Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Urol ; : 101097JU0000000000004186, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39146526

RESUMEN

PURPOSE: Ultrasonic propulsion is an investigational procedure for awake patients. Our purpose was to evaluate whether ultrasonic propulsion to facilitate residual kidney stone fragment clearance reduced relapse. MATERIALS AND METHODS: This multicenter, prospective, open-label, randomized, controlled trial used single block randomization (1:1) without masking. Adults with residual fragments (individually ≤5 mm) were enrolled. Primary outcome was relapse as measured by stone growth, a stone-related urgent medical visit, or surgery by 5 years or study end. Secondary outcomes were fragment passage within 3 weeks and adverse events within 90 days. Cumulative incidence of relapse was estimated using the Kaplan-Meier method. Log-rank test was used to compare the treatment (ultrasonic propulsion) and control (observation) groups. RESULTS: The trial was conducted from May 9, 2015, through April 6, 2024. Median follow-up (interquartile range) was 3.0 (1.8-3.2) years. The treatment group (n = 40) had longer time to relapse than the control group (n = 42; P < .003). The restricted mean time-to-relapse was 52% longer in the treatment group than in the control group (1530 ± 92 days vs 1009 ± 118 days), and the risk of relapse was lower (hazard ratio 0.30, 95% CI 0.13-0.68) with 8 of 40 and 21 of 42 participants, respectively, experiencing relapse. Omitting 3 participants not asked about passage, 24 treatment (63%) and 2 control (5%) participants passed fragments within 3 weeks of treatment. adverse events were mild, transient, and self-resolving, and were reported in 25 treated participants (63%) and 17 controls (40%). CONCLUSIONS: Ultrasonic propulsion reduced relapse and added minimal risk. CLINICAL TRIAL REGISTRATION NO.: NCT02028559.

2.
J Ultrasound Med ; 43(3): 513-523, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38050780

RESUMEN

OBJECTIVES: The number and distribution of lung ultrasound (LUS) imaging artifacts termed B-lines correlate with the presence of acute lung disease such as infection, acute respiratory distress syndrome (ARDS), and pulmonary edema. Detection and interpretation of B-lines require dedicated training and is machine and operator-dependent. The goal of this study was to identify radio frequency (RF) signal features associated with B-lines in a cohort of patients with cardiogenic pulmonary edema. A quantitative signal indicator could then be used in a single-element, non-imaging, wearable, automated lung ultrasound sensor (LUSS) for continuous hands-free monitoring of lung fluid. METHODS: In this prospective study a 10-zone LUS exam was performed in 16 participants, including 12 patients admitted with acute cardiogenic pulmonary edema (mean age 60 ± 12 years) and 4 healthy controls (mean age 44 ± 21). Overall,160 individual LUS video clips were recorded. The LUS exams were performed with a phased array probe driven by an open-platform ultrasound system with simultaneous RF signal collection. RF data were analyzed offline for candidate B-line indicators based on signal amplitude, temporal variability, and frequency spectrum; blinded independent review of LUS images for the presence or absence of B-lines served as ground truth. Predictive performance of the signal indicators was determined with receiving operator characteristic (ROC) analysis with k-fold cross-validation. RESULTS: Two RF signal features-temporal variability of signal amplitude at large depths and at the pleural line-were strongly associated with B-line presence. The sensitivity and specificity of a combinatorial indicator were 93.2 and 58.5%, respectively, with cross-validated area under the ROC curve (AUC) of 0.91 (95% CI = 0.80-0.94). CONCLUSION: A combinatorial signal indicator for use with single-element non-imaging LUSS was developed to facilitate continuous monitoring of lung fluid in patients with respiratory illness.


Asunto(s)
Edema Pulmonar , Síndrome de Dificultad Respiratoria , Humanos , Persona de Mediana Edad , Anciano , Adulto Joven , Adulto , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Sensibilidad y Especificidad , Ultrasonografía/métodos
3.
Artículo en Inglés | MEDLINE | ID: mdl-37074881

RESUMEN

Pulsed high-intensity focused ultrasound (pHIFU) uses nonlinearly distorted millisecond-long ultrasound pulses of moderate intensity to induce inertial cavitation in tissue without administration of contrast agents. The resulting mechanical disruption permeabilizes the tissue and enhances the diffusion of systemically administered drugs. This is especially beneficial for tissues with poor perfusion such as pancreatic tumors. Here, we characterize the performance of a dual-mode ultrasound array designed for image-guided pHIFU therapies in producing inertial cavitation and ultrasound imaging. The 64-element linear array (1.071 MHz, an aperture of 14.8×51.2 mm, and a pitch of 0.8 mm) with an elevational focal length of 50 mm was driven by the Verasonics V-1 ultrasound system with extended burst option. The attainable focal pressures and electronic steering range in linear and nonlinear operating regimes (relevant to pHIFU treatments) were characterized through hydrophone measurements, acoustic holography, and numerical simulations. The steering range at ±10% from the nominal focal pressure was found to be ±6 mm axially and ±11 mm azimuthally. Focal waveforms with shock fronts of up to 45 MPa and peak negative pressures up to 9 MPa were achieved at focusing distances of 38-75 mm from the array. Cavitation behaviors induced by isolated 1-ms pHIFU pulses in optically transparent agarose gel phantoms were observed by high-speed photography across a range of excitation amplitudes and focal distances. For all focusing configurations, the appearance of sparse, stationary cavitation bubbles occurred at the same P- threshold of 2 MPa. As the output level increased, a qualitative change in cavitation behavior occurred, to pairs and sets of proliferating bubbles. The pressure P- at which this transition was observed corresponded to substantial nonlinear distortion and shock formation in the focal region and was thus dependent on the focal distance of the beam ranging within 3-4 MPa for azimuthal F -numbers of 0.74-1.5. The array was capable of B-mode imaging at 1.5 MHz of centimeter-sized targets in phantoms and in vivo pig tissues at depths of 3-7 cm, relevant to pHIFU applications in abdominal targets.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Neoplasias Pancreáticas , Animales , Porcinos , Medios de Contraste , Ultrasonografía , Fantasmas de Imagen , Microburbujas , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos
4.
J Urol ; 208(5): 1075-1082, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36205340

RESUMEN

PURPOSE: Our goal was to test transcutaneous focused ultrasound in the form of ultrasonic propulsion and burst wave lithotripsy to reposition ureteral stones and facilitate passage in awake subjects. MATERIALS AND METHODS: Adult subjects with a diagnosed proximal or distal ureteral stone were prospectively recruited. Ultrasonic propulsion alone or with burst wave lithotripsy was administered by a handheld transducer to awake, unanesthetized subjects. Efficacy outcomes included stone motion, stone passage, and pain relief. Safety outcome was the reporting of associated anticipated or adverse events. RESULTS: Twenty-nine subjects received either ultrasonic propulsion alone (n = 16) or with burst wave lithotripsy bursts (n = 13), and stone motion was observed in 19 (66%). The stone passed in 18 (86%) of the 21 distal ureteral stone cases with at least 2 weeks follow-up in an average of 3.9±4.9 days post-procedure. Fragmentation was observed in 7 of the burst wave lithotripsy cases. All subjects tolerated the procedure with average pain scores (0-10) dropping from 2.1±2.3 to 1.6±2.0 (P = .03). Anticipated events were limited to hematuria on initial urination post-procedure and mild pain. In total, 7 subjects had associated discomfort with only 2.2% (18 of 820) propulsion bursts. CONCLUSIONS: This study supports the efficacy and safety of using ultrasonic propulsion and burst wave lithotripsy in awake subjects to reposition and break ureteral stones to relieve pain and facilitate passage.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Adulto , Humanos , Cálculos Renales/terapia , Litotricia/efectos adversos , Dolor/etiología , Ultrasonido , Cálculos Ureterales/terapia
5.
J Urol ; 207(5): 1067-1076, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35311351

RESUMEN

PURPOSE: We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses. MATERIALS AND METHODS: This was a prospective multi-institutional feasibility study recruiting subjects undergoing clinical ureteroscopy (URS) for at least 1 stone ≤12 mm as measured on computerized tomography. During the planned URS, either before or after ureteroscope insertion, BWL was administered with a handheld transducer, and any stone fragmentation and tissue injury were observed. Up to 3 stones per subject were targeted, each for a maximum of 10 minutes. The primary effectiveness outcome was the volume percent comminution of the stone into fragments ≤2 mm. The primary safety outcome was the independent, blinded visual scoring of tissue injury from the URS video. RESULTS: Overall, median stone comminution was 90% (IQR 20, 100) of stone volume with 21 of 23 (91%) stones fragmented. Complete fragmentation (all fragments ≤2 mm) within 10 minutes of BWL occurred in 9 of 23 stones (39%). Of the 6 least comminuted stones, likely causative factors for decreased effectiveness included stones that were larger than the BWL beamwidth, smaller than the BWL wavelength or the introduction of air bubbles from the ureteroscope. Mild reddening of the papilla and hematuria emanating from the papilla were observed ureteroscopically. CONCLUSIONS: The first study of BWL in human subjects resulted in a median of 90% comminution of the total stone volume into fragments ≤2 mm within 10 minutes of BWL exposure with only mild tissue injury.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Cálculos Renales/terapia , Litotricia/efectos adversos , Litotricia/métodos , Estudios Prospectivos , Resultado del Tratamiento , Cálculos Ureterales/terapia , Ureteroscopía/métodos
6.
J Appl Clin Med Phys ; 22(9): 345-359, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34346559

RESUMEN

BACKGROUND: High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required. METHODS: The acoustic pressure and power output was characterized by a fiber optic probe and a radiation force balance, respectively, with the electrical power up to 2000 W. An in situ acoustic energy was established as the clinical protocol at the electrical power up to 500 W. Temperature elevation inside the tissue sample was measured by a thermocouple array. Generated lesion volume at different in situ acoustic energies and pathological examination of the lesions was evaluated ex vivo. RESULTS: Acoustic pressure mapping showed the insignificant presence of side/grating lobes and pre- or post-focal peaks (≤-12 dB). Although distorted acoustic pressure waveform was found in the free field, the nonlinearity was reduced significantly after the beam propagating through tissue samples (i.e., the second harmonic of -11.8 dB at 500 W). Temperature elevation was <10°C at a distance of 10 mm away from a 20-mm target, which suggests the well-controlled HIFU energy deposition and no damage to the surrounding tissue. An acoustic energy in the range of 750-1250 J resulted in discrete lesions with an interval space of 5 mm between the treatment spots. Histology confirmed that the lesions represented a region of permanently damaged cells by heat fixation, without causing cell lysis by either cavitation or boiling. CONCLUSIONS: Our characterization and ex vivo evaluation protocol met the IDE requirement. The in-situ acoustic energy model will be used in clinical trials to deliver almost consistent energy to the various targets.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Acústica , Calibración , Fenómenos Mecánicos , Estados Unidos
7.
Ultrasound Med Biol ; 47(8): 2286-2295, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34078545

RESUMEN

Burst wave lithotripsy (BWL) is a technology under clinical investigation for non-invasive fragmentation of urinary stones. Under certain ranges of ultrasound exposure parameters, this technology can cause cavitation in tissue leading to renal injury. This study sought to measure the focal pressure amplitude needed to cause cavitation in vivo and determine its consistency in native tissue, in an implanted stone model and under different exposure parameters. The kidneys of eight pigs were exposed to transcutaneous BWL ultrasound pulses. In each kidney, two locations were targeted: the renal sinus and the kidney parenchyma. Each was exposed for 5 min at a set pressure level and parameters, and cavitation was detected using an active cavitation imaging method based on power Doppler ultrasound. The threshold was determined by incrementing the pressure amplitude up or down after each 5-min interval until cavitation occurred/subsided. The pressure thresholds were remeasured postsurgery, targeting an implanted stone or collecting space (in sham). The presence of a stone or sham surgery did not significantly impact the threshold for tissue cavitation. Targeting parenchyma instead of kidney collecting space and lowering the ultrasound pulse repetition frequency both resulted in an increased pressure threshold for cavitation.


Asunto(s)
Cálculos Renales/terapia , Litotricia/métodos , Animales , Femenino , Riñón/lesiones , Cálculos Renales/diagnóstico por imagen , Litotricia/efectos adversos , Presión , Porcinos , Ultrasonografía
8.
J Endourol ; 35(4): 506-511, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32940089

RESUMEN

Purpose: To test the effectiveness (Participant A) and tolerability (Participant B) of urinary stone comminution in the first-in-human trial of a new technology, burst-wave lithotripsy (BWL). Materials and Methods: An investigational BWL and ultrasonic propulsion system was used to target a 7-mm kidney stone in the operating room before ureteroscopy (Participant A). The same system was used to target a 7.5 mm ureterovesical junction stone in clinic without anesthesia (Participant B). Results: For Participant A, a ureteroscope inserted after 9 minutes of BWL observed fragmentation of the stone to <2 mm fragments. Participant B tolerated the procedure without pain from BWL, required no anesthesia, and passed the stone on day 15. Conclusions: The first-in-human tests of BWL pulses were successful in that a renal stone was comminuted in <10 minutes, and BWL was also tolerated by an awake subject for a distal ureteral stone. Clinical Trial NCT03873259 and NCT02028559.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Cálculos Urinarios , Humanos , Cálculos Renales/cirugía , Cálculos Ureterales/cirugía , Ureteroscopía , Cálculos Urinarios/terapia
9.
Artículo en Inglés | MEDLINE | ID: mdl-33156788

RESUMEN

Boiling histotripsy (BH) uses millisecond-long ultrasound (US) pulses with high-amplitude shocks to mechanically fractionate tissue with potential for real-time lesion monitoring by US imaging. For BH treatments of abdominal organs, a high-power multielement phased array system capable of electronic focus steering and aberration correction for body wall inhomogeneities is needed. In this work, a preclinical BH system was built comprising a custom 256-element 1.5-MHz phased array (Imasonic, Besançon, France) with a central opening for mounting an imaging probe. The array was electronically matched to a Verasonics research US system with a 1.2-kW external power source. Driving electronics and software of the system were modified to provide a pulse average acoustic power of 2.2 kW sustained for 10 ms with a 1-2-Hz repetition rate for delivering BH exposures. System performance was characterized by hydrophone measurements in water combined with nonlinear wave simulations based on the Westervelt equation. Fully developed shocks of 100-MPa amplitude are formed at the focus at 275-W acoustic power. Electronic steering capabilities of the array were evaluated for shock-producing conditions to determine power compensation strategies that equalize BH exposures at multiple focal locations across the planned treatment volume. The system was used to produce continuous volumetric BH lesions in ex vivo bovine liver with 1-mm focus spacing, 10-ms pulselength, five pulses/focus, and 1% duty cycle.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Abdomen , Animales , Bovinos , Hígado/diagnóstico por imagen , Ultrasonografía
10.
Proc Natl Acad Sci U S A ; 117(29): 16848-16855, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32631991

RESUMEN

In certain medical applications, transmitting an ultrasound beam through the skin to manipulate a solid object within the human body would be beneficial. Such applications include, for example, controlling an ingestible camera or expelling a kidney stone. In this paper, ultrasound beams of specific shapes were designed by numerical modeling and produced using a phased array. These beams were shown to levitate and electronically steer solid objects (3-mm-diameter glass spheres), along preprogrammed paths, in a water bath, and in the urinary bladders of live pigs. Deviation from the intended path was on average <10%. No injury was found on the bladder wall or intervening tissue.


Asunto(s)
Cálculos Renales/terapia , Terapia por Ultrasonido/métodos , Ondas Ultrasónicas , Animales , Porcinos , Transductores , Terapia por Ultrasonido/instrumentación
11.
Ultrasound Med Biol ; 46(7): 1802-1807, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32245546

RESUMEN

The color Doppler ultrasound twinkling artifact has been found to improve detection of kidney stones with ultrasound; however, it appears on only ∼60% of stones. Evidence from ex vivo kidney stones suggests twinkling arises from microbubbles stabilized in crevices on the stone surface. Yet it is unknown whether these bubbles are present on stones in humans. Here, we used a research ultrasound system to quantify twinkling in humans with kidney stones in a hyperbaric chamber. Eight human patients with non-obstructive kidney stones previously observed to twinkle were exposed to a maximum pressure of 4 atmospheres absolute (ATA) while breathing air, except during the 10-min pause at 1.6 ATA and while the pressure decreased to 1 ATA, during which patients breathed oxygen to minimize the risk of decompression sickness. A paired one-way t-test was used to compare the mean twinkle power at each pressure pause with baseline twinkling, with p < 0.05 considered to indicate significance. Results revealed that exposure to 3 and 4 ATA of pressure significantly reduced twinkle power by averages of 35% and 39%, respectively, in 7 patients (p = 0.04); data from the eighth patient were excluded because of corruption. This study supports the theory that microbubbles are present on kidney stones in humans.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Microburbujas , Humanos , Cálculos Renales/patología , Ultrasonografía/métodos
12.
J Endourol ; 34(11): 1167-1173, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32103689

RESUMEN

Objective: Our goals were to validate stone comminution with an investigational burst wave lithotripsy (BWL) system in patient-relevant conditions and to evaluate the use of ultrasonic propulsion to move a stone or fragments to aid in observing the treatment endpoint. Materials and Methods: The Propulse-1 system, used in clinical trials of ultrasonic propulsion and upgraded for BWL trials, was used to fragment 46 human stones (5-7 mm) in either a 15-mm or 4-mm diameter calix phantom in water at either 50% or 75% dissolved oxygen level. Stones were paired by size and composition, and exposed to 20-cycle, 390-kHz bursts at 6-MPa peak negative pressure (PNP) and 13-Hz pulse repetition frequency (PRF) or 7-MPa PNP and 6.5-Hz PRF. Stones were exposed in 5-minute increments and sieved, with fragments >2 mm weighed and returned for additional treatment. Effectiveness for pairs of conditions was compared statistically within a framework of survival data analysis for interval censored data. Three reviewers blinded to the experimental conditions scored ultrasound imaging videos for degree of fragmentation based on stone response to ultrasonic propulsion. Results: Overall, 89% (41/46) and 70% (32/46) of human stones were fully comminuted within 30 and 10 minutes, respectively. Fragments remained after 30 minutes in 4% (1/28) of calcium oxalate monohydrate stones and 40% (4/10) of brushite stones. There were no statistically significant differences in comminution time between the two output settings (p = 0.44), the two dissolved oxygen levels (p = 0.65), or the two calyx diameters (p = 0.58). Inter-rater correlation on endpoint detection was substantial (Fleiss' kappa = 0.638, p < 0.0001), with individual reviewer sensitivities of 95%, 86%, and 100%. Conclusions: Eighty-nine percent of human stones were comminuted with a clinical BWL system within 30 minutes under conditions intended to reflect conditions in vivo. The results demonstrate the advantage of using ultrasonic propulsion to disperse fragments when making a visual determination of breakage endpoint from the real-time ultrasound image.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Urinarios , Oxalato de Calcio , Humanos , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/terapia , Cálices Renales , Cálculos Urinarios/diagnóstico por imagen , Cálculos Urinarios/terapia
13.
J Endourol ; 33(10): 850-857, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31333058

RESUMEN

Purpose: Ultrasonic propulsion is an investigative modality to noninvasively image and reposition urinary stones. Our goals were to test safety and effectiveness of new acoustic exposure conditions from a new transducer, and to use simultaneous ureteroscopic and ultrasonic observation to quantify stone repositioning. Materials and Methods: During operation, ultrasonic propulsion was applied transcutaneously, whereas stone targets were visualized ureteroscopically. Exposures were 350 kHz frequency, ≤200 W/cm2 focal intensity, and ≤3-second bursts per push. Ureteroscope and ultrasound (US) videos were recorded. Video clips with and without stone motion were randomized and scored for motion ≥3 mm by independent reviewers blinded to the exposures. Subjects were followed with telephone calls, imaging, and chart review for adverse events. Results: The investigative treatment was used in 18 subjects and 19 kidneys. A total of 62 stone targets were treated ranging in size from a collection of "dust" to 15 mm. Subjects received an average of 17 ± 14 propulsion bursts (per kidney) for a total average exposure time of 40 ± 40 seconds. Independent reviewers scored at least one stone movement ≥3 mm in 18 of 19 kidneys (95%) from the ureteroscope videos and in 15 of 19 kidneys (79%) from the US videos. This difference was probably because of motion out of the US imaging plane. Treatment repositioned stones in two cases that would have otherwise required basket repositioning. No serious adverse events were observed with the device or procedure. Conclusions: Ultrasonic propulsion was shown to be safe, and it effectively repositioned stones in 95% of kidneys despite positioning and access restrictions caused by working in an operating room on anesthetized subjects.


