Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Acad Radiol ; 31(4): 1480-1490, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37914624

RESUMEN

RATIONALE AND OBJECTIVES: Recently, a new MRI-based classification for evaluating tibial spine fractures (TSFs) was developed to aid in treating these injuries. Our objective was to assess the detection efficacy, classification accuracy, and reliability of this classification in detecting and grading TSFs, as well as its impact on treatment strategy, compared to the Meyers and McKeever (MM) classification. MATERIALS AND METHODS: A retrospective study included 68 patients with arthroscopically confirmed TSFs. All patients had plain radiography and conventional MRI of the affected knee before arthroscopy. Three experienced radiologists independently reviewed all plain radiographs and MRI data and graded each patient according to MM and MRI-based classifications. The detection efficacy, classification accuracy, and inter-rater agreement of both classifications were evaluated and compared, using arthroscopic findings as the gold standard. RESULTS: The final analysis included 68 affected knees. Compared to the MM classification, the MRI-based classification produced 22.0% upgrade of TSFs and 11.8% downgrade of TSFs. According to the reviewers, the fracture classification accuracy of the MRI-based classification (91.2-95.6%) was significantly higher than that of the MM classification (73.5-76.5%, p = 0.002-0.01). The fracture detection rate of MRI-based classification (94.1-98.5%) was non-significantly higher than that of the MM classification (83.8-89.7%, p = 0.07-0.4). The soft tissue injury detection accuracy for MRI-based classification was 91.2-94.1%. The inter-rater reliability for grading TSFs was substantial for both the MM classification (κ = 0.69) and MRI-based classification (κ = 0.79). CONCLUSION: MRI-based classification demonstrates greater accuracy and reliability compared to MM classification for detecting and grading TSFs and associated soft tissue injuries.


Asunto(s)
Fracturas de Rodilla , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía
2.
Eur Radiol ; 33(2): 1286-1296, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35962816

RESUMEN

OBJECTIVE: To assess the diagnostic accuracy and agreement of CT and MRI in terms of the Bosniak classification version 2019 (BCv2019). MATERIALS AND METHODS: A prospective multi-institutional study enrolled 63 patients with 67 complicated cystic renal masses (CRMs) discovered during ultrasound examination. All patients underwent CT and MRI scans and histopathology. Three radiologists independently assessed CRMs using BCv2019 and assigned Bosniak class to each CRM using CT and MRI. The final analysis included 60 histopathologically confirmed CRMs (41 were malignant and 19 were benign). RESULTS: Discordance between CT and MRI findings was noticed in 50% (30/60) CRMs when data were analyzed in terms of the Bosniak classes. Of these, 16 (53.3%) were malignant. Based on consensus reviewing, there was no difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT (87.8%; 95% CI = 73.8-95.9% versus 75.6%; 95% CI = 59.7-87.6%; p = 0.09, 84.2%; 95% CI = 60.4-96.6% versus 78.9%; 95% CI = 54.4-93.9%; p = 0.5, and 86.7%; 95% CI = 64.0-86.6% versus 76.7%; 95% CI = 75.4-94.1%; p = 0.1, respectively). The number and thickness of septa and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. The inter-reader agreement (IRA) was substantial for determining the Bosniak class in CT and MRI (k = 0.66; 95% CI = 0.54-0.76, k = 0.62; 95% CI = 0.50-0.73, respectively). The inter-modality agreement of the BCv219 between CT and MRI was moderate (κ = 0.58). CONCLUSION: In terms of BCv2019, CT and MRI are comparable in the classification of CRMs with no significant difference in diagnostic accuracy and reliability. KEY POINTS: • There is no significant difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT. • The number of septa and their thickness and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. • The inter-reader agreement was substantial for determining the Bosniak class in CT and MRI and the inter-modality agreement of the BCv219 between CT and MRI was moderate.


Asunto(s)
Enfermedades Renales Quísticas , Neoplasias Renales , Humanos , Enfermedades Renales Quísticas/diagnóstico , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética , Riñón/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA