Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 72(6): 449-455, 2019 Jun.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29754808

RESUMEN

INTRODUCTION AND OBJECTIVES: Many patients with nonvalvular atrial fibrillation are still left without protection due to a contraindication for anticoagulants. This study aimed to establish the occurrence of stroke and major bleeding events in patients with nonvalvular atrial fibrillation and left atrial appendage closure with long-term follow-up and to explore the factors associated with higher long-term mortality. METHODS: Analysis of a multicenter single cohort prospectively recruited from 2009 to 2015. Thromboembolic and bleeding events were compared with those expected from CHA2DS2-VASc and HAS-BLED scores. Multivariate analysis examined variables associated with mortality during follow-up. RESULTS: A total of 598 patients (1093 patient-years) with a contraindication for anticoagulants were recruited (median 75.4 years). The success rate of left atrial appendage closure device implantation was 95.8%. Thirty patients (5%) experienced periprocedural complications. The rate of events (per 100 patient-years) during follow-up (mean 22.9 months; median 16.1 months) was as follows: death 7.0%; ischemic stroke 1.6% (vs 8.5% expected according to CHA2DS2-VASc; P < .001); intracranial hemorrhage 0.8%; gastrointestinal bleeding 3.2%; severe bleeding 3.9% (vs 6.3% expected by HAS-BLED, P = .002). These results were improved in the subgroup of 176 patients with follow-up > 24 months (mean follow-up 46.6 months, 683 patient-years) for severe bleeding 2.6% (vs 6.3% expected by HAS-BLED, P < .033). The factors significantly associated with higher mortality were age (HR, 1.1), intracranial hemorrhage (HR, 6.8), and stroke during follow-up (HR, 2.7). CONCLUSIONS: Left atrial appendage closure significantly reduced the incidence of stroke and bleeding events and the benefit was maintained. Intracranial hemorrhage, age and stroke were associated with higher mortality.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Sistema de Registros , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Portugal/epidemiología , Estudios Prospectivos , España/epidemiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
2.
Int J Cardiol ; 169(5): 359-65, 2013 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-24128731

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The aim of this study was to describe early experience and long-term follow-up with the CoreValve self-expanding aortic prosthesis at 42 Ibero-American hospitals. METHODS: Multiple centre observational study including 1220 consecutive patients with symptomatic severe aortic stenosis who are not suitable candidates for surgery and underwent transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System between December 2007 and May 2012. RESULTS: The registry included 1220 consecutive patients with a mean age of 80.8 ± 6.3 years and a mean logistic euroSCORE of 17.8% ± 13%. The procedural success rate was 96.1%. Hospital mortality was 7.3% and combined end-point was 21.3%. Aortic regurgitation after TAVI was present in 24.5% (Sellers grade ≥ 2). The estimated 1-year and 2-year survival rates were 82.1% and 73.4% respectively. The following issues were significant independent risk factors for hospital mortality: acute kidney failure (odds ratio 3.55); stroke (odds ratio 5.72); major bleeding (odds ratio 2.64) and euroSCORE (odds ratio 1.02). Long-term predictors of mortality were diabetes mellitus (hazard ratio 1.59, 95% confidence interval 1.09-2.31), severe chronic obstructive pulmonary disease (hazard ratio 1.85, 95% confidence interval 1.85-2.88), and functional classes NYHA III-IV (hazard ratio 1.31, 95% confidence interval 1.01-1.70). CONCLUSIONS: Transcatheter aortic valve implantation constitutes a safe and viable therapeutic option for high operative risk patients with severe aortic stenosis. Long-term prognosis is conditioned by associate comorbidities.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/tendencias , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Sistema de Registros , Anciano , Anciano de 80 o más Años , Animales , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/mortalidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Portugal/epidemiología , España/epidemiología , Tasa de Supervivencia/tendencias , Porcinos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA