RESUMEN
Over the last years, an increased number of studies have reported the use of cone beam weightbearing computed tomography (WBCT) in the assessment of foot and ankle pathology. This new technology has enabled to overcome the limits inherently related to two-dimensional radiographs (superimposition bias, operator-related bias, rotation bias) and to obtain images reproducing the bones and joints anatomy during physiological standing with a low radiation dose. We performed a review of the current literature to summarize the evidence about the use of 2D or 3D measurements on WBCT images in various foot and ankle conditions. Our aims were to describe measurements proposed so far and to report data on reliability and validity from primary authors.
Asunto(s)
Tobillo , Tomografía Computarizada de Haz Cónico , Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Imagenología Tridimensional , Reproducibilidad de los Resultados , Soporte de PesoRESUMEN
Two-stage exchange in infected total knee arthroplasty is a reliable technique, but it has a high rate of blood loss. The study aims to compare the pre-operative and post-operative haemoglobin levels, the rate of transfusion, and the blood loss in two-stage exchange. From July 2018 to July 2019, eighteen patients underwent two-stage exchange of their infected total knee arthroplasty. Local and systemic tranexamic acid was administered in both surgical stages. Calculated blood loss was 2246 mL (range 1528 - 2850) in the first stage and 2388 mL (1873 - 2829) during reimplantation, respectively. The corresponding transfusion rate was 55 % and 67%, respectively. With the numbers available, these differences were not significant. In conclusion, this study shows that the blood loss and transfusion rate are similar during the two stages of exchange knee arthroplasty for infection.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Transfusión Sanguínea , Antifibrinolíticos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica , Humanos , Ácido TranexámicoRESUMEN
Polyvinyl alcohol hydrogel implants (also known as Synthetic Cartilage Implant or Cartiva® have been described in the treatment of degeneration of the first and second metatarsophalangeal joint (MTPJ). We reviewed literature to report characteristics of devices on the market and investigate their efficacy and safety. Following the PRISMA checklist, the Medline and Scopus databases were searched, including studies reporting use of Cartiva® for treating joint degeneration of the first and second MPTJ. Studies were searched for surgical technique, postoperative protocol, clinical scores, complications and reoperations. We found that, although some studies suggest that the use of Synthetic Cartilage Implant (Cartiva® is effective in the treatment of hallux rigidus in providing symptoms relief without sacrifice of joint motion, the redundancy of cohorts reported in studies and the frequency of conflict of interest reported by authors weaken the strength of evidence available and warrant further studies. Regarding the treatment of the second MTPJ ailments, no recommendation can be formulated to date due to the lack of primary studies.
Asunto(s)
Hallux Rigidus , Articulación Metatarsofalángica , Cartílago , Hallux Rigidus/cirugía , Humanos , Articulación Metatarsofalángica/cirugía , Prótesis e ImplantesRESUMEN
Medial open-wedge (MOW) high tibial osteotomy (HTO) is proven treatment option, indicated in medial unicompartimental knee osteoarthritis (OA) and in varus OA. New devices and techniques were developed in last years, such as Activemotion plates with polyaxial locking system (Dualtec System®, NewClip-Technics) and PSI technique. We describe outcomes and rate of complications in patients treated with Activemotion plates and PSI technique. From January 2019 to August 2019 a sample of 77 cases (72 NCT plates, 5 PSI technique) was observed, evaluating the rate of complications and the return to activity. The rate of complications is 2.6% and the mean time to return to activity is 10 weeks. MOW HTO with Activemotion plate has showed good results with a low rate of complications. About PSI technique, the preliminary results are excellent, but we need to increase the sample.
Asunto(s)
Osteotomía , Tibia , Placas Óseas , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Radiografía , Tibia/cirugía , Resultado del TratamientoRESUMEN
Over the past decade, the incidence of revision arthroplasty due to infection has increased substantially, often resulting in multiple surgical interventions with variable success rates and poor clinical outcome. Intraoperative wound irrigation has been proposed to reduce bacterial bioburden and contamination, but currently there is no widely accepted recommendation for the use of topical antiseptics, whether as separate molecules or as a mixed solution. We reviewed studies regarding the use of intraoperative topical antiseptics, their security profile and efficacy in preventing and treating infections of orthopedic implants and introduced a possible combination that may prove valuable in the future.