Asunto(s)
Cálculos Renales/terapia , Litotricia/métodos , Terapia por Ultrasonido/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ureteroscopía/métodos
14.
J Endourol ; 33(10): 787-792, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31016998

RESUMEN

Introduction: Burst wave lithotripsy is an experimental technology to noninvasively fragment kidney stones with focused bursts of ultrasound (US). This study evaluated the safety and effectiveness of specific lithotripsy parameters in a porcine model of nephrolithiasis. Methods: A 6- to 7-mm human kidney stone was surgically implanted in each kidney of three pigs. A burst wave lithotripsy US transducer with an inline US imager was coupled to the flank and the lithotripter focus was aligned with the stone. Each stone was exposed to burst wave lithotripsy at 6.5 to 7 MPa focal pressure for 30 minutes under real-time image guidance. After treatment, the kidneys were removed for gross, histologic, and MRI assessment. Stone fragments were retrieved from the kidney to determine the mass comminuted to pieces <2 mm. Results: On average, 87% of the stone mass was reduced to fragments <2 mm. In three of five treatments, stones were completely comminuted to <2-mm fragments. In two of five treatments, stones were partially disintegrated, but larger fragments remained. One stone was not treated because no suitable acoustic window was identified. No injury was detected through gross, histologic, or MRI examination in the parenchymal tissue, although petechial damage and surface erosion were identified on the urothelium of the collecting system limited to the area around the stone. Conclusion: Burst wave lithotripsy can consistently produce stone fragments small enough to spontaneously pass by transcutaneous administration of US pulses. The data suggest that such exposures produce minimal injury to the kidney and urinary tract.


Asunto(s)
Cálculos Renales/terapia , Riñón/patología , Litotricia/métodos , Animales , Fenómenos Electromagnéticos , Humanos , Litotricia/efectos adversos , Porcinos , Transductores
15.
Artículo en Inglés | MEDLINE | ID: mdl-29994675

RESUMEN

Multielement focused ultrasound phased arrays have been used in therapeutic applications to treat large tissue volumes by electronic steering of the focus, to target multiple simultaneous foci, and to correct aberration caused by inhomogeneous tissue pathways. There is an increasing interest in using arrays to generate more complex beam shapes and corresponding acoustic radiation force patterns for manipulation of particles such as kidney stones. Toward this end, experimental and computational tools are needed to enable accurate delivery of desired transducer vibrations and corresponding ultrasound fields. The purpose of this paper was to characterize the vibrations of a 256-element array at 1.5 MHz, implement strategies to compensate for variability, and test the ability to generate specified vortex beams that are relevant to particle manipulation. The characterization of the array output was performed in water using both element-by-element measurements at the focus of the array and holography measurements for which all the elements were excited simultaneously. Both methods were used to quantify each element's output so that the power of each element could be equalized. Vortex beams generated using both compensation strategies were measured and compared to the Rayleigh integral simulations of fields generated by an idealized array based on the manufacturer's specifications. Although both approaches improved beam axisymmetry, compensation based on holography measurements had half the error relative to the simulation results in comparison to the element-by-element method.


Asunto(s)
Ultrasonografía/instrumentación , Diseño de Equipo , Holografía , Transductores , Vibración
16.
J Endourol ; 32(4): 344-349, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29433329

RESUMEN

PURPOSE: Burst wave lithotripsy (BWL) is a new technology in development to fragment urinary stones. Ultrasonic propulsion (UP) is a separate technology under investigation for displacing stones. We measure the effect of propulsion pulses on stone fragmentation from BWL. MATERIALS AND METHODS: Two artificial stone models (crystalline calcite, BegoStone plaster) and human calcium oxalate monohydrate (COM) stones measuring 5 to 8 mm were subjected to ultrasound exposures in a polyvinyl chloride tissue phantom within a water bath. Stones were exposed to BWL with and without propulsion pulses interleaved for set time intervals depending on stone type. Fragmentation was measured as a fraction of the initial stone mass fragmented to pieces smaller than 2 mm. RESULTS: BegoStone model comminution improved from 6% to 35% (p < 0.001) between BWL and BWL with interleaved propulsion in a 10-minute exposure. Propulsion alone did not fragment stones, whereas addition of propulsion after BWL slightly improved BegoStone model comminution from 6% to 11% (p < 0.001). BegoStone model fragmentation increased with rate of propulsion pulses. Calcite stone fragmentation improved from 24% to 39% in 5 minutes (p = 0.047) and COM stones improved from 17% to 36% (p = 0.01) with interleaved propulsion. CONCLUSIONS: BWL with UP improved stone fragmentation compared with BWL alone in vitro. The improvement was greatest when propulsion pulses are interleaved with BWL treatment and when propulsion pulses are applied at a higher rate. Thus, UP may be a useful adjunct to enhance fragmentation in lithotripsy in vivo.


Asunto(s)
Litotricia/métodos , Terapia por Ultrasonido/métodos , Cálculos Urinarios/terapia , Oxalato de Calcio , Terapia Combinada/métodos , Humanos , Fantasmas de Imagen , Cálculos Urinarios/química
17.
Urology ; 111: 225-229, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28964820

RESUMEN

OBJECTIVE: To evaluate in more detail the effectiveness of a new designed more efficient ultrasonic propulsion for large stones and specific stone compositions in a tissue phantom model. In the first clinical trial of noninvasive ultrasonic propulsion, urinary stones of unknown compositions and sizes up to 10 mm were successfully repositioned. MATERIALS AND METHODS: The study included 8- to 12-mm stones of 4 different primary compositions (calcium oxalate monohydrate, ammonium acid urate, calcium phosphate, and struvite) and a renal calyx phantom consisting of a 12 mm × 30 mm well in a 10-cm block of tissue-mimicking material. Primary outcome was the number of times a stone was expelled over 10 attempts, with ultrasonic propulsion burst duration varying from 0.5 seconds to 5 seconds. RESULTS: Overall success rate at expelling stones was 95%. All calcium oxalate monohydrate and ammonium acid urate stones were expelled 100% of the time. The largest stone (12 mm) became lodged within the 12-mm phantom calyx 25% of the time regardless of the burst duration. With the 0.5-second burst, there was insufficient energy to expel the heaviest stone (0.88 g), but there was sufficient energy at the longer burst durations. CONCLUSION: With a single burst, ultrasonic propulsion successfully moved most stones at least 3 cm and, regardless of size or composition, expelled them from the calyx. Ultrasonic propulsion is limited to the stones smaller than the calyceal space, and for each burst duration, related to maximum stone mass.


Asunto(s)
Cálculos Renales/terapia , Cálices Renales , Terapia por Ultrasonido , Humanos , Cálculos Renales/química , Cálculos Renales/patología , Fantasmas de Imagen
18.
Artículo en Inglés | MEDLINE | ID: mdl-28981413

RESUMEN

A noninvasive ultrasound (US) system to facilitate the passage of small kidney stones has been developed. The device incorporates a software-based US platform programmed with brightness mode and Doppler for visualizing stones, plus long duration focused pulses for repositioning stones using the same transducer. This paper characterizes the acoustic outputs of the ultrasonic propulsion device. Though the application and outputs are unique, measurements were performed based on the regulatory standards for both diagnostic US and extracorporeal lithotripters. The extended length of the pulse, time varying pressure output over the pulse, the use of focused targeting, and the need to regulate the output at shallow depths, however, required modifications to the traditional acoustic measurement methods. Output parameters included spatial-peak intensities, mechanical index (MI), thermal index, pulse energy, focal geometry, and target accuracy. The imaging and Doppler operating modes of the system meet the Food and Drug Administration acoustic power and intensity limits for diagnostic US device. Push mode operates at a maximum MI of 2.2, which is above the limit of 1.9 for diagnostic US, but well below any lithotripsy device and an ISPTA of 548 mW/cm2, which is below the 720-mW/cm2 limit for diagnostic US.


Asunto(s)
Cálculos Renales/terapia , Litotricia/métodos , Terapia por Ultrasonido/métodos , Humanos , Transductores , Terapia por Ultrasonido/instrumentación
19.
J Endourol ; 31(11): 1123-1130, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28847171

RESUMEN

PURPOSE: Greater visual contrast between calculi and tissue would improve ultrasound (US) imaging of urolithiasis and potentially expand clinical use. The color Doppler twinkling artifact has been suggested to provide enhanced contrast of stones compared with brightness mode (B-mode) imaging, but results are variable. This work provides the first quantitative measure of stone contrast in humans for B-mode and color Doppler mode, forming the basis to improve US for the detection of stones. MATERIALS AND METHODS: Using a research ultrasound system, B-mode imaging was tuned for detecting stones by applying a single transmit angle and reduced signal compression. Stone twinkling with color Doppler was tuned by using low-frequency transmit pulses, longer pulse durations, and a high-pulse repetition frequency. Data were captured from 32 subjects, with 297 B-mode and Doppler images analyzed from 21 subjects exhibiting twinkling signals. The signal to clutter ratio (i.e., stone to background tissue) (SCR) was used to compare the contrast of a stone on B-mode with color Doppler, and the contrast between stone twinkling and blood-flow signals within the kidney. RESULTS: The stone was the brightest object in only 54% of B-mode images and 100% of Doppler images containing stone twinkling. On average, stones were isoechoic with the tissue clutter on B-mode (SCR = 0 dB). Stone twinkling averaged 37 times greater contrast than B-mode (16 dB, p < 0.0001) and 3.5 times greater contrast than blood-flow signals (5.5 dB, p = 0.088). CONCLUSIONS: This study provides the first quantitative measure of US stone to tissue contrast in humans. Stone twinkling contrast is significantly greater than the contrast of a stone on B-mode. There was also a trend of stone twinkling signals having greater contrast than blood-flow signals in the kidney. Dedicated optimization of B-mode and color Doppler stone imaging could improve US detection of stones.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Ultrasonografía Doppler en Color , Artefactos , Femenino , Humanos , Cálculos Renales/patología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
20.
J Endourol ; 31(8): 793-799, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28537452

RESUMEN

PURPOSE: In the first-in-human trial of ultrasonic propulsion, subjects passed collections of residual stone fragments repositioned with a C5-2 probe. Here, effectiveness and safety in moving multiple fragments are compared between the C5-2 and a custom (SC-50) probe that produces a longer focal beam and burst duration. MATERIALS AND METHODS: Effectiveness was quantified by the number of stones expelled from a calyx phantom consisting of a 30-mm deep, water-filled well in a block of tissue mimicking material. Each probe was positioned below the phantom to move stones against gravity. Single propulsion bursts of 50 ms or 3 s duration were applied to three separate targets: 10 fragments of 2 different sizes (1-2 and 2-3 mm) and a single 4 × 7 mm human stone. Safety studies consisted of porcine kidneys exposed to an extreme dose of 10-minute burst duration, including a 7-day survival study and acute studies with surgically implanted stones. RESULTS: Although successful in the clinical trial, the shorter focal beam and maximum 50 ms burst duration of the C5-2 probe moved stones, but did not expel any stones from the phantom's 30-mm deep calyx. The results were similar with the SC-50 probe under the same 50 ms burst duration. Longer (3 s) bursts available with the SC-50 probe expelled all stones at both 4.5 and 9.5 cm "skin-to-stone" depths with lower probe heating compared to the C5-2. No abnormal behavior, urine chemistry, serum chemistry, or histological findings were observed within the kidney or surrounding tissues for the 10 min burst duration used in the animal studies. CONCLUSIONS: A longer focal beam and burst duration improved expulsion of a stone and multiple stone fragments from a phantom over a broad range of clinically relevant penetration depths and did not cause kidney injury in animal studies.


Asunto(s)
Cálculos Renales/terapia , Cálices Renales/patología , Posicionamiento del Paciente/métodos , Ultrasonido , Cálculos Urinarios/terapia , Animales , Diseño de Equipo , Femenino , Humanos , Riñón/patología , Litotricia/métodos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Fantasmas de Imagen , Piel/patología , Porcinos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA