Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
3.
J Cardiothorac Vasc Anesth ; 38(7): 1467-1476, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38627172

RESUMEN

OBJECTIVE: To assess the intraoperative use of 3-dimensional transesophageal echocardiography (3D TEE) in cardiac surgical centers, the authors created a survey aimed at evaluating the availability of equipment and the use of 3D TEE for specific surgical and interventional procedures and single-image modalities. The respondents were asked to identify the perceived impact on patient management and current limitations to its routine use. DESIGN: A multiple choice 25-question online survey submitted to the members of the European Association of Cardiothoracic Anesthesia and Intensive Care (EACTAIC) on December 6, 2021, and closed on January 31, 2022. SETTING: An online survey. PARTICIPANTS: Registered EACTAIC members in 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 239 respondents from 44 different countries took part in the survey (27% of the total 903 EACTAIC members). Most respondents (59%) were TEE-certified by the National Board of Echocardiography, European Association of Cardiovascular Imaging (EACVI/EACTAIC), or had a national certificate. Of the respondents, 68% had no formal 3D TEE training. Eight percent of respondents had no 3D machines, whereas 40% had one for each operating room, and 33% had only one for the entire operating room block. 3D TEE was performed most frequently in more than 67% of cases for mitral valve surgery, and in more than 54% of cases for mitral and tricuspid clips, aortic valve, tricuspid valve, and aortic surgery. CONCLUSION: Current guidelines suggest integrating 3D TEE into all comprehensive examinations. The authors' survey reported that intraoperative 3D TEE was used in the majority of mitral valve surgery and only one-half of the other valve surgeries and transcatheter procedures. Its use may be explained by the availability of 3D machines, trained personnel, and limited time to perform TEE in the operating room. Educational initiatives for training in 3D TEE may further increase its routine use.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Encuestas y Cuestionarios , Europa (Continente) , Anestesia en Procedimientos Quirúrgicos Cardíacos/métodos , Cuidados Críticos/métodos , Sociedades Médicas , Monitoreo Intraoperatorio/métodos
4.
Ann Thorac Surg ; 117(4): 669-689, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38284956

RESUMEN

Enhanced Recovery After Surgery (ERAS) programs have been shown to lessen surgical insult, promote recovery, and improve postoperative clinical outcomes across a number of specialty operations. A core tenet of ERAS involves the provision of protocolized evidence-based perioperative interventions. Given both the growing enthusiasm for applying ERAS principles to cardiac surgery and the broad scope of relevant interventions, an international, multidisciplinary expert panel was assembled to derive a list of potential program elements, review the literature, and provide a statement regarding clinical practice for each topic area. This article summarizes those consensus statements and their accompanying evidence. These results provide the foundation for best practice for the management of the adult patient undergoing cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Recuperación Mejorada Después de la Cirugía , Cirujanos , Cirugía Torácica , Humanos , Atención Perioperativa/métodos , Procedimientos Quirúrgicos Cardíacos/métodos
5.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38099912

RESUMEN

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía Tridimensional
6.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37027228

RESUMEN

OBJECTIVE: During a transcatheter aortic valve implant (TAVI) procedure, intraprocedural complications that are manageable only by conversion to emergency open-heart surgery (E-OHS) occasionally occur. Contemporary data on the incidence and outcome of TAVI patients undergoing E-OHS are scarce. This study aimed to evaluate early and midterm outcomes following E-OHS of patients undergoing TAVI in a large tertiary care centre with immediate surgical backup availability for all TAVI procedures over a 15-year period. METHODS: Data from all patients undergoing transfemoral TAVI between 2006 and 2020 at the Heart Centre Leipzig were analysed. The study time was divided into 3 periods: 2006-2010 (P1), 2011-2015 (P2) and 2016-2020 (P3). Patients were grouped according to their surgical risk (high risk: EuroSCORE II ≥ 6%; low/intermediate risk: EuroSCORE II <6%). Primary outcomes were intraprocedural and in-hospital death and 1-year survival. RESULTS: During the study period, a total of 6903 patients underwent transfemoral TAVI. Among them, 74 (1.1%) required E-OHS [high risk, n = 66 (89.2%); low/intermediate risk, n = 8 (10.8%)]. The rate of patients requiring E-OHS was 3.5% (20/577 patients), 1.8% (35/1967 patients) and 0.4% (19/4359 patients) in study periods P1 to P3, respectively (P < 0.001). The proportion of patients who had E-OHS who were low/intermediate risk increased considerably over time (P1:0%; P28.6%; P3:26.3%; P = 0.077). Intraprocedural deaths occurred in 10 patients (13.5%), all of whom were high-risk. In-hospital mortality was 62.1% in high-risk patients and 12.5% in low/intermediate risk patients (P = 0.007). One-year survival was 37.8% in all patients undergoing E-OHS, 31.8% in high-risk patients and 87.5% in low/intermediate risk patients (log-rank P = 0.002). CONCLUSIONS: In-hospital and 1-year survival rates following E-OHS are higher in low/intermediate risk than in high-risk patients undergoing TAVI. An on-site cardiac surgical department with immediately available E-OHS capabilities is an important component of the TAVI team.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Centros de Atención Terciaria , Incidencia , Mortalidad Hospitalaria , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/métodos
7.
J Clin Anesth ; 77: 110577, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34799229

RESUMEN

OBJECTIVE: The primary objective of this study was to compare the association between cardiac surgical approach (thoracotomy vs. sternotomy) and incidence of persistent postoperative pain at 3 months. Secondary objectives were the incidence and intensity of persistent pain at 6 and 12 months, acute postoperative pain, analgesic requirement and its side effects. DESIGN: Single-center, prospective, observational study. Recruitment between December 2017 and August 2018. SETTING: Perioperative care at university-affiliated tertiary care centre. PATIENTS: 202 adults scheduled for cardiac surgery. Patients with chronic pain or behavioural disorder were excluded. INTERVENTIONS: Thoracotomy (n = 106) and sternotomy (n = 96). MEASUREMENTS: Pain scores and pain medication requirements from extubation until hospital discharge. Persistent postoperative pain was assessed using a telephone questionnaire. MAIN RESULTS: Incidence and intensity of pain was not significantly different between thoracotomy or sternotomy either in the short- or in the long-term follow-up. Incidence of persistent postoperative pain showed no differences between groups (30.2 vs 22.9% at 3 months (p = 0.297), 10.4 vs 7.3% at 6 months (p = 0.364) and 7.5 vs 7.3% at 12 months (p = 0.518) in thoracotomy and sternotomy group). A significant decrease of pain incidence was observed between 3 and 6 months (p < 0.001) but not between 6 and 12 months (p = 0.259) in both groups. ANOVA of repeated measures adjusted for confounding variable showed a decrease of acute pain intensity over time (p = 0.001) with no difference between groups (p = 0.145). Acute pain medication requirements were not different between the groups (p = 0.237 for piritramide and p = 0.743 for oxycodone) with no difference in their side effects. CONCLUSIONS: Our study showed no difference in short- or long-term pain in patients undergoing anterolateral thoracotomy or median sternotomy. Both groups showed a decrease in persistent postoperative pain incidence between 3 and 6 months without any significant changes at 12 months.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Esternotomía , Adulto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Estudios Prospectivos , Esternotomía/efectos adversos , Toracotomía/efectos adversos
8.
J Cardiothorac Vasc Anesth ; 36(7): 2022-2030, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34736862

RESUMEN

OBJECTIVE: The purpose of this study was to determine the incidence and types of interventions triggered during a drop of baseline near-infraredspectroscopy (NIRS) values in consecutive cardiac surgical patients. DESIGN: A single-center, retrospective observational study. SETTING: A university-affiliated tertiary care center. PARTICIPANTS: Three thousand three hundred two consecutive cardiac surgical patients from October 2016 to August 2017 Interventions: None. MEASUREMENTS AND MAIN RESULTS: Of the 1,972 patients who met the inclusion criteria, 576 (29.2%) patients showed NIRS deviation of -20% from baseline. Interventions performed during the drop of baseline NIRS values were documented in 285 (14.4%) patients, with a total of 391 interventions. Three hundred fifteen (80%) interventions were triggered by a deviation in NIRS and concomitant changes in standard monitoring parameters. Seventy-six (20%) interventions were triggered by NIRS deviation alone, with no concomitant pathologic deviation in standard monitoring. A total of 279 (71%) interventions were performed on patients who had no recommendation for NIRS monitoring by current national guidelines. Out of these, 30 (7.7%) interventions (1.3% of all patients) were performed based on NIRS monitoring alone. The higher risk deviation group had longer intensive care unit and hospital lengths of stays (one and 15 days) and postoperative delirium when compared with the no-deviation group (zero and 13 days) Conclusions: The authors' data suggested that most interventions triggered during the drop of baseline values during routine use of NIRS would have also been triggered by the concomitant changes in standard monitoring parameters. Routine use of NIRS for all cardiac surgical patients still is debatable and needs to be evaluated in a large prospective trial.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Espectroscopía Infrarroja Corta , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Unidades de Cuidados Intensivos , Oxígeno , Estudios Prospectivos , Estudios Retrospectivos , Espectroscopía Infrarroja Corta/métodos
9.
J Cardiovasc Surg (Torino) ; 63(2): 208-211, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34308614

RESUMEN

BACKGROUND: In this study we discuss the conditions of four patients with severe tricuspid valve (TV) regurgitation, in which a differentiated intraoperative transesophageal echocardiographic (TEE) analysis - as performed in TV-clipping procedures - provided major guidance for refined TV repair. METHODS: Between January 2019 and March 2020, four patients with central tricuspid regurgitation and an intercommisural jet underwent annuloplasty with an echo-guided plication stitch on the affected leaflet basis, especially anteroseptal. RESULTS: All patients underwent complex multiple valve (aortic- and/or mitral valve) surgery with concomitant TV-repair. No or mild TV regurgitation after TV repair was confirmed in the predischarge echocardiography in all patients. CONCLUSIONS: We conclude, that differentiated intraoperative TEE is essential for the surgical TV repair strategy. Plication of the anteroseptal commissure additionally performed to TV annuloplasty, is an easy and effective add-on in selected patients.


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anuloplastia de la Válvula Cardíaca/efectos adversos , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
11.
J Am Soc Echocardiogr ; 34(6): 676-689, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33675944

RESUMEN

Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) is a recently developed technique to reduce the risk of ostial coronary obstruction during transcatheter aortic valve replacement. Intraprocedural fluoroscopy and transesophageal echocardiography imaging are used complimentarily to guide the procedure. So far, no structured echocardiographic imaging protocol has been described for this intervention. Based on an experience of more than 50 BASILICA procedures at two different institutions, we present a step-by-step approach for transesophageal echocardiography guidance during BASILICA and highlight anatomical and procedural characteristics from an echocardiographic perspective.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Laceraciones , Pectinidae , Reemplazo de la Válvula Aórtica Transcatéter , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Vasos Coronarios , Ecocardiografía Transesofágica , Fluoroscopía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Enfermedad Iatrogénica/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
J Cardiothorac Vasc Anesth ; 35(1): 208-215, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32732098

RESUMEN

OBJECTIVE: Currently available 3-dimensional (3D) modeling and printing techniques allow for the creation of patient-specific models based on 3D medical imaging data. The authors hypothesized that a low-cost, patient-specific, cardiac computed tomography-based phantom, created using desktop 3D printing and casting, would have comparable image quality, accuracy, and usability to an existing commercially available echocardiographic phantom. DESIGN: Blinded comparative study. SETTING: Simulation laboratory at a single academic institution. PARTICIPANTS: Voluntary cardiac anesthesiologists at a single academic institution. INTERVENTIONS: Stage 1 of the study consisted of an online questionnaire in which a set of basic transesophageal echocardiography (TEE) views obtained from the 3D printed phantom and commercial phantom were presented to participants, who had to identify the views and evaluate their fidelity to clinical images on a Likert scale. In stage 2, participants performed an unblinded basic TEE examination on both phantoms. MEASUREMENTS AND MAIN RESULTS: The time needed to acquire each basic view was recorded. Overall usability of the phantoms was assessed through a questionnaire. The participants could recognize most of the views. Fidelity ratings for both phantoms were similar (p < 0.05), with the exception of a midesophageal 2-chamber view that was observed better on the 3D printed phantom. The time required to obtain the views was shorter for the 3D printed phantom, although not statistically significant for most views. The overall user experience was better for the 3D phantom for all categories examined (p < 0.05). CONCLUSIONS: The study suggested that a 3D-printed TEE phantom is comparable with the commercially available one with good usability.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Humanos , Fantasmas de Imagen , Impresión Tridimensional , Tomografía Computarizada por Rayos X
13.
A A Pract ; 14(10): e01288, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32845111

RESUMEN

A 25-year-old patient with a history of aortic stenosis due to presumed bicuspid aortic valve presented for elective aortic valve replacement. Intraoperative transesophageal echocardiography (TEE) revealed a trileaflet aortic valve but detected the presence of a subvalvular membrane. Multiplanar reconstruction of the 3-dimensional (3D) dataset measured a cross-sectional area of 0.8 cm at the level of this subvalvular membrane. Successful resection resulted in relief of the obstruction. Compared with preoperative transthoracic echocardiography, TEE was able to correctly characterize the nature of the stenosis with area determination accurately provided by application of 3D techniques.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Constricción Patológica , Ecocardiografía Transesofágica , Humanos
14.
Best Pract Res Clin Anaesthesiol ; 34(2): 141-152, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32711825

RESUMEN

Oral anticoagulants (OACs) are a class of medications commonly used in the long-term management of patients at risk of thrombosis. They include warfarin and direct oral anticoagulants (DOACs). The aging of the population and improvements in perioperative care have led to an increase in the number of patients on OACs and presenting for different types of elective and emergency surgery. Perioperative management of OACs constitutes a unique challenge. It is based on the quantification of a patient's individual hemorrhagic and thrombotic risk together with the intrinsic surgical bleeding risk. We reviewed current guidelines to define effective discontinuation of OACs, the need for bridging with different anticoagulants, and post-surgery OACs re-initiation. We also discussed the option for acute reversal of anticoagulation.


Asunto(s)
Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Complicaciones Posoperatorias/prevención & control , Guías de Práctica Clínica como Asunto/normas , Cuidados Preoperatorios/normas , Anticoagulantes/efectos adversos , Coagulación Sanguínea/fisiología , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/efectos adversos , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Humanos , Complicaciones Posoperatorias/inducido químicamente , Complicaciones Posoperatorias/etiología , Cuidados Preoperatorios/métodos , Factores de Riesgo , Trombosis/etiología , Trombosis/prevención & control , Warfarina/administración & dosificación , Warfarina/efectos adversos
15.
EuroIntervention ; 16(8): 682-690, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-32597392

RESUMEN

AIMS: The aim of this study was to evaluate the feasibility, efficacy and safety of the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) technique during transcatheter aortic valve implantation (TAVI) in an initial cohort at a single European centre. METHODS AND RESULTS: Between August 2018 and March 2020, BASILICA was attempted in 23 leaflets in 21 consecutive patients undergoing TAVI (age 78±6 years, 52% female). The index procedure was performed for 21 degenerated bioprosthetic leaflets (90%, 9.2±2.6 years after implantation) and two native leaflets (10%). BASILICA was performed for a single leaflet in 19 (90%) patients and for both leaflets in two (10%) patients. The median total procedure time was 82 (interquartile range [IQR] 70-131) minutes, and BASILICA time (sheath-in to laceration) was 45 (IQR 35-67) minutes. A cerebral embolic protection device was used in 20 (95%) patients. BASILICA was feasible in all but one patient (95%) and resulted in effective prevention of coronary obstruction in 19 patients (90%). One patient developed a non-flow-limiting ostial lesion after BASILICA and TAVI, and was treated by additional coronary stenting. No mortality or stroke was observed up to 30 days. CONCLUSIONS: The feasibility, efficacy and safety of BASILICA in this early single-centre experience were consistent with the initial proof-of-concept reports. Further validation by ongoing multicentre registries remains warranted.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Laceraciones , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/prevención & control , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
16.
EuroIntervention ; 16(10): 824-832, 2020 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-32515739

RESUMEN

AIMS: This study sought to characterise the real-world performance and clinical outcomes of the PASCAL system, a leaflet approximation device for transcatheter mitral valve repair. METHODS AND RESULTS: Fifty patients in NYHA Class II-IV despite optimal medical therapy (median age 78.0 years [IQR 74.5-81.0], 52% female, log EuroSCORE 21.6 [IQR 13.2-30.2]) were treated for severe mitral regurgitation (MR) and followed up for one month. Primary and secondary MR was present in 24% and 68% of patients, respectively, with a mixed aetiology observed in 8%. A 1-device strategy was employed in 26/50 patients (52%), a 2-device strategy in 23/50 (46%) patients, and a 3-device strategy in 1/50 (2%) patients. Technical and procedural success was achieved in 100% and 98% of patients, respectively. MR grade ≤1 was observed in 39/50 (78%) patients at discharge, and in 36/46 (78%) patients at one month, with transvalvular gradients remaining ≤5 mmHg in all patients. One device embolisation and one single leaflet device attachment were observed during follow-up. After one month, 73% of patients reported an improvement in NYHA class, and six-minute walk test distance increased by 73±12 m in patients without relevant tricuspid regurgitation. CONCLUSIONS: In a real-world population, the PASCAL device effectively reduces MR and leads to functional improvements on short-term follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Niño , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
18.
J Cardiothorac Vasc Anesth ; 34(2): 512-520, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31668743

RESUMEN

This article reviews fellowship training in adult cardiac, thoracic, and vascular anesthesia and critical care from the perspective of European program initiators and educational leaders in these subspecialties together with current training fellows. Currently, the European Association of Cardiothoracic Anaesthesiology (EACTA) network has 20 certified fellowship positions each year in 10 hosting centers within 7 European countries, with 2 positions outside Europe (São Paulo, Brazil). Since 2009, 42 fellows have completed the fellowship training. The aim of this article is to provide an overview of the rationale, requirements, and contributions of the fellows, in the context of the developmental progression of the EACTA fellowship in adult cardiac, thoracic, and vascular anesthesia and critical care from inception to present. A summary of the program structure, accreditation of host centers, requirements to join the program, teaching and assessment tools, certification, and training requirements in transesophageal electrocardiography is outlined. In addition, a description of the current state of EACTA fellowships across Europe, and a perspective for future steps and challenges to the educational program, is provided.


Asunto(s)
Anestesia , Anestesiología , Adulto , Anestesiología/educación , Brasil , Cuidados Críticos , Educación de Postgrado en Medicina , Europa (Continente) , Becas , Humanos
19.
J Cardiothorac Vasc Anesth ; 34(1): 151-156, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31405722

RESUMEN

OBJECTIVES: The authors aimed to define the incidence of unilateral pulmonary edema (UPE) within the first 24 hours after minimally invasive cardiac surgery without one lung ventilation techniques based on assessment of chest x-rays. DESIGN: A single-center, retrospective, observational study. SETTING: A university-affiliated tertiary care center. PARTICIPANTS: All consecutive patients >18 years old scheduled for elective minimally invasive cardiac surgery through a right-sided anterolateral minithoracotomy between January 2013 and February 2014 were included. MEASUREMENTS AND MAIN RESULTS: All chest x-rays in the first postoperative 24 hours were assessed by an independent radiologist. Perioperative data were compared using the chi-square test for qualitative data. The Student t test and Mann-Whitney U test, as appropriate, were used for quantitative data. The significant variables were entered into a multiple logistic regression analysis for risk assessment. The study comprised 382 patients (239 men/143 women). Of these, 304 (79.6%) showed normal radiologic findings, 72 (18.8%) showed right-sided pulmonary congestion, and 6 (1.6%) showed right-sided pulmonary edema. Preoperative calcium channel blocker therapy (odds ratio [OR] 3.7), preoperative pathologic right pulmonary vein Doppler profile (OR 3.1), and intraoperative uses of catecholamines (OR 3.2) (95% confidence interval) were independent risk factors for the development of UPE after minimally invasive cardiac surgery. CONCLUSIONS: This study showed an incidence of 1.6% of radiologic evident UPE after minimally invasive cardiac surgery. Future prospective studies are needed to validate the effect of the independent risk factors.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Edema Pulmonar , Adolescente , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Humanos , Incidencia , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Edema Pulmonar/diagnóstico por imagen , Edema Pulmonar/epidemiología , Edema Pulmonar/etiología , Estudios Retrospectivos
20.
JACC Cardiovasc Interv ; 12(15): 1423-1434, 2019 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-31326430

RESUMEN

OBJECTIVES: This study sought to examine the impact of chronic right ventricular (RV) volume overload and implications of tricuspid regurgitation (TR) reduction on biventricular function. BACKGROUND: Severe TR is a major determinant of adverse outcomes in advanced heart failure patients. The understanding of TR pathophysiology and implications of correction is still limited. Transcatheter tricuspid edge-to-edge repair (TTVR) is a new treatment option in patients at high surgical risk and provides a unique pathophysiological model without confounding effects of cardiac surgery. METHODS: Twenty-nine patients (78 ± 4 years of age) with severe isolated TR and high surgical risk underwent TTVR using the MitraClip system, and of these 18 underwent repeated cardiac magnetic resonance. Clinical follow-up was realized at 1 and 6 months after the intervention. RESULTS: TR fraction was reduced from 41% to 21% (p < 0.01) without increase in RV afterload (p = 0.52) and RV end-diastolic volume (p < 0.01), and RV stroke volume decreased (p = 0.03), whereas RV effective forward flow increased (p = 0.03). Left ventricular (LV) filling improved with an increase in LV end-diastolic volume (p = 0.01) and LV stroke volume (p = 0.02), leading to an augmentation of cardiac indices (2.2 ± 0.6 l/min/m2 vs. 2.7 ± 0.6 l/min/m2; p < 0.01) with similar results at 6 months follow-up. After TTVR, New York Heart Association functional class significantly improved (p < 0.01), peripheral edema decreased (p = 0.01), and 6-min walk distance increased by 20% and 22% after 1 and 6 months, respectively (p < 0.01). CONCLUSIONS: TTVR reduces chronic RV volume overload without increase in RV afterload, improves RV performance and LV filling, and enhances cardiac output. These changes translate into symptomatic and functional improvement. These implications for biventricular physiology and clinical status are maintained at 6 months follow-up.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Volumen Sistólico , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Función Ventricular Izquierda , Función Ventricular Derecha , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología
SELECCIÓN DE REFERENCIAS