RESUMEN
BACKGROUND: Muscle injuries are common in professional sports, especially in football. Recent epidemiological studies showed that muscle injuries account for more than 30% of professional football injuries (1.8-2.2/1000â¯h exposure); however, even though there are significant differences within a European comparison, a single professional football team diagnosed on average 12 muscle injuries per season, corresponding to more than 300 availability days lost. OBJECTIVE: The aim of this work is to present the diagnosis, general treatment and comprehensive management of muscle injuries in professional football. MATERIAL AND METHODS: The present work is based on current scientific findings, experiences of the authors and examples from routine practice in the management of muscle injuries in a professional sports environment. RESULTS AND CONCLUSION: The authors present a model of gradual progression for the treatment of muscular injuries and their rehabilitation. Due to the time-pressured nature of the professional sports environment, often promoted by coaches and media, this model could help lead players to recover as quickly as possible and return to competitive sports without relapse or sequel injury. This model integrates the player into the treatment plan. The progression sequences in the rehabilitation should be made clear to players and other parties involved, which are crucial for optimal healing. Even if absolute certainty cannot be achieved, i.e. the occurrence of re-injury or secondary injury, this model attempts to minimize the level of risk involved for the returning athlete. Since it is hardly possible to act strictly in line with more conservative guidelines due to the particular circumstances of the professional sport environment, the experiences of the authors are presented in the sense of best practice in order to support future decision-making processes.
Asunto(s)
Traumatismos en Atletas , Fútbol , Medicina Deportiva , Humanos , Fútbol/lesionesRESUMEN
Laser interstitial thermotherapy (LITT) is a minimally invasive technique used to thermally destroy tumour cells. Being based on hyperthermia, LITT outcome depends on the temperature distribution inside the tissue. Recently, CT scan thermometry, based on the dependence of the CT number (HU) on tissue temperature (T) has been introduced during LITT; it is an attractive approach to monitor T because it overcomes the concerns related to the invasiveness. We performed LITT on nine ex vivo swine livers at three different laser powers, (P=1.5 W, P=3 W, P=5 W) with a constant treatment time t=200 s; HU is averaged on two ellipsoidal regions of interest (ROI) of 0.2 cm2, placed at two distances from the applicator (d=3.6 mm and d=8.7 mm); a reference ROI was placed away from the applicator (d=30 mm). The aim of this study is twofold: 1) to evaluate the effect of the T increase in terms of HU variation in ex vivo swine livers undergoing LITT; and 2) to estimate the P value for tissue vaporization. To the best of our knowledge, this is the first study focused on the HU variation in swine livers undergoing LITT at different P. The reported findings could be useful to assess the effect of LITT on the liver in terms of both T changes and tissue vaporization, with the aim to obtain an effective therapy.
Asunto(s)
Hipertermia Inducida/instrumentación , Neoplasias/terapia , Tomografía Computarizada por Rayos X/instrumentación , Animales , Diseño de Equipo , Hipertermia Inducida/métodos , Terapia por Láser/instrumentación , Rayos Láser , Hígado/patología , Neoplasias/patología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Porcinos , Temperatura , Termometría , Tomografía Computarizada por Rayos X/métodos , VolatilizaciónRESUMEN
Together with race, stature and age, sex is a main component of the biological identity. Thanks to its proportional correlation with parts of the human body, sex can be evaluated form the skeleton. The most accurate approach to determine sex by bone size is based on os coxae or skull. After natural disaster their presence can never be guaranteed, therefore the development of methods of sex determination using other skeletal elements can result crucial. Herein, sexual dimorphism in the human scapula is used to develop a two-variable discriminant function for sex estimation. We have enrolled 100 males and 100 females who underwent thoracic CT scan evaluation and we have estimated two scapular diameters. The estimation has been carried out by analyzing images of the scapulae of each patient after three dimensional post-processing reconstructions. The two-variable function allows to obtain an overall accuracy of 88% on the calibration sample. Furthermore, we have employed the mentioned function on a collection of 10 individual test sample from the collection of the "Museo di Anatomia Umana di Firenze" of the Università degli Studi di Firenze; sex has been correctly predicted on 9 skeletons.
Asunto(s)
Escápula/anatomía & histología , Determinación del Sexo por el Esqueleto/métodos , Tomografía Computarizada por Rayos X , Anciano , Calibración , Análisis Discriminante , Femenino , Antropología Forense , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Determinación del Sexo por el Esqueleto/normas , Población BlancaRESUMEN
Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes the invasiveness of other techniques used to monitor temperature during LITT. The averaged CT number (ROI = 0.02 cm(2)) of an ex vivo swine pancreas is monitored during LITT (Nd:YAG laser power of 3 W, treatment time: 120 s) at different distances from the applicator (from 4 to 30 mm). The averaged CT number shows a clear decrease during treatment: it is highest at 4 mm from the applicator (mean variation in the whole treatment of -0.256 HU s(-1)) and negligible at 30 mm, since the highest temperature increase is present close to the applicator (i.e., 45 °C at 4 mm and 25 °C at 6 mm). To obtain the relationship between CT numbers and pancreas temperature, the reference temperature was measured by 12 fiber Bragg grating sensors. The CT number decreases as a function of temperature, showing a nonlinear trend with a mean thermal sensitivity of -0.50 HU °C(-1). Results here reported are the first assessment of pancreatic CT number dependence on temperature, at the best of our knowledge. Findings can be useful to further investigate CT scan thermometry during LITT on the pancreas.
Asunto(s)
Técnicas de Ablación , Rayos Láser , Páncreas/diagnóstico por imagen , Páncreas/efectos de la radiación , Porcinos , Termometría/métodos , Tomografía Computarizada por Rayos X , Animales , Calibración , Estudios de Factibilidad , TemperaturaRESUMEN
PURPOSE: Percutaneous lung biopsies (PLBs) performed for the evaluation of pulmonary masses require image guidance to avoid critical structures. A new CT navigation system (SIRIO, "Sistema robotizzato assistito per il puntamento intraoperatorio") for PLBs was validated. METHODS: The local Institutional Review Board approved this retrospective study. Image-guided PLBs in 197 patients were performed with a CT navigation system (SIRIO). The procedures were reviewed based on the number of CT scans, patients' radiation exposure and procedural time recorded. Comparison was performed with a group of 72 patients undergoing standard CT-guided PLBs. Sensitivity, specificity and overall diagnostic accuracy were assessed in both groups. RESULTS: SIRIO-guided PLBs showed a significant reduction in procedure time, number of required CT scans and the radiation dose administered to patients ([Formula: see text]). In terms of diagnostic accuracy, SIRIO proved to be more accurate for small-sized lesions ([Formula: see text]20 mm) than standard CT-guidance. CONCLUSION: SIRIO proved to be a reliable and effective tool when performing CT-guided PLBs and was especially useful for sampling small ([Formula: see text]20 mm) lesions.
Asunto(s)
Fluoroscopía/métodos , Biopsia Guiada por Imagen/métodos , Enfermedades Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico , Radiografía Intervencional/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Interfaz Usuario-Computador , Anciano , Diseño de Equipo , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
PURPOSE: The authors sought to determine the diagnostic performance of dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging in the evaluation of prostate cancer before and after transrectal high-intensity focused ultrasound (HIFU) treatment. MATERIALS AND METHODS: We analysed 25 patients with prostate cancer. The prostate-specific antigen (PSA) value was evaluated 1, 4 and 6 months after treatment. DCE-MR imaging was performed the day prior to and 1, 4 and 6 months after HIFU treatment. Transrectal prostate biopsies were obtained at the time of diagnosis and 6 months after treatment. RESULTS: Before treatment, intraglandular lesions were considered to be potential sites of neoplasm and subsequently confirmed as sites of prostate adenocarcinoma in all 25 patients based on prostatespecific antigen (PSA) values and histological examinations (rho=1; p<0.001). Using histology as the gold standard, DCE-MR imaging displayed 100% sensitivity, 100% specificity, 100% positive predictive value and 100% negative predictive value before treatment. After HIFU treatment, DCE-MR imaging showed 100% sensitivity and 96% specificity. CONCLUSIONS: DCE-MR imaging can be used to visualise prostate adenocarcinoma. Several morphological and postgadolinium modifications in the follow-up DCE-MR images after HIFU treatment were also observed.
Asunto(s)
Adenocarcinoma/patología , Adenocarcinoma/cirugía , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Ultrasonido Enfocado Transrectal de Alta Intensidad , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Medios de Contraste , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Meglumina , Persona de Mediana Edad , Compuestos Organometálicos , Valor Predictivo de las Pruebas , Antígeno Prostático Específico/sangre , Sensibilidad y Especificidad , Resultado del TratamientoRESUMEN
PURPOSE: This study was undertaken to assess the reliability of the posterior approach under ultrasonographic guidance (PAUGA), with the arm abducted, before performing direct magnetic resonance (MR) arthrography of the shoulder. MATERIALS AND METHODS: A total of 111 (82 men, 29 women; mean age, 24 years) underwent direct MR arthrography of the shoulder. Patients were enrolled because of glenohumeral instability (n=71), chronic shoulder pain (n=25), suspicion of rotator cuff tear (n=13) and adhesive capsulitis (n=2). Patients were placed in the lateral position, on the contralateral side to that being examined; the arm of the shoulder undergoing the examination was placed in slight internal rotation with the hand under the contralateral armpit. A gadolinium-based solution was injected into the articular capsule under cryoanaesthesia and sonographic guidance. A posterior approach was systematically applied. For each patient, the number of injection attempts, room time, complications and pain, as recorded on a 10-point visual analogue scale (VAS), were noted. For quantitative parameters (room time and pain intensity), the mean and standard deviation (SD) were calculated. RESULTS: Direct MR arthrographies were performed successfully in all patients; no immediate or late major complications were observed. Fourteen patients (12.6%) reported temporary and self-limiting compromise of arm movements, and 13 patients (11.7%) reported a vagal reaction not requiring medication. In 102 cases (92%), the injection was successful at the first attempt, whereas in the remaining nine cases (8%), needle repositioning without any additional puncture was required to obtain clear sonographic depiction of the position of the needle tip. Mean room time was 7.2±1.4 min. Mean pain intensity was 3.2±0.4 on the 10-point VAS scale. CONCLUSIONS: PAUGA is a reliable and rapid technique that is well tolerated by patients and easy for the radiologist to perform.
Asunto(s)
Artropatías/diagnóstico , Imagen por Resonancia Magnética/métodos , Articulación del Hombro/patología , Ultrasonografía Intervencional , Medios de Contraste , Femenino , Gadolinio , Compuestos Heterocíclicos , Humanos , Artropatías/diagnóstico por imagen , Masculino , Compuestos Organometálicos , Dimensión del Dolor , Posicionamiento del Paciente , Punciones , Articulación del Hombro/diagnóstico por imagen , Adulto JovenRESUMEN
PURPOSE: This study was done to determine the diagnostic accuracy of magnetic resonance (MR) imaging in patients with rectal carcinoma by comparing post-chemoradiation MR imaging with pathological specimens. MATERIALS AND METHODS: We enrolled 39 patients with locally advanced rectal cancer. All patients received chemoradiation therapy before surgery and neoadjuvant chemoradiation therapy followed by MR imaging. MR images were analysed by a team of two expert radiologists unaware of the clinical and histopathological findings. RESULTS: Following neoadjuvant chemoradiation therapy, the analysis of MR images showed 23 (59%) patients with a rectal disease staged ≤T2 and 16 (41%) with a disease staged >T2. Post-treatment histological staging (TNM) revealed 13 patients with a disease >T2 and 26 patients with a disease ≤T2. Cohen's kappa to measure concordance between post-chemoradiation MR staging and histological response showed 83.6% concordance for disease confined to the serosa (≤T3): concordance was 97.22% for disease ≤N1 and 33.33% for disease >N1. CONCLUSIONS: MR imaging is critical for discovering T3 disease; moreover, morphological MR imaging does not always provide the opportunity to discern small residual cancer cells hidden in fibrotic tissue that could cause involvement of circumferential resection margin (CRM) on histology.
Asunto(s)
Quimioradioterapia , Imagen por Resonancia Magnética/métodos , Neoplasias del Recto/terapia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Capecitabina , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Femenino , Fluorouracilo/administración & dosificación , Fluorouracilo/análogos & derivados , Humanos , Interpretación de Imagen Asistida por Computador , Metástasis Linfática , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante , Estadificación de Neoplasias , Compuestos Organoplatinos/administración & dosificación , Oxaliplatino , Dosificación Radioterapéutica , Radioterapia Conformacional , Neoplasias del Recto/patología , Resultado del TratamientoRESUMEN
PURPOSE: This study was done to evaluate the feasibility and safety of radiofrequency ablation (RFA) of renal cell carcinomas (RCCs) in patients with solitary kidney. MATERIALS AND METHODS: Seven patients (two men, five women; age range 52-70 years; mean age 59.7 years) were treated under computed tomography (CT) and ultrasound (US) guidance. Three patients had single lesions, and the remaining four had multiple lesions. Seventeen lesions (4 cortical, 13 exophytic, maximum diameter range 12-40 mm, mean 21.0 mm) not located close to the renal pelvis were treated. CT or magnetic resonance (MR) imaging follow-up studies were obtained for all patients at the end of the procedure and at 1, 3, 6 and 12 months; serum creatinine was also monitored. RESULTS: Ten ablation sessions were performed. In two patients, a perinephric haematoma was detected, and one of these patients had two episodes of self-limiting haematuria. Contrast-enhanced CT and MR imaging at the end of the procedure and at 1 month demonstrated 100% technical success; these results were confirmed at 3, 6 and 12 month. Fisher's test comparing serum creatinine obtained 1 day before and 1 day after the procedure showed no case of acute renal failure (mean serum creatinine 24 h before the procedure 1.02 mg/dl; mean serum creatinine 24 h after the procedure 0.95 mg/dl; p=0.114; not significant). Serum creatinine at follow-up was always within the normal range. CONCLUSIONS: Radiofrequency ablation in the solitary kidney is a safe and effective procedure for treating RCC.
Asunto(s)
Carcinoma de Células Renales/cirugía , Ablación por Catéter , Neoplasias Renales/cirugía , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Italia , Pruebas de Función Renal , Neoplasias Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía IntervencionalRESUMEN
PURPOSE: This study was undertaken to clinically validate the accuracy of a semiautomated software tool for analysing the enhancement curve in focal malignant bone lesions. MATERIALS AND METHODS: Twenty-three patients affected by cancer with malignant focal bone lesions underwent dynamic gadolinium-enhanced magnetic resonance (MR) imaging using the following protocol: T1-weighted turbo spin-echo sequences (time to repeat [TR] 600 ms, time to echo [TE] 8.6 ms, field of view [FOV] 40x40 cm) before and after intravenous injection of gadolinium-containing contrast agent. Image postprocessing was performed using the software DyCoH. Each region of interest (5x5 pixels), drawn to include the area of the lesion with the highest values of the area under the curve map, was analysed to obtain time-intensity curves and relative perfusion parameters: time to peak (TTP), peak intensity (PI), slope (60-s slope), intensity at 60 s after contrast agent injection (60-s I) and final intensity (FI). RESULTS: Data were obtained by analysing 86 malignant lesions and 86 apparently normal bone regions. PI, 60-s slope, 60-s I and FI were significantly different between neoplastic and apparently normal (p<0.001) samples. Sensitivity, specificity and accuracy were, respectively, 94%, 93% and 94% at a PI threshold of 100 (signal-to-noise ratio), with positive and negative predictive values of 93% and 94%. At a threshold value of 0.85 for 60-s slope, sensitivity and specificity values were both 91%. CONCLUSIONS: The semiautomated technique we report appears to be accurate for identifying neoplastic tissue and for mapping perfusion parameters, with the added value of a consistent measurement of perfusion parameters on colour-coded maps.