the criterion validity of the M-PHI and the F-PHI when tested against the Short-Form-12 (SF-12), Edinburgh Postnatal Depression Scale (EPDS) and the Warwick and Edinburgh Mental Well-Being Scale (WEMWBS). CONCLUSION: The M-PHI and F-PHI are valid, reliable, parent-generated instruments. These unique instruments will be invaluable for practitioners wishing to promote family-centred care and for trialists and other researchers requiring a validated instrument to measure both positive and negative health during the first postnatal year, as to date no such measurement has existed.


Asunto(s)
Padre/psicología , Estado de Salud , Encuestas Epidemiológicas/instrumentación , Madres/psicología , Responsabilidad Parental , Atención Posnatal , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios/normas , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA