RESUMEN
PURPOSE: High altitude results in lower barometric pressure and hence partial pressure of O2 decrease can lead to several molecular and cellular changes, such as generation of reactive oxygen species (ROS). Electron Paramagnetic Resonance technique was adopted in the field, to evaluate the effects of acute and sub-acute hypobaric hypoxia (HH) on ROS production by micro-invasive method. Biological biomarkers, indicators of oxidative stress, renal function and inflammation were investigated too. METHODS: Fourteen lowlander subjects (mean age 27.3 ± 5.9 years) were exposed to HH at 3269 m s.l. ROS production, related oxidative damage to cellular components, systemic inflammatory response and renal function were determined through blood and urine profile performed at 1st, 2nd, 4th, 7th, and 14th days during sojourn. RESULTS: Kinetics of changes during HH exposition showed out significant (range p < 0.05-0.0001) increases that at max corresponds to 38% for ROS production rate, 140% for protein carbonyl, 44% for lipid peroxidation, 42% for DNA damage, 200% for inflammatory cytokines and modifications in renal function (assessed by neopterin concentration: 48%). Conversely, antioxidant capacity significantly (p < 0.0001) decreased - 17% at max. CONCLUSION: This 14 days in-field study describes changes of oxidative-stress biomarkers during HH exposure in lowlanders. The results show an overproduction of ROS and consequent oxidative damage to protein, lipids and DNA with a decrease in antioxidant capacity and the involvement of inflammatory status and a transient renal dysfunction. Exposure at high altitude induces a hypoxic condition during acute and sub-acute phases accompanied by molecular adaptation mechanism indicating acclimatization.
Asunto(s)
Mal de Altura/metabolismo , Estrés Oxidativo , Adulto , Mal de Altura/sangre , Mal de Altura/orina , Citocinas/sangre , Daño del ADN , Femenino , Hemoglobinas/metabolismo , Humanos , Masculino , Neopterin/orina , Carbonilación ProteicaRESUMEN
Essentials Direct oral anticoagulants (DOACs) do not require laboratory monitoring currently. DOAC specific measurements were performed at trough in patients with atrial fibrillation. Patients who developed thromboembolic events showed lower DOAC plasma levels. This study supports the concept of measuring DOAC levels at steady state. SUMMARY: Background Direct oral anticoagulants (DOACs) are administered at fixed doses without the need for dose adjustment according to laboratory testing. High interindividual variability in drug blood levels has been shown with all DOACs. To evaluate a possible relationship between DOAC C-trough anticoagulant levels and thromboembolic events, 565 consecutive naive patients with atrial fibrillation (AF) were enrolled in this study performed within the START Laboratory Registry. Methods DOAC-specific measurements (diluted thrombin time or anti-activated factor II calibrated for dabigatran; anti-activated FX calibrated for rivaroxaban or apixaban) at C-trough were performed locally at steady state within 15-25 days after the start of treatment. For each DOAC, the interval of C-trough levels, from the limit of quantification to the highest value, was subdivided into four equal classes, and results were attributed to these classes; the median values of results were also calculated. Thromboembolic complications occurring during 1 year of follow-up were recorded. Results Thromboembolic events (1.8%) occurred in 10 patients who had baseline C-trough levels in the lowest class of drug levels. The incidence of thromboembolic events among patients with DOAC C-trough levels in the lowest level class was 2.4%, and that in the remaining groups was 0%. The patients with thrombotic complications also had a higher mean CHA2 DS2 -VASc score than that of the total patient population: 5.3 (95% confidence interval [CI] 4.3-6.3 versus 3.0 (95% CI 2.9-3.1). Conclusion In this study cohort, thrombotic complications occurred only in DOAC-treated AF patients who had very low C-trough levels, with a relatively high CHA2 DS2 -VASc score. Larger studies are warranted to confirm these preliminary observations.
Asunto(s)
Antitrombinas/administración & dosificación , Antitrombinas/sangre , Fibrilación Atrial/tratamiento farmacológico , Monitoreo de Drogas/métodos , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/sangre , Tromboembolia/prevención & control , Administración Oral , Adulto , Anciano , Anciano de 80 o más Años , Antitrombinas/efectos adversos , Fibrilación Atrial/sangre , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Pruebas de Coagulación Sanguínea , Dabigatrán/administración & dosificación , Dabigatrán/efectos adversos , Dabigatrán/sangre , Inhibidores del Factor Xa/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Datos Preliminares , Pirazoles/administración & dosificación , Pirazoles/efectos adversos , Pirazoles/sangre , Piridonas/administración & dosificación , Piridonas/efectos adversos , Piridonas/sangre , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Rivaroxabán/administración & dosificación , Rivaroxabán/efectos adversos , Rivaroxabán/sangre , Tromboembolia/sangre , Tromboembolia/diagnóstico , Tromboembolia/etiología , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION: Several specific assays are commercially available to determine dabigatran anticoagulant activity. Aims of this multicenter and multiplatform study were to compare five methods for dabigatran measurement and investigate their performances in the low concentration range. METHODS: Dabigatran levels were analyzed in 295 plasma samples from patients enrolled in the START-Laboratory Register by the following methods using dedicated calibrators and controls: STA-ECA II (Diagnostica Stago), standard and low range Hemoclot Thrombin Inhibitors (Hyphen BioMed), Direct Thrombin Inhibitor Assay (Instrumentation Laboratory), Direct Thrombin Inhibitor Assay (Siemens), Technoclot DTI (Technoclone). RESULTS: Methods showed variable agreement with the Hemoclot Thrombin Inhibitors assay used as reference test, with modest under- or overestimations (Bland-Altman bias from -17.3 to 4.0 ng/mL). Limits of detection and quantification varied depending on the assay (4-52 and 7-82 ng/mL, respectively). Between-run precision and accuracy were good for all methods for both quality control levels. Assay's repeatability assessed at very low dabigatran concentrations (from 10 to 60 ng/mL) was also acceptable, variability generally increased at lower drug levels. CONCLUSION: The five dabigatran-specific assays evaluated in this study provided reliable assessment of dabigatran plasma levels, although showing different performances.
Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Dabigatrán/sangre , Antitrombinas , Humanos , Límite de Detección , Control de Calidad , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Intense physical stress might promote inflammatory responses, whereas a regular physical exercise has positive influence. Little is known on the acute metabolic and inflammatory responses to different levels of strenuous exercise in trained athletes. AIM: To compare the short-term effect of two different ultra-endurance competitions on the inflammatory profile in male triathletes. METHODS: We studied 14 Ironman (IR) and 13 Half Ironman (HIR) before and after their own specific race. We assessed body composition and measured blood cells, lipids, iron metabolism and plasma levels of some acute-phase cytokines and inflammatory markers. RESULTS: After the race, IR showed reduced total body water and fat-free mass, not related with the duration of exercise, and increased white cells and platelets; high-density lipoprotein levels also increased. IR, but not HIR, showed reduced iron levels, increased ferritin and transferrin, reduced % saturated transferrin. HIR showed higher basal interleukin (IL)-6, tumour necrosis factor (TNF)-α, IL-10, IL-1ß than IR; however, the post-performance rise was greater in IR. Irisin increased only in HIR and osteocalcin decreased in IR. In the whole study group, delta of white blood cells was directly related with delta of monocyte chemoattractant protein 1, and Δ ferritin was inversely related with Δosteocalcin. CONCLUSIONS: A single ultra-endurance competition induces an inflammatory response depending on the duration of physical effort, with increased acute-phase cytokines, and an altered iron metabolism. Irisin, whose biological meaning is still uncertain, seems to be associated with acute variations of some metabolic parameters.
Asunto(s)
Biomarcadores/sangre , Citocinas/sangre , Inflamación/sangre , Esfuerzo Físico/fisiología , Atletas , Composición Corporal , Voluntarios Sanos , Humanos , Inflamación/fisiopatología , MasculinoRESUMEN
INTRODUCTION: Although most guidelines for quality assessment of INR PMs recommend specific procedures, no clear regulation or methodology is required for outpatients in our country. We have developed a specific INR portable monitor (PM) quality control system within our telemedicine organization to check over time quality performances and plan corrective actions. METHODS: Based on current guidelines for laboratory QC, the following aspects were assessed: suitability of PM, defined in terms of imprecision and accuracy; intra-assay imprecision, defined according to monthly revision of Levey-Jennings cards with data from each peripheral healthcare unit (PHU), using an internal QC provided by the manufacturer (CV ± 20% considered as acceptable); quarterly accuracy study, for assessing agreement between analytical instruments, based on duplicate analysis of three samples with INR values reflecting different therapeutic ranges (differences ± 0.5 considered as acceptable); external quality assessment (NEQAS). RESULTS: In the nine PHU, 18 portable monitors were used to perform 22 929 test during year 2010. Analytical imprecision was low, showing CVs always <5%. Accuracy check showed two of 216 results out of range (0.92%), thus providing timely indication for instrument replacement. The external QC NEQAS showed optimal performance. CONCLUSION: The current protocol for INR PMs quality assessment was effective to establish and maintain a reliable control of devices, ensuring the quality of analytical data over time. National authorities should be prompted to guarantee and apply correct protocols for INR-PM use.