Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Hosp Infect ; 104(4): 522-528, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32035121

RESUMEN

BACKGROUND: Ventilator-associated pneumonia surveillance is used as a quality indicator due to concerns that some cases may be preventable and may contribute to mortality. Various surveillance criteria exist for the purposes of national reporting, but a large-scale direct comparison has not been conducted. METHODS: A prospective cohort study applied two routinely used surveillance criteria for ventilator-associated pneumonia from the European Centre for Disease Control and the American Centers for Disease Control to all patients admitted to two large general intensive care units. Diagnostic rates and concordance amongst diagnostic events were compared. FINDINGS: A total of 713 at-risk patients were identified during the study period. The European surveillance algorithm returned a rate of 4.6 cases of ventilator-associated pneumonia per 1000 ventilation days (95% confidence interval 3.1-6.6) and the American surveillance system a rate of 5.4 (3.8-7.5). The concordance between diagnostic events was poor (Cohen's Kappa 0.127 (-0.003 to 0.256)). CONCLUSIONS: The algorithms yield similar rates, but the lack of event concordance reveals the absence of inter-algorithm agreement for diagnosing ventilator-associated pneumonia, potentially undermining surveillance as an indicator of care quality.


Asunto(s)
Neumonía Asociada al Ventilador/epidemiología , Vigilancia en Salud Pública/métodos , Vigilancia de Guardia , Adulto , Anciano , Algoritmos , Femenino , Hospitales , Humanos , Masculino , Persona de Mediana Edad , Neumonía Asociada al Ventilador/microbiología , Estudios Prospectivos , Escocia/epidemiología
2.
Biomed Opt Express ; 8(9): 4077-4095, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28966848

RESUMEN

We demonstrate determination of the location of the distal-end of a fibre-optic device deep in tissue through the imaging of ballistic and snake photons using a time resolved single-photon detector array. The fibre was imaged with centimetre resolution, within clinically relevant settings and models. This technique can overcome the limitations imposed by tissue scattering in optically determining the in vivo location of fibre-optic medical instruments.

3.
Biomed Opt Express ; 8(1): 243-259, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-28101415

RESUMEN

Previously unobtainable measurements of alveolar pH were obtained using an endoscope-deployable optrode. The pH sensing was achieved using functionalized gold nanoshell sensors and surface enhanced Raman spectroscopy (SERS). The optrode consisted of an asymmetric dual-core optical fiber designed for spatially separating the optical pump delivery and signal collection, in order to circumvent the unwanted Raman signal generated within the fiber. Using this approach, we demonstrate a ~100-fold increase in SERS signal-to-fiber background ratio, and demonstrate multiple site pH sensing with a measurement accuracy of ± 0.07 pH units in the respiratory acini of an ex vivo ovine lung model. We also demonstrate that alveolar pH changes in response to ventilation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA