Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Talanta ; 278: 126414, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38950500

RESUMEN

There is an ongoing effort in the US illicit drug market to make new psychoactive compounds more potent and addictive. Due to continuous chemical modifications, many fentanyl analogs are developed and mixed with more traditional illicit drugs, such as cocaine and heroin. Detecting fentanyl and fentanyl analogs in these illicit drug mixtures has become more crucial because of the increased potency and associated health risks. Most confirmatory procedures require time-consuming and expensive, highly sophisticated laboratory equipment and experimental procedures, which can delay critical information that might save a victim or find a suspect. In this study, we propose miniaturizing and accelerating this process by combining surface-enhanced Raman spectroscopy (SERS) analysis and paper spray mass spectrometry (PS-MS). For this aim, dual-purposed paper substrates were developed through soaking in Au/Ag nanostars suspensions. These novel, in-house prepared paper SERS substrates showed stability for up to four weeks with and without the presence of drug compounds. Fentanyl analogs with similar SERS spectra were differentiated by coupling with PS-MS. The limit of detection (LOD) for fentanyl on the paper substrates is 34 µg/mL and 0.32 µg/mL for SERS and PS-MS, respectively. Fentanyl and fentanyl analogs show selective SERS enhancement that helped to detect trace amounts of these opioids in heroin and cocaine street samples. In short, we propose the combination of SERS/PS-MS by using modified paper substrates to develop cost-effective, sensitive, rapid, portable, reliable, and reproducible methods to detect illicit drugs, especially trace amounts of fentanyl and fentanyl analogs in illicit drug mixtures. The combination of these two category A techniques allows for the identification of illicit drugs according to the SWGDRUG guidelines.


Asunto(s)
Fentanilo , Drogas Ilícitas , Espectrometría de Masas , Papel , Espectrometría Raman , Espectrometría Raman/métodos , Drogas Ilícitas/análisis , Fentanilo/análisis , Fentanilo/análogos & derivados , Espectrometría de Masas/métodos , Oro/química , Plata/química , Detección de Abuso de Sustancias/métodos , Límite de Detección , Nanopartículas del Metal/química , Humanos , Propiedades de Superficie
2.
Appl Spectrosc ; 78(7): 667-679, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38634156

RESUMEN

Fentanyl and fentanyl analogs are the main cause of recent overdose deaths in the United States. The presence of fentanyl analogs in illicit drugs makes it difficult to estimate their potencies. This makes the detection and differentiation of fentanyl analogs critically significant. Surface-enhanced Raman spectroscopy (SERS) can differentiate structurally similar fentanyl analogs by yielding spectroscopic fingerprints for the detected molecules. In previous years, five fentanyl analogs, carfentanil, furanyl fentanyl, acetyl fentanyl, 4-fluoroisobutyryl fentanyl (4-FIBF), and cyclopropyl fentanyl (CPrF), gained popularity and were found in 76.4% of the fentanyl analogs trafficked. In this study, we focused on 4-FIBF, CPrF, and structurally similar fentanyl analogs. We developed methods to differentiate these fentanyl analogs using theoretical and experimental methods. To do this, a set of fentanyl analogs were examined using density functional theory (DFT) calculations. The DFT results obtained in this project permitted the assignment of spectral bands. These results were then compared with normal Raman and SERS techniques. Structurally similar fentanyl analogs show important differences in their spectra, and they have been visually differentiated from each other both theoretically and experimentally. Additional results using principal component analysis and soft independent modeling of class analogy show they can be distinguished using this technique. The limit of detection values for FIBF and CPrF were determined to be 0.35 ng/mL and 4.4 ng/mL, respectively, using SERS. Experimental results obtained in this project can be readily implemented in field applications and smaller laboratories, where inexpensive portable Raman spectrometers are often present and used in drug analysis.


Asunto(s)
Teoría Funcional de la Densidad , Fentanilo , Espectrometría Raman , Espectrometría Raman/métodos , Fentanilo/análogos & derivados , Fentanilo/análisis , Fentanilo/química , Drogas Ilícitas/análisis , Drogas Ilícitas/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA