Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Electrocardiol ; 72: 95-97, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35398737

RESUMEN

A 51-year-old man with Brugada syndrome (BrS) electrocardiogram (ECG) type I pattern underwent implantable cardiac monitor (ICM) insertion. After pre-insertion potential mapping, we could observe the patient-specific repolarization abnormalities on the subcutaneous ECG provided by the ICM. A few weeks later, we received remotely a device recording with a higher ST-segment elevation and a longer duration of the interval between the onset of the coved elevation and its termination at the isoelectric line. Our observation supports the conceptual premise that ICM could add information on quantifying the amount of time with abnormal ECG patterns rather than only for the diagnosis of cardiac arrhythmias.


Asunto(s)
Síndrome de Brugada , Electrocardiografía , Arritmias Cardíacas , Síndrome de Brugada/diagnóstico , Humanos , Masculino , Persona de Mediana Edad
2.
J Electrocardiol ; 71: 10-15, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34990932

RESUMEN

BACKGROUND: There is an unmet need for simple tools for monitoring QT intervals. The feasibility of measuring the QT interval on the single­lead subcutaneous electrocardiogram (subECG) recorded and transmitted by implantable cardiac monitors (ICMs) has never been tested. METHODS: We performed a standard ECG in patients who had already been implanted with a long sensing vector ICM (BIOMONITOR, Biotronik SE&Co.) to calculate the corrected QT interval in lead II (QTc ECG). The QTc was then evaluated on the subECG provided by ICM both by using the programmer printout (QTc subECG) and the snapshot transmitted via home monitoring (QTc HM). Values were compared with Bland-Altman analyses. RESULTS: The study cohort consisted of 23 ICM recipients (age 58 ± 19 years, 35% female) implanted mainly for unexplained syncope (78%). The mean QTc ECG interval was 404 ± 31 ms. The T-wave was visible and QTc could be calculated in all patients using the ICM programmer printout and in 21 (91%) patients remotely. The QTc subECG and QTc HM were 405 ± 34 and 406 ± 32 ms. Compared to the QTc ECG, Bland-Altman analyses revealed a bias of -0.9 (95% confidence interval: -6.8/4.9) ms and 0.1 (-12.7/12.9) ms for QTc subECG and QTc HM, respectively. CONCLUSIONS: The QTc interval can be reliably estimated on in-person and remote subECG in most patients without bias compared to the ECG lead II assessment. This technology has the potential to facilitate remote QT interval monitoring.


Asunto(s)
Electrocardiografía , Síndrome de QT Prolongado , Adulto , Anciano , Arritmias Cardíacas , Femenino , Humanos , Síndrome de QT Prolongado/diagnóstico , Masculino , Persona de Mediana Edad , Síncope
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